Laserfiche WebLink
APPENDIX C <br />EXHAUST DUCT: <br />GREASE FILTERS or EXTRACTORS: <br />Model <br />in. <br />in.. <br />STATIC PRESSURE: <br />EXHAUST FAN/BLOWER: <br />sp. <br />0.3331,725 <br />at <br />19 PLAN CHECK GUIDE <br />+ <br />+ <br />+ <br />EHD 1&-01 <br />6/28/2022 <br />Manufacturer <br />Exhaust ___ <br />Blower RPM <br />Filters <br />Entrance loss <br />Duct Length <br />Elbows <br />Loss to outside Atmosphere <br />sp <br />sp <br />sp <br />sp <br />sp <br />Total sp <br />MAKE-UP AIR: <br />Fan Manufacturer <br />Model Number <br />CFM <br />Duct size <br />N u mbe r of d u cts <br />Type of opening <br />Number of openings <br />Electrical interlocking switch with exhaust fan <br />0.15 <br />0.042 <br />0.005 <br />0.0325 <br />0.1 <br />0.329 <br />Duct Size ^2 <br />Square feet of duct area <br />Number of ducts <br />Type of Metal <br />Exhaust duct velocity___ <br />(Recommended 1800 FPM) <br />sp (static pressure) <br />inches <br />sq. ft. <br />Manufacturer <br />Type (with handles) <br />Rating: <br />Dimensions: <br />Functional surface area per filter <br />Number of filters to be used: <br />Tota I fi Iter a rea sq. ft. <br />Number of spacers size of spacers: in. x <br />Minimum distance between lowest edge of grease filters and cooking surface: <br />___ Model No.XRUD-099-A <br />CFM at 2-086 <br />Horsepower <br />(1 outlet per 12 feet or fraction thereof) <br />Galvanized prime sheet Gauge 22 <br />519 FPM (CFM divided by sq. ft. of duct) <br />Accurex <br />555 <br />CFM at <br />inches x <br />sp. <br />Square feet of duct area <br />Duct velocity <br />Opening size <br />CFM per opening <br />1.068 <br />I