My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
WORK PLANS
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
W
>
WILCOX
>
2478
>
2900 - Site Mitigation Program
>
PR0548208
>
WORK PLANS
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/12/2026 2:45:08 PM
Creation date
3/12/2026 2:37:36 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2900 - Site Mitigation Program
File Section
WORK PLANS
RECORD_ID
PR0548208
PE
2960 - RWQCB LEAD AGENCY CLEAN UP SITE
FACILITY_ID
FA0027506
FACILITY_NAME
STOCKTON PROPELLER INC.
STREET_NUMBER
2478
Direction
N
STREET_NAME
WILCOX
STREET_TYPE
RD
City
STOCKTON
Zip
95215
APN
10102174
CURRENT_STATUS
Active, billable
QC Status
Approved
Scanner
SJGOV\gmartinez
Supplemental fields
Site Address
2478 N WILCOX RD STOCKTON 95215
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
170
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Stockton Propeller, Inc. - 4 - 10 May 2022 <br /> Order R5-2022-0806 <br /> NuEtch E3 (SP-01) and DeSmut NS3 (SP-02). The results of the <br /> forementioned select samples are presented in Table 1 , below. Samples SP- <br /> 01 , SP-02, and SP-03 were characterized as corrosive and SP-02 was <br /> characterized as toxic (DTSC, 2021 a and 2021 b). <br /> Table 1: Summary of Select Samples Collected by the DTSC from the Pure Solution <br /> Containers and Rinse Water that was Normally Disposed of into the On-Site Septic <br /> System prior to May 2021 <br /> OCI Sample Description Results Exceeding Legal Citation <br /> Sample Hazardous Thresholds <br /> ID <br /> SP-01 Dirty brown/amber liquid from pH - >13.0 Cal. Code <br /> unlabeled container of Regs., tit. 22, <br /> "NuEtch EY solution § 66261.22 <br /> SP-02 Milky white liquid from Soluble Metals, WET Cal. Code <br /> unlabeled container (mg/L) Regs., tit. 22, <br /> of "DeSmut NS3" solution Copper: 99.7 (STLC: § 66262.24 <br /> 25.0) <br /> Cal. Code <br /> TCLP (mg/L) Regs., tit. 22, <br /> Cadmium: 2.45 § 66261.22 <br /> (Threshold: 1.0) <br /> pH-<1 .0 <br /> SP-03 Cloudy clear liquid from pH - <1.46 Cal. Code <br /> container labeled "Non- Regs., tit. 22, <br /> Hazardous Industrial Waste, § 66261.22 <br /> Rinse Water" <br /> SP- Clear yellowish liquid from a No Exceedances Cal. Code <br /> 10A seven-gallon holding Regs., tit. 22 <br /> container underneath the sink <br /> 9. The DTSC collected additional samples from containers that were improperly <br /> disposed of into the trash or heated to accelerate evaporation of their contents to <br /> the atmosphere (DTSC, 2021 a and 2021 b). These samples were classified as <br /> toxic (SP-04A, SP-05A, SP-07, SP-08, SP-09), reactive (SP-04B), or had no <br /> exceedances (SP-06). <br /> 10.On 9 August 2021, the SJCEHD issued a second Small Quantity Hazardous <br /> Waste Generator Inspection Report, citing a Class I violation for the illegal <br /> disposal of hazardous waste without a permit, as determined by the DTSC's <br /> sampling report (SJCEHD, 2021d). The SJCEHD directed SPI to cease <br /> disposal of all hazardous wastes at unauthorized points. <br />
The URL can be used to link to this page
Your browser does not support the video tag.