Environmental Health Department <br />Telephone: (209) 825-3200 Owner/Operator: MANTECA UNIFIED SCHOOL DISTRICT <br />Inspection Type: Routine <br />Address: 450 E YOSEMITE AVE, MANTECA 95336 <br />Date: 07/17/2025Name of Facility:MUSD-MANTECA HIGH SCHOOL <br />Reinspection on or after: <br />Swimming Pool Official Inspection Report <br />Program Element: 3616 - PUBLIC POOL/SPA - EXEMPT <br />Items listed on this report as violations do not meet the requirements set forth in the California Health and Safety Code section(s) 116043, 116040, & <br />116050. All violations must be corrected within specified timeframe. Violations that are classified as "MAJOR" pose an immediate threat to public <br />health and must be corrected immediately or be subject to closure pursuant to California Code of Regulations (Title 22) section 65545. <br />VIOLATIONS AND CORRECTIVE ACTIONS <br /> #10 Disinfectant Residual <br />OBSERVATIONS: Free chlorine is at 0.4ppm. Provide free chlorine 1ppm - 10ppm. Correct today. <br />Later free chlorine rechecked and it is at 1 ppm. Corrected on site. <br />***Cyanuric acid is not used. Free chlorine is 1ppm - 10ppm.**** <br />CALCODE DESCRIPTION: Public pools, when open or in use, shall be disinfected continuously by approved chemicals and shall <br />maintain the following concentrations: 1.0 ppm to 10.0 ppm free chlorine without cyanuric acid, 2.0 ppm to 10.0 ppm free chlorine with <br />cyanuric acid or 2.0 ppm bromine. Spas, wading pools, and spray grounds shall maintain the following concentrations: 3.0 ppm to <br />10.0 ppm free chlorine or 4.0 ppm bromine. (CCR 65529) <br />This is (Major) Violation. <br />MAJOR <br /> #9 Ladders and Handrails <br />OBSERVATIONS: One of the single handrails and one of the double handrails are not properly secured. Secure handrails in 1 <br />week. <br />CALCODE DESCRIPTION: A means of entry and exit shall be provided at both the shallow and deep end of the pool. Ladders and <br />handrails shall be corrosion resistant and shall be rigidly installed. At least one handrail shall extend from the deck to not less than a <br />point above the top of the lowest step. Handrails shall be installed between 28 to 36 inches above the steps and deck. (CBC 3111B) <br />Pool operator shall keep ladders and handrails well maintained. (CCR 65535) <br />This is (Minor - Food) Violation. <br />OVERALL INSPECTION NOTES AND COMMENTS <br />OBSERVATIONS <br />Flow rate:gpm <br />pH: <br />Chlorine:ppm <br />Cyanuric acid:ppm <br />Temp:º F <br />Combined chlorine:ppm7.4 <br />0.4 <br />NO <br />1066 <br />NOTES <br />Page 1 of 2EHD 36-01 Rev. 09/16/2020 Swimming Pool OIR <br /> PR0360079 07/17/2025 <br />1868 E. Hazelton Avenue | Stockton, California 95205 | T 209 468-3420 | F 209 464-0138 | www.sjgov.org/EHD