My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
SU-2601180_SSNL
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
H
>
HAM
>
11808
>
2600 - Land Use Program
>
SU-2601180_SSNL
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/19/2026 9:55:36 AM
Creation date
3/19/2026 9:50:43 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2600 - Land Use Program
FileName_PostFix
SSNL
RECORD_ID
SU-2601180
PE
2602 - SOIL SUITABILITY AND NITRATE LOADING STUDY REVIEW
STREET_NUMBER
11808
Direction
N
STREET_NAME
HAM
STREET_TYPE
LN
City
LODI
Zip
95240
APN
05923012
CURRENT_STATUS
In Review
QC Status
Approved
Scanner
SJGOV\gmartinez
Supplemental fields
Site Address
11808 N HAM LN LODI 95240
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
79
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
feet. When necessary after measuring the water level, the hole was refilled with water <br /> to a level of approximately six inches above the bottom of the hole. <br /> Percolation Test Results <br /> The completed percolation test form is included in Appendix 3 of this report. The form <br /> was signed by Mr. Gooderham and indicates a percolation rate for the hole based on <br /> the final water drop observed. <br /> Per San Joaquin County Environmental Health Department's definition, a shallow <br /> percolation test hole has a depth between 18 and 42 inches; a satisfactory percolation <br /> rate for a shallow test is greater than or equal to 1 minute per inch (min/in) but less than <br /> or equal to 60 min/in drop. For the Site to utilize a standard septic system, one <br /> percolation test must demonstrate a satisfactory percolation rate within the proposed <br /> septic system disposal field. <br /> Details and results of the percolation testing are summarized in the following table. <br /> Table 2. Percolation Test Summary <br /> Test No., Percolation Test Percolation Rate Test Duration Comments <br /> Date Tested Depth (ft.) (minutes/inch) (see notes) <br /> P1 <br /> ry <br /> 2/3/26 2.01 13.9 4 hr. erc. rate'p <br /> Shallow Test erc. rate <br /> Note: A satisfactory percolation rate for a "shallow"test is greater than 1 but less than or equal to 60 minutes per <br /> inch. <br /> 1 Per San Joaquin County Environmental Health Department, a rate between 5.0 and 30.0 min/in requires an <br /> 8-foot separation between the bottom of dispersal system and ground water, or mitigation by system <br /> design or enhancement. <br /> Discussion of Percolation Test Results <br /> The soils near the proposed septic disposal area for the new ADU have demonstrated a <br /> satisfactory percolation rate for the use of a standard septic system in accordance with <br /> the requirements of the San Joaquin County Environmental Health Department. The <br /> percolation test is considered representative of soils within a 100-foot radius of the test <br /> location. <br /> Discussion of Septic System Sizing <br /> Septic system construction should follow the San Joaquin County On-Site Wastewater <br /> Treatment Systems Standards (2017) where applicable. In this area, most septic <br /> systems utilize leach lines with seepage pits. <br /> LOGE 2605 Page 7 <br />
The URL can be used to link to this page