My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2026
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
A
>
AUSTIN
>
9999
>
4400 - Solid Waste Program
>
PR0440005
>
COMPLIANCE INFO_2026
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/6/2026 12:25:39 PM
Creation date
3/20/2026 3:12:51 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
4400 - Solid Waste Program
File Section
COMPLIANCE INFO
FileName_PostFix
2026
RECORD_ID
PR0440005
PE
4433 - LANDFILL DISPOSAL SITE
FACILITY_ID
FA0004516
FACILITY_NAME
FORWARD DISPOSAL SITE
STREET_NUMBER
9999
STREET_NAME
AUSTIN
STREET_TYPE
RD
City
MANTECA
Zip
95336
APN
201060013, 5
CURRENT_STATUS
Active, billable
QC Status
Approved
Scanner
SJGOV\kblackwell
Supplemental fields
Site Address
9999 AUSTIN RD MANTECA 95336
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
2563
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Brendan Kenny <br /> Central Valley Regional Water Quality Control Board <br /> April 15, 2026 <br /> Remediation Systems Operations and Performance Summary <br /> CAO Task 9.a indicates that quarterly program updates shall include information on remedial systems during <br /> each reporting period. A summary of the Site's GWTS, residential GWTSs, and the facility's landfill GCCS are <br /> provided in this Program Update. Additional details regarding the Site's GWTS (submitted by April 30, 2026) and <br /> the residential GWTSs (submitted by May 1, 2026) are provided under separate cover in the following reports: <br /> • First Quarter 2026 Groundwater Treatment System Monitoring Report; and <br /> • First Quarter 2026 Residential Groundwater Treatment Systems Monitoring Report. <br /> Groundwater Extraction and Treatment System <br /> A GWTS is operated at the Site to address detections of volatile organic compounds (VOCs) in groundwater in <br /> accordance with the WDRs outlined in the Order. The California State Water Resources Control Board Monitoring <br /> and Reporting Program (MRP)Table 19 lists six groundwater extraction wells as part of the GWTS (EW-1, EW-2, <br /> EW-3R, EW-4, EW-5, and CDCR-EW-1). Five of the six groundwater extraction wells listed in Table 19 of the <br /> MRP (EW-1, EW-2, EW-3R, EW-4, and EW-5) are monitored bi-weekly, as they are the only extraction wells that <br /> are part of an operational system. Extraction well CDCR-EW-1 is not currently part of an operational remedial <br /> system and therefore is not monitored bi-weekly. Additional offsite extraction wells (CDCR-EW-2, CDCR-EW-3, <br /> CDCR-EW-4, and CDCR-EW-5)are not included in the MRP and not connected to an operational remedial <br /> system. Due to absence of an operational remedial system at the five offsite extraction wells, the wells are not <br /> monitored bi-weekly as part of the corrective action program. The five offsite extraction wells were added to the <br /> routine quarterly monitoring program in the second quarter of 2025 and are suggested to be included in the next <br /> revision of the MRP. <br /> The extracted groundwater is treated by two, 10,000-pound granulated activated carbon (GAC)vessels that were <br /> installed in January 2020. <br /> During the reporting period, the GWTS was inspected and monitored bi-weekly by Del-Tech Geotechnical <br /> Support(Del-Tech)of Oakdale, California. Flow rates from the extraction wells were routinely monitored and <br /> adjusted, if needed, to confirm groundwater capture within the treatment area. Del-Tech's field inspection forms <br /> are included in Attachment 1. <br /> During the first quarter, the GWTS treated approximately 53,799,794 gallons of extracted groundwater, which <br /> represents an average total flow rate of approximately 689,741 gallons per day. Based on the extracted volumes <br /> and analytical VOC concentrations, the GWTS removed approximately 0.82 pounds of total VOCs during the <br /> reporting period. Del-Tech's downtime log for the reporting period is included in Attachment 1. The GWTS was <br /> operational throughout the reporting period with no downtime events, which indicates the system was operational <br /> for 100 percent of the time (a total of 2,040 hours of system operation between the beginning of the reporting <br /> period through the final visit of the quarter on March 26, 2026). <br /> Total VOCs (up to 0.63 micrograms per liter of total VOCs)were detected in the six system influent samples <br /> collected. No VOCs were detected above the practical quantitation limit in any of the system effluent samples <br /> collected at the point of compliance, satisfying the discharge requirements of the Order. <br /> www.arcadis.com 2/4 <br /> Forward Landfill 1Q26 CAP Update_04.15.2026 <br />
The URL can be used to link to this page
Your browser does not support the video tag.