My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_JTD 2/11/26
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
H
>
HARNEY
>
17720
>
4400 - Solid Waste Program
>
PR0440058
>
COMPLIANCE INFO_JTD 2/11/26
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/25/2026 10:17:41 AM
Creation date
3/24/2026 4:20:07 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
4400 - Solid Waste Program
File Section
COMPLIANCE INFO
FileName_PostFix
JTD 2/11/26
RECORD_ID
PR0440058
PE
4433 - LANDFILL DISPOSAL SITE
FACILITY_ID
FA0004518
FACILITY_NAME
NORTH COUNTY LANDFILL
STREET_NUMBER
17720
Direction
E
STREET_NAME
HARNEY
STREET_TYPE
LN
City
LODI
Zip
95240
APN
06512004
CURRENT_STATUS
Active, billable
QC Status
Approved
Scanner
SJGOV\kblackwell
Supplemental fields
Site Address
17720 E HARNEY LN LODI 95240
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
1799
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
WASTE DISCHARGE REQUIREMENTS ORDER NO. R5-2010-0016 -13- SAN JOAQUIN COUNTY DEPARTMENT OF PUBLIC WORKS NORTH COUNTY LANDFILL SAN JOAQUIN COUNTY <br /> <br /> Title 27 standards (56.2 gal/min and 145.8 gal/min, equal to twice the computed anticipated peak leachate flow rates). The results of site-specific unsaturated zone modeling (using V-Leach software) based on the above data indicated concentrations in groundwater below laboratory detection limits (i.e., < 1.0 μg/L) for all modeled constituents after 100 years. 51. Previous WDRs Order No. R5-2002-0219 approved the above EAD for Module 4 and future modules. Module 4 was constructed in 2004 consistent with the approved EAD and LCRS design. Construction of the module was documented in the November 2003 report Final Construction Quality Assurance Report for Module <br />4 at the North County Recycling Center and Sanitary Landfill, prepared by Vector Engineering, Inc. <br />Grading and Drainage <br />52. Modules 1 through 4 included the following grading features: <br />a. 3H:1V interior excavation slopes; b. 3H:1V exterior slopes; c. Side slope benching every 50 vertical feet (20-foot wide benches). 53. Precipitation and drainage controls installed on the modules included: <br />a. Top decks graded at 5% minimum for drainage. b. Soil berms along top deck perimeter to direct runoff to corner drop inlets. c. Overside (O/S) drains to capture top deck and side slope bench runoff. d. Side slope benches graded at 2% with central “V” drains to intercept and convey runoff to O/S drains. e. Soil berms and outboard ditch within 100-foot setback area along east, west, and south site perimeter to divert run-on and convey runoff to natural drains. 54. Runoff from the landfill is handled as follows: <br />a. Inactive modules (i.e., M1, northern portion of M3) - runoff directed east into ISB ditch system. b. Active modules (i.e., M4, southern portion of M3) - runoff directed south to temporary pond in future Module 5 and 6 excavation areas. c. Future Module 5 and 6 areas - water from excavation area periodically pumped out to ditch that flows to ISB. d. Future Modules 7 through 11 areas – Runoff from these areas either flows directly to the ISB ditch system, or collects in low areas and is pumped into the ISB ditch system as part of site maintenance. The ISB ditch system drains to ISB.
The URL can be used to link to this page
Your browser does not support the video tag.