Laserfiche WebLink
S A N J O A Q U I N AMENDED Environmental Health Department <br /> COUNTY 6/12/2025 <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> EXPRESS FUEL& MART 1701 E DR MARTIN LUTHER KING JR BLVD STO June 11 2025 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 7 CA Code of Regulations 2715(a)(1)(B), 2715(a)(3) 2010003 - Owner/Operator submitted DO form and/or informed the <br /> CUPA of <br /> OBSERVATION: A new designated operator, Alex Jabbari, began conducting inspections and notification was not <br /> provided to the EHD within 30 days of the ch ng�y <br /> REGULATION GUIDANCE:The owner or operator shall submit a"Designated Underground Storage Tank Operator <br /> Identification Form" no later than 30 days after any change in the d a or(s). <br /> CORRECTIVE ACTION: Immediately log into the California Environmental Reporting System (CERS) at <br /> http://cers.calepa.ca.gov and upload the notification identifying all the designated operators for this facility. <br /> This is a Repeat (Class 2) Violation. <br /> 10 CA Code of Regulations 2638(c), 2638(d) 2030074- Annual Monitoring System Certification Form to the CUPA within <br /> 30 days of completion of the test <br /> OBSERVATION: A monitoring system certification and leak detector testing was performed on 6/4/24. A test report has <br /> not been submitted to the EHD or the California Environmental Reporting System (CERS). <br /> REGULATION GUIDANCE:A copy of the test report must be submitted within 30 days of the test. <br /> CORRECTIVE ACTION: Immediately provide this report to the EHD. <br /> This is a Repeat(Class 2) Violation. <br /> 13 CA Code of Regulations 2637.1(d), 2637.1(e) 2010017- Spill bucket testing results submitted to the UPA within 30 <br /> days of testing <br /> OBSERVATION: Spill container testing was performed on 6/4/24. A test report has not been submitted to the EHD or the <br /> California Environmental Reporting System (CERS). <br /> REGULATION GUIDANCE: A copy of the test report must be submitted within 30 days of the test. <br /> CORRECTIVE ACTION: Immediately provide this report to the EHD. <br /> This is a Repeat (Class 2) Violation. <br /> 14 CA Code of Regulations 2637.2(d&e), 2665(a&b) 2010018 - Overfill prevention equipment inspection report form <br /> submitted to the UPA within 30 days <br /> E OBSERVATION: An overfill prevention equipment inspection was scheduled to be performed on 6/4/24. A test report <br /> has not been submitted to the EHD or the California Environmental Reporting System (CERS). No record of testing was <br /> observed on site. <br /> REGULATION GUIDANCE: Secondary containment testing is required once every 36 months. A copy of the test report <br /> must be submitted within 30 days of the test. <br /> CORRECTIVE ACTION: Immediately schedule this test and provide 48 hours notification to the EHD. <br /> This is a Repeat (Class 2) Violation. <br /> EHD-CUPA Inspection Report IS02 Page 5 of 7 FA0002512 PR0231059 4516502 6/12/2025 <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjgov.org/EHD <br />