My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
SU-2601231_SSNL
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
B
>
BUTLER
>
22120
>
2600 - Land Use Program
>
SU-2601231_SSNL
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/9/2026 2:54:49 PM
Creation date
4/9/2026 2:51:27 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2600 - Land Use Program
FileName_PostFix
SSNL
RECORD_ID
SU-2601231
PE
2602 - SOIL SUITABILITY AND NITRATE LOADING STUDY REVIEW
STREET_NUMBER
22120
Direction
E
STREET_NAME
BUTLER
STREET_TYPE
LN
City
LINDEN
Zip
95236
APN
09303062
CURRENT_STATUS
In Review
QC Status
Approved
Scanner
SJGOV\gmartinez
Supplemental fields
Site Address
22120 E BUTLER LN LINDEN 95236
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
81
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
but less than or equal to 30 min/in drop. For the Site to utilize a standard septic system, <br /> one percolation test must demonstrate a satisfactory percolation rate within the <br /> proposed septic system disposal field. <br /> Details and results of the percolation testing are summarized in the following table. <br /> Table 2. Percolation Test Summary <br /> Test No., Percolation Test Percolation Rate Test Duration Comments <br /> Date Tested Depth (ft.) (minutes/inch) (see notes) <br /> Pi-S Satisfactory <br /> 2/26/26 1.84 22.7 4 hr. <br /> Shallow Test perc. rate <br /> P1-D Satisfactory <br /> 2/26/26 7.64 2.03 1 hr. perc. rate <br /> Deep Test <br /> Note: A satisfactory percolation rate for a "shallow" test is greater than 1 but less than or equal to 60 min/in. A <br /> satisfactory percolation rate for a"deep"test is greater than 1 but less than or equal to 60 min/in. <br /> 1 Per San Joaquin County Environmental Health Department, a rate between 5.0 and 30.0 min/in requires an <br /> 8-foot separation between the bottom of dispersal system and ground water, or mitigation by system <br /> design or enhancement. <br /> 2 Per San Joaquin County Environmental Health Department, a rate between 1.0 and 5.0 min/in requires an <br /> 8-foot separation between the bottom of dispersal system and ground water, or mitigation by system <br /> design or enhancement. <br /> Discussion of Percolation Test Results <br /> The soils near the proposed septic disposal area for the new ADU have demonstrated <br /> satisfactory percolation rates for the use of a standard septic system in accordance with <br /> the requirements of the San Joaquin County Environmental Health Department. The <br /> percolation test is considered representative of soils within a 100-foot radius of the test <br /> location. <br /> Discussion of Septic System Sizing <br /> Septic system construction should follow the San Joaquin County On-Site Wastewater <br /> Treatment Systems Standards (2017) where applicable. In this area, most septic <br /> systems utilize leach lines with seepage pits. <br /> LOGE 2611 Page 7 <br />
The URL can be used to link to this page
Your browser does not support the video tag.