Laserfiche WebLink
.......................................................................................................................................................................... <br /> ; STORAGE/TRANSPORT OF IDW* ❑Describe site-specific procedures above for spill containment,container handling,as applicable. <br /> Spill/Release Risk: ❑For liquids,provide secondary containment during storage. <br /> ❑Risk of incidental spill/release ❑Segregate incompatible chemicals during storage. <br /> ❑Risk of emergency spill/release ❑Locate emergency gear(eyewash,fire extinguisher,spill kit,safety signage)near storage area,as applicable. <br /> ❑For incidental spills;spill kit on-site for low-hazard releases(low-flammability/toxicity/quantity/volatility) <br /> *Investigation Derived Waste ❑For emergency spills:describe spill/release hazard and response plan/procedure above,and indicate <br /> Emergency response contact in Part B,"Emergency Response and First Aid." <br /> ❑DOT/TDG/IATA-Regulated transport:see D.17."Hazmat/Dangerous Goods Shipping/Transportation." <br /> Geosyntec Procedures: HS-406-Unknown Hazardous Waste Drum Handling <br /> OFF-SITE MIGRATION OF AIRBORNE 1 ❑Implement controls to minimize hazard migration(dust suppression,covers,foam,etc.). <br /> CONTAMINANTS ❑Community/perimeter air monitoring to be conducted per perimeter air monitoring plan;see E.3"Fence <br /> Line/Perimeter Air Monitoring." <br /> D.16. RADIATION HAZARDS(Other than Sunlight) 1-1 Applicable ® Not Applicable, Not Anticipated <br /> Site-Specific Notes&Clarifications: <br /> IONIZING Potential hazard sources may include nuclear density gauges,host-facility X-ray equipment,radioactive contaminants(a,(3,7), <br /> RADIATION medical or laboratory waste. Describe hazards&safety measures above in Site-Specific Notes&Clarifications. Conduct exposure <br /> monitoring,as appropriate;see Part E,"Air Monitoring,Worker Exposure Monitoring." <br /> Geosyntec Procedures: HS-126-Radiation Safety Program,HS-128-Ionizing and Non-Ionizing Radiation <br /> El NON-IONIZING Potential hazard sources may include lasers,UV/IR sources,microwaves&high-frequency radio waves from cell-phone transmitter, <br /> RADIATION high-intensity visible light. Describe hazards&safety measures above in Site-Specific Notes&Clarifications. Conduct exposure <br /> monitoring,as appropriate;see Part E,"Air Monitoring,Worker Exposure Monitoring." <br /> Geosyntec Procedures: HS-128-Ionizing and Non-Ionizing Radiation <br /> D.17. HAZMAT/DANGEROUS GOODS SHIPPING/TRANSPORTATION F Applicable ® Not Applicable, Not Anticipated <br /> MODE(S)OF TRANSPORT: ❑Road ❑Rail El Air ❑Sea ❑Inland Waterway ❑International <br /> IMPORTANT:Ensure that each individual who will be involved in shipping/transportation of hazardous material is current with required training(awareness,function- <br /> specific,safety,security)in accordance with applicable regulatory authority(DOT,FAA,IATA,TDG),and ensure adherence to applicable regulations. <br /> Geosyntec Procedures: HS-135-Hazardous Materials Procedures <br /> Site-Specific Notes&Clarifications: <br /> PART E-AIR MONITORING, WORKER EXPOSURE MONITORING <br /> E.I. AIR MONITORING ❑ Applicable ® Not Applicable, Not Anticipated <br /> Site-Specific Notes,Clarifications: <br /> AIR-TESTING PARAMETERS-Select site-specific testing parameters;list associated equipment in Part C.2,Safety Equipment List. <br /> E]VOCs E]Oxygen(02)—oxygen meter ❑Particulates total dust meter <br /> ❑Photoionization detector(PID): X eV ❑Lower Explosive Level(LEL)-LEL meter ❑%Methane—methane meter <br /> ❑Flame ionization detector(FID) ❑Hydrogen sulfide(H2S)—H2S detector ❑Calibration kit for each parameter <br /> ❑Calorimetricindicatortubes—describeabove ❑Carbon monoxide(CO)—CO detector ❑Other: <br /> SUBSTANCE-SPECIFIC(PRE-SET)ACTION LEVELS-Sustained breathing zone action levels(sustained general work-area levels for LEL). <br /> 19.5-23% Acceptable to continue work without 02-focused respiratory protection. <br /> O .......................................................................................<...................................................................................................................................................................................................................................................................................................................................................................................... <br /> ❑ 2 <19.5% STOP WORK,ventilate to raise 02 to>19.5%for re-entry. For persistent hazard,contact Corp.H&S Dept. <br /> (Oxygen)Ox en .......................................................................................<.............. <br /> >23.0% STOP WORK,ventilate to lower 02 to<23%for re-entry. For persistent hazard,contact Corp.H&S Dept. <br /> IMPORTANT: Confirm sufficient oxygen is present(min.8-12%)to ensure accurate LEL readings. <br /> .............. .........................;........ ................................ .................................................................................................. <br /> LEL(Lower <10%LEL Acceptable to continue working in work area;continue to monitor LEL. <br /> ❑ ......................................................................................................................................................................................................................................................................................................................................... .................... .................. <br /> Explosive Limit) STOP WORK. Implement controls(reposition workers,ventilate,contain/eliminate source,etc.);resume <br /> >10%LEL work ONLY when LEL readings are<10%,sustained. <br /> <1 ppm Acceptable to continue work without H2S-focused respiratory protection. <br /> I.......................................................................................:...................................................................................................................................................................................................................................................................................................................................................................................... <br /> Implement controls(reposition workers,ventilate,contain/eliminate source,scheduling,etc.)to limit <br /> 1-10 ppm exposures to<1ppm,or use APR*with VOC/acid-gas cartridges(yellow);do not exceed MUC*for respirator <br /> H <br /> zS <br /> ❑ i....................................................................................... <br /> type;confirm acceptability of respirator usage with Corp.H&S Dept.(Hydrogen Sulfide <br /> Implement controls(reposition workers,ventilate,contain/eliminate source,scheduling,etc.)to limit <br /> >10 ppm exposures to<10ppm(with respirator),or<1ppm(without respirator). For persistent levels>10 ppm,STOP <br /> WORK,contact Corp.H&S Dept. <br /> <25 ppm Acceptable to continue work without CO-focused respiratory protection. <br /> CO .............................. .............;...................................................................................................................................................................................................................................................................................................................................................................................... <br /> ❑ (Carbon Monoxide) >25 ppm Implement controls(reposition workers,ventilate,contain/eliminate source,scheduling,etc.)to limit <br /> exposures to<25ppm. For persistent levels>25ppm,STOP WORK,contact Corp.H&S Dept. <br /> Project/Task Name: <br /> Geosynteccl THA Date: Page 12 <br /> consultants <br />