Laserfiche WebLink
Table 2 <br /> Well Destruction Evaluation <br /> Lincoln Center <br /> Stockton,California <br /> Preliminary Well Destruction Selection Criteria <br /> Well Screened Zone Located within remedy Used for remedy performance Provides groundwater flow information Will destruction activities impact wells <br /> Assessemnt In MRP/GWMP? Defines plume extent boundary? Destroy Well? <br /> footprint? evaluation? relevant to remedy? used for remedy assessment? <br /> PZ-OOIA A Yes No No No NO No See below <br /> PZ-002A-1 A No No No No No No Yes <br /> PZ-002A-2 A No No No No No No Yes <br /> Piezometers located PZ-003A A No No No No No No Yes <br /> near edge of PZ-004A A Yes No No No No No See below <br /> monitoring network PZ-005A-1 A Yes No No No No No See below <br /> PZ-005A-2 A No No No No No No Yes <br /> PZ-011A A Yes No No No No No See below <br /> PZ-012A-1 A Yes No No No No No See below <br /> PZ-012A-2 A Yes No No No No No See below <br /> MW-OOIA A No No No No No No Yes <br /> MW-005A A No No No No No No Yes <br /> Wells previously MW-103A A No No No No No No Yes <br /> identified for MW-104A A No No No No No No Yes <br /> destruction(2020 MW-105A A No No No No No No Yes <br /> Request) MW-110A A No No No No No No Yes <br /> MW-111A A No No No No No No Yes <br /> MW-204B B No No No No No No Yes <br /> ERD-01 A/B No No Yes No No No See below <br /> ERD-02 A No No Yes No No No See below <br /> ERD-03 A/B No No Yes No No No See below <br /> ERD-04 A No No Yes No No No See below <br /> ERD-05 A No No Yes No No No See below <br /> ERD-06 A/B No No Yes No No No See below <br /> ERD-07 A No No Yes No No No See below <br /> ERD-08 A/B No No Yes No No No See below <br /> ERD-09 A/B No No Yes No No No See below <br /> ERD-10 A No No Yes No No No See below <br /> Well previously used ERD-11 A/B No No Yes No No No See below <br /> for ERD injections ERD-12 A No No Yes No No No See below <br /> ERD-13 A No No Yes No No No See below <br /> ERD-14 A No No Yes No No No See below <br /> ERD-15 A No No Yes No No No See below <br /> ERD-16 A No No Yes No No No See below <br /> ERD-17 A No No Yes No No No See below <br /> ERD-18 A No No Yes No No No See below <br /> ERD-19 A No No Yes No No No See below <br /> ERD-20 A No No Yes No No No See below <br /> ERD-21 A No No Yes No No NO See below <br /> ERD-22 A No No Yes No No No See below <br /> Preliminary If well is located within the remedyfoot rint and/or included in MRP/GWMP: <br /> Well Screened Zone Low or below MCL COC trends or not The well is damaged or <br /> ASSOSSemnt Is well redundant? monitored?' fouled?' <br /> Destroy Well? <br /> PZ-OOIA A No Yes No Yes <br /> Piezometers located PZ-004A A Yes Yes No Yes <br /> near edge of monitoring PZ-005A-1 A Yes Yes No Yes <br /> network PZ-011A A Yes Yes No Yes <br /> PZ-012A-1 A No Yes No Yes <br /> PZ-012A-2 A No Yes No Yes <br /> ERD-01 A/B No Yes No Yes <br /> ERD-02 A No Yes No Yes <br /> ERD-03 A/B No Yes No Yes <br /> ERD-04 A No Yes No Yes <br /> ERD-05 A No Yes No Yes <br /> ERD-06 A/B No Yes No Yes <br /> ERD-07 A No Yes No Yes <br /> ERD-08 A/B No Yes No Yes <br /> ERD-09 A/B No Yes No Yes <br /> ERD-10 A No Yes No Yes <br /> Well previously used ERD-11 A/B Yes Yes No Yes <br /> for ERD injections ERD-12 A Yes Yes No Yes <br /> ERD-13 A Yes Yes No Yes <br /> ERD-14 A Yes Yes No Yes <br /> ERD-15 A Yes Yes No Yes <br /> ERD-16 A Yes Yes No Yes <br /> ERD-17 A Yes Yes No Yes <br /> ERD-18 A Yes Yes No Yes <br /> ERD-19 A Yes Yes No Yes <br /> ERD-20 A Yes Yes No Yes <br /> ERD-21 A Yes Yes No Yes <br /> rE��ERD-22 A Yes Yes No Yes <br /> Notes: <br /> GWMP Sitewide Groundwater Monitoring and Reporting Plan(ERM,2015) <br /> MRP Monitoring and Reporting Program R5-2015-0012-013 issued May 30,2022 <br /> COCs Constituents of conccm <br /> The remedy footprint is defined as any well located within the treatment zone.Per General Waste <br /> 1 Discharge Requirement MRP guidance,the extent of the treatment zone is where In Situ Chemical <br /> Oxidation has been or is proposed to be applied <br /> 2 Low or below MCL COC concentrations for approximately 2 years. <br /> 3 Well is damaged or fouled beyond repair. <br />