Laserfiche WebLink
Phase II Sampling and Analysis Plan SOP-2—Drilling and Sampling <br /> Port of Stockton-Rail and Bridge,Stockton,CA FN <br /> 6.2.3.4 Soil Sample Collection for Laboratory Analysis <br /> Selected soil samples will be collected for laboratory analysis at the depths specified in the work <br /> plan or field observations. At these selected locations, samples for volatile organic compound (VOC) <br /> analysis will be collected using a Terracore sampler, or an acceptable equivalent. Samples collected <br /> for VOC analysis should be collected from the soil cores in a manner that minimizes disturbance of <br /> the sample. <br /> The following items should be considered when collecting soil samples: <br /> • A clean pair of new, non-powdered, disposable gloves will be worn each time a sample is <br /> collected. <br /> • Personnel must use new Terracore samplers for each sample interval. <br /> • Document field sampling, including field conditions, problems encountered during sampling <br /> and sample appearance, in the field form. Samples collected will also be noted on the drilling <br /> log sheet at the corresponding depth. <br /> • Place unused sample material into the approved transport/disposal containers along with <br /> other drill cuttings generated during drilling activities. <br /> • When soil sampling is completed or when time permits, transfer samples to the site office for <br /> final packaging. Complete COC documentation and shipping procedures in accordance with <br /> relevant SOPS. The completed COC will remain with the samples until custody is <br /> relinquished. <br /> • Note problems encountered during sampling in the Daily Quality Control Report Form. <br /> 6.2.3.4.1 Terracore Sampler Procedures <br /> The procedure for collection of VOC samples using a Terracore Sampler are as follows: <br /> • Label appropriate laboratory containers. <br /> • Quickly push the sampler(Terracore or equivalent) into a freshly exposed surface of soil to <br /> collect 5 grams (+ 0.5g) of sample. Also collect a bulk aliquot container for moisture content <br /> analysis in the laboratory supplied 4-ounce container. <br /> • Carefully wipe the exterior of the sampler head with a clean disposable paper towel. <br /> • Empty sampler into appropriate laboratory container. The cored samples must be extruded <br /> from the selected coring tool to a volatile organic analysis (VOA)vial in accordance with <br /> collection and preservation methods described in EPA method 5035A. The extruded core is <br /> transferred into a laboratory pre-weighed (tared)VOA vial. The VOA threads should be <br /> wiped with a new paper towel to remove soil and the VOA capped with septum cap. <br /> Preserve VOA vials must be analyzed within 14 days of collection. <br /> • Place the sample into a plastic ZiplocTm bag and place into a cooler with ice. <br /> • Complete COC documentation and shipping procedures in accordance with relevant SOPS. <br /> 2-9 <br />