My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2026
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
N
>
99 (STATE ROUTE 99)
>
24323
>
2200 - Hazardous Waste Program
>
PR0518101
>
COMPLIANCE INFO_2026
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/19/2026 4:20:38 PM
Creation date
5/19/2026 4:18:49 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2200 - Hazardous Waste Program
File Section
COMPLIANCE INFO
FileName_PostFix
2026
RECORD_ID
PR0518101
PE
2220 - SM HW GEN <5 TONS/YR
FACILITY_ID
FA0004345
FACILITY_NAME
JAHANT FOOD N FUEL STOP
STREET_NUMBER
24323
Direction
N
STREET_NAME
STATE ROUTE 99
City
ACAMPO
Zip
95220
APN
00516019
CURRENT_STATUS
Active, billable
QC Status
Approved
Scanner
SJGOV\kblackwell
Supplemental fields
Site Address
24323 N STATE ROUTE 99 ACAMPO 95220
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
11
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Small Quantity Hazardous Waste Generator Program Inspection Report <br />Date: <br />April 29, 2026 <br />Facility Address: <br />24323 N HWY 99, ACAMPOJAHANT FOOD N FUEL STOP <br />Facility Name: <br />Environmental Health Department <br />21 HSC 6.5 25187.6 3040002-Quarantined HW not removed/ transferred/disposed without permission <br />by authorized agent or a court <br />o OUT o R o COS <br />22 22 CCR 12 66262.16(b) <br />(1), 66262.16(b)(8), <br />66262.16(c), 66262.16(g) <br />(1); HSC 6.5 25123.3(c), <br />25123.3(h)(1) <br />3030009-VSQG disposed of waste within 180 days of accumulation start date (90 <br />days for AHW) <br />o OUT o R o COS <br />23 22 CCR 12 66262.16(b) <br />(1), 66262.16(b)(8), <br />66262.16(c), 66262.16(g) <br />(2); HSC 6.5 25123.3(h) <br />(1) <br />3030010-SQG disposed of hazardous waste within 180 days of accumulation start <br />date (90 days for AHW) <br />n OUT o R o COS <br />24 22 CCR 12 66262.15(a)3030057-Met all requirements for hazardous waste satellite accumulation o OUT o R o COS <br />25 22 CCR 12 66262.16(b) <br />(4)(A), 66262.17(a)(5)(A) <br />3030007-Labeled all containers or portable tanks containing hazardous waste n OUT o R o COS <br />26 22 CCR 12 66262.16(b) <br />(2)(A), 66262.15(a)(1) <br />3030013-Accumulated hazardous waste in containers that are in good condition o OUT o R o COS <br />27 22 CCR 12 66262.16(b) <br />(2)(B), 66262.15(a)(2) <br />3030015-Hazardous waste accumulated in lined and/or compatible containers n OUT o R o COS <br />28 22 CCR 12 66262.15(a) <br />(4), 66262.16(b)(2)(C) <br />3030017-Containers of hazardous waste closed except when adding or removing <br />waste <br />o OUT o R o COS <br />29 22 CCR 12 66262.16(b) <br />(2)(D) <br />3030019-Inspects all hazardous waste storage areas at least weekly o OUT o R o COS <br />30 22 CCR 12 66262.15(a) <br />(3), 66262.16(b)(2)(E) <br />3030022-Incompatible waste in containers managed properly to prevent a reaction o OUT o R o COS <br />31 22 CCR 11 66261.7 3030058-Empty containers > 5 gallons properly managed o OUT o R o COS <br />32 22 CCR 12 66262.16(b) <br />(4)(B), 66262.17(a)(5)(B) <br />3030056-Stationary tanks marked with "Hazardous Waste", hazards of waste, and <br />the accumulation start date <br />o OUT o R o COS <br />33 22 CCR 12 66262.16(b) <br />(3)(A)4 <br />3030025-Continuously fed hazardous waste tanks are equipped with an overfill <br />protection device <br />o OUT o R o COS <br />34 22 CCR 12 66262.16(b) <br />(3)(B)1-3 <br />3030027-Daily inspections of the hazardous waste tank systems conducted o OUT o R o COS <br />35 22 CCR 12 66262.16(b) <br />(3)(B)4-5, 66262.16(b)(3) <br />(C) <br />3030028-Weekly inspections of the hazardous waste tank system conducted o OUT o R o COS <br />36 22 CCR 12 66262.16(b) <br />(3)(D) <br />3050007-Removed hazardous waste from tanks, equipment, and discharge <br />confinement structures upon closure <br />o OUT o R o COS <br />37 22 CCR 12 66262.16(b) <br />(3)(A)3 <br />3030024-Uncovered hazardous waste tanks have 2 feet of freeboard unless <br />equipped with adequate containment <br />o OUT o R o COS <br />38 HSC 6.5 25143.2, <br />25143.9 <br />3050005-Recyclable material is managed properly o OUT o R o COS <br />39 HSC 6.5 25250.7(a)3050004-Generator does not intentionally contaminate used oil with other <br />hazardous wastes <br />o OUT o R o COS <br />40 22 CCR 16 66266.130; <br />HSC 6.5 25250.22 <br />3030004-Properly manages used oil filters and fuel filters o OUT o R o COS <br />41 22 CCR 16 66266.81(a) <br />(1) <br />3030001-Meets requirements for handling/storing/transporting lead acid batteries o OUT o R o COS <br />42 22 CCR 16 66266.81(a) <br />(3) <br />3030002-Meets all requirements when accepting spent lead-acid batteries o OUT o R o COS <br />43 22 CCR 16 66266.81(b)3030003-Properly manages, stores and labels all damaged lead-acid batteries o OUT o R o COS <br />44 HSC 6.5 25211.4 3010033-Obtained Certified Appliance Recycler certification (CAR) from the DTSC o OUT o R o COS <br />45 HSC 6.5 25212 3030055-CAR properly managed all MSRH as hazardous waste o OUT o R o COS <br />1868 E. Hazelton Avenue | Stockton, California 95205 | T 209 468-3420 | F 209 464-0138 | www.sjgov.org/EHD <br />Page 2 of 4EHD - CUPA Inspection Report IS03 <br />CP25 - HW SQG <br />4/30/2026FA0004345 PR0518101 4642740
The URL can be used to link to this page
Your browser does not support the video tag.