Laserfiche WebLink
Compostable Materials Handling Operation and Facility Inspection <br /> Report (93) <br /> Central Valley Compost (39-AA-0051) <br /> 9/14/2026 <br /> NOTES: <br /> 1. Litter on site was light. Litter observed in two of the ditches, staff observed cleaning litter. <br /> Litter was not observed on neighboring properties. <br /> 2. Track out was light. The sweeper comes once a day in the afternoon to sweep Frewert Rd., <br /> per operator. <br /> 3. Fly bait stations observed throughout the facility. No fly issues observed. <br /> 4. The second quarter S131 383 measurement has not been provided. The S131 383 <br /> measurements are due 30 days after the end of the quarter. <br /> 5. Records received by email. Records include tonnage, vehicle count, special occurrence, <br /> sampling results and temperature logs. <br /> 6. Odor was light. <br /> 7. The small opening at the bottom of the fence located near the southern pond has been <br /> repaired. <br /> 8. The following temperatures were measured during the inspection: <br /> - Raw green waste was 92°F <br /> - Ground green waste was 166°F <br /> - Windrows ranged from 154°F to 174°F <br /> - Finished compost was 150°F <br /> - Finished product ranged from 142°F to 158°F <br /> - Biosoil was 132°F <br /> - Overs were 170°F <br /> 9. The weather during the inspection was sunny and the temperature was 67°F with a <br /> southeastern wind of 7 mph. <br /> 10. The temperature for windrow #18 was measured at 174°F and the overs were 170°F. <br /> Operator was made aware. Per operator, the overs will be transported off site by the end of <br /> the day. <br /> CalRecycle Solid Waste Information System (SWIS) Page 2 of 3 <br /> Date Generated: September 16, 2026 2:14 PM <br />