Laserfiche WebLink
Nitrate Loading Calculations: <br /> Variable Value Units Description <br /> Q 350 gallons per day Effluent flow rate from report <br /> Nw 35 mg/L-N Effluent stream concentration from report <br /> A 1.46 acres Site area from report <br /> Nb 0.103 mg/L-N Concentration of rain water from report <br /> d 0.25 constant Denitriflcation factor from report <br /> R 3.83 inches per year Recharge rate of rainfall from report(evapotranspiration method) <br /> W 3.2 inches per year Uniform waste water loading for site calculation result <br /> Nc 12.1 mg/L-N RESULT: Long-term average concentration of percolating effluent <br /> Find Variable(lM: <br /> (W) in = (Q) gal x 1 W x 365 day(s) x 1 acre x 12 in x 1 site <br /> yr day 7.48 gal 1 year 43,560 ft2 1 ft (A)acre(s) <br /> 3.22 in/yr(site)=350 gal/day x(1 cu-ft/7.48 gals)x(365 days/1 year)x(1 acre/43,560 sq-ft)x(12 in/1 ft)x(1 site 11.46 acres) <br /> Hantzsche-Fennemore Equation(Nc: <br /> IN= WN d --d)+RIN <br /> W+R <br /> 12.05 mg/L-N=((3.22 in/yr x 35 mg/L-N x(1-0.25))+(3.83 in/yr x 0.103mg/L-N))/(3.22 in/yr+3.83 in/yr) <br /> Assumptions: <br /> 1. Total nitrogen concentration of influent waste stream is 35 mg/L-N. If different influent concentrations exist,use weighted average <br /> 2. Fraction of nitrate-N loss due to denitrification in the soil is 25%. <br /> 3. Estimated deep percolation of rainfall is 3.83 in/yr. <br /> 4. Background nitrate-N concentration of rainfall is 0.103 mg/L-N. <br /> Nitrate Loading Calculation Plate No.: 16 <br /> ^k- <br /> Anderson Property Project No: 2619 <br /> LIVE OAK 20795&20295 S.Van Allen Rd. Date: April 23,2026 <br /> GEO ENVIRONMENTAL INC. EScalon,CA <br />