Laserfiche WebLink
Cleanup in Vulnerable Communities'Initiative Discovery Project Reference:Favorite Cleaners <br /> and Enforcement Discovery Investigation Work Plan Project Number:60688620 <br /> respective matrix tested. If no valid detectable concentrations of target compounds are reported for the given <br /> samples,then a decision will be made that the Subject Property is adequately characterized with respect to the <br /> compounds tested, and no further sampling will be required as part of this Discovery Investigation. If target <br /> constituents are detected in the samples tested, depending on the data, it may be necessary to perform <br /> additional sampling until the Subject Property is completely characterized.Once the Subject Property is <br /> adequately characterized,the data will be compiled for use in calculating screening risks to human health and <br /> the environment.The results of the risk evaluation will be used to request a determination from DTSC. <br /> • Specify Limits on Decision Error: The results of the analytical testing will be subject to data evaluation <br /> following the procedures for data review specified in Section 4.3 below. Data will be determined to be valid if the <br /> specified limits on precision, accuracy, representativeness, comparability, completeness, and sensitivity are <br /> achieved.The results of any detected target constituents will be considered in evaluating the need for additional <br /> sampling of soil vapor, soil,or groundwater, and assessing the necessity for reducing any risks posed by the <br /> potential contamination.AECOM will review the signed data package from the laboratory and will be responsible <br /> for the quality of the data. <br /> • Develop the Plan for Obtaining Data: The field-sampling program has been designed to provide the type and <br /> quantity of data needed to satisfy each of the aforementioned objectives. Due to the absence of previous <br /> Subject Property investigations(i.e., site characterization and sampling),there is a possibility of constituent hot- <br /> spots being inaccessible for sampling at this time.Areas of high concentration on-site may not be identified <br /> without additional access and investigation of the Subject Property. This Work Plan provides the specifications <br /> for the data collection activities, including the numbers of samples, respective locations, and sampling <br /> techniques.The quality of the data will be assessed through the procedures further described herein. <br /> 4.2 Specific Data Quality Objectives <br /> Specific DQOs for the data quality indicators(DQIs)of precision, accuracy, representativeness, completeness, <br /> comparability, and MDLs have been selected in accordance with USEPA Guidance for the Data Quality Objectives <br /> Process(USEPA 2000). These DQIs and their corresponding DQOs are discussed below. <br /> 4.2.1 Precision <br /> Precision measures the reproducibility of repetitive measurements. It is strictly defined as the degree of mutual <br /> agreement among independent measurements as the result of repeated application of the sample process under <br /> similar conditions. <br /> Analytical precision is a measurement of the variability associated with duplicate or replicate analyses of the same <br /> sample in the laboratory and is determined by analysis of laboratory QC samples, such as duplicate control samples, <br /> MSD,or sample duplicates. If the recoveries of analytes in the specified control samples are comparable within <br /> established control limits,then precision is within limits. <br /> Total precision is a measurement of the variability associated with the entire sampling and analytical process. It is <br /> determined by analysis of duplicate or replicate field samples, and measures variability introduced by both the <br /> laboratory and field operations. Field duplicate samples are analyzed to assess field and analytical precision. <br /> Duplicate results are assessed using the RPD between duplicate measurements. If the RPD for the laboratory QC <br /> samples exceeds 30 percent, data will be qualified. If the RPD between the primary and duplicate field samples <br /> exceeds 50%,data will be qualified.The RPD will be calculated as follows: <br /> RPD =200(X2—Xt)/(X2+Xt), <br /> where Xi is the larger of the two observed values and X2 is the smaller of the two observed values. <br /> 4.2.2 Accuracy <br /> Accuracy is a statistical measurement of correctness and includes components of random error(variability due to <br /> imprecision)and systematic error. It reflects the total error associated with a measurement.A measurement is <br /> accurate when the value reported does not differ from the true value or known concentration of the spike or standard. <br /> Prepared for: California Department of Toxic Substances Control AECOM <br /> 27 <br />