My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
WORK PLANS
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
N
>
NAVY
>
3003
>
2900 - Site Mitigation Program
>
PR0542307
>
WORK PLANS
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/22/2026 3:55:29 PM
Creation date
6/22/2026 3:48:16 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2900 - Site Mitigation Program
File Section
WORK PLANS
RECORD_ID
PR0542307
PE
2960 - RWQCB LEAD AGENCY CLEAN UP SITE
FACILITY_ID
FA0024294
FACILITY_NAME
STOCKTON TERMINAL TECHNICAL COMMITTEE (STTC)
STREET_NUMBER
3003
STREET_NAME
NAVY
STREET_TYPE
DR
City
STOCKTON
Zip
95206
APN
14503011
CURRENT_STATUS
Active, billable
QC Status
Approved
Scanner
SJGOV\gmartinez
Supplemental fields
Site Address
3003 NAVY DR STOCKTON 95206
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
230
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
MONITORING AND REPORTING ORDER NO. R5-2017-0826 -4- <br /> BUCKEYE PARTNERS, L.P.AND <br /> TESORO PETROLEUM COMPANY <br /> STOCKTON TERMINALS TECHNICAL COMMITTEE <br /> STOCKTON, SAN JOAQUIN COUNTY <br /> internet to the State Water Resources Control Board GeoTracker database system by <br /> 15 May (first semi-annual report) and 15 November (second semi-annual report), or <br /> as otherwise indicated by Central Valley Water Board staff, until such time as the <br /> Executive Officer determines that the reports are no longer necessary. Each report shall <br /> include the following minimum information: <br /> (a) A description and discussion of the groundwater sampling event and results, <br /> including trends in the concentrations of pollutants and groundwater elevations in the <br /> wells, how and when samples were collected, and'whether the pollutant plume(s) is <br /> delineated. <br /> (b) Field logs that contain, at a minimum, water quality parameters measured before, <br /> during, and after purging, method of purging, depth of water, volume of water <br /> purged, etc. <br /> (c) Groundwater contour maps for all groundwater zon a es, if pplicable. <br /> (d) Isocontour pollutant concentration maps for all groundwater zones and all major <br /> constituents of concern, if applicable. <br /> (e) A table showing well construction details such as well number, groundwater zone <br /> being monitored, coordinates (longitude and latitude), ground surface elevation, <br /> reference elevation, elevation of screen, elevation of bentonite, elevation of filter <br /> pack, and elevation of well bottom. <br /> (f) A table showing historical lateral and vertical (if applicable) flow directions and <br /> gradients. <br /> (g) Cumulative data tables for all major constituents of concern containing the water <br /> quality analytical results and depth to groundwater for all monitoring wells for the <br /> past five years, if applicable. The Central Valley Water Board may request <br /> additional data as necessary. <br /> (h) A copy of the laboratory analytical data report, which may be provided on electronic <br /> media and included in the report. <br /> (i) If applicable, the status of any ongoing remediation, including cumulative information <br /> on the mass of pollutant removed from the subsurface, system operating time, the <br /> effectiveness of the remediation system, and any field notes pertaining to the <br /> operation and maintenance of the system. <br /> (j) If applicable, the reasons for and duration of all interruptions in the operation of any <br /> remediation system, and actions planned or taken to correct and prevent <br /> interruptions. <br /> I <br /> 7. An Annual Report shall',be submitted to the Central Valley Water;Board by 15 November of <br /> each year. This report shall contain an evaluation of the effectiveness.and progress of the <br /> investigation and remediation, and may be substituted for;the second semi-annual <br /> monitoring report, provided that all information that must be submitted in the semi-annual <br /> report is included along with the following minimum information: <br />
The URL can be used to link to this page
Your browser does not support the video tag.