Laserfiche WebLink
Table 3-1 <br /> Summary of Proposed Sampling Locations and Rationale <br /> 3003 Navy Drive,Stockton,CA <br /> Location Proposed Proposed Proposed <br /> Application/Usage Type Upgradient/ Shallow Soil <br /> Location Name Description Description Downgradient Rationale/Proposed Action <br /> (based on 2021 Interviews) Background Samples <br /> Well Well (1-2 ft deep) <br /> U1 West Terminal Foam use area at Foam use at West Terminal truck loading rack.Contained TS-9R,SP-5 TS-1R Sample upgradient,downgradient,and cross-gradient <br /> Truck Rack on concrete;collected for offsite disposal. wells <br /> Sample upgradient,downgradient,and cross-gradient <br /> S1 West Terminal Foam storage area 1000-gallon foam storage tank located southwest of TS-9R,SP-5 TS-1R,TS-4R wells in proximity to and downgradient of the foam <br /> truck rack at West Terminal. storage tank.These sample locations create a perimeter <br /> around the known storage and release areas <br /> Collect one soil sample southeast of 600-gallon foam tank <br /> S2 East Annex Foam storage area 600-gallon foam tank at East Annex. 1 off the edge of the concrete pad(i.e.,below gravel <br /> covering soil). <br /> S3 East Annex Fire monitor with foam Two 55-gallon drums stored at East Annex for use with 1 Collect one soil sample off the south edge of the concrete <br /> fire monitor. pad for the two 55-gallon foam drums. <br /> Total Sampling Locations 2 2 2 <br /> Note:Although proposed wells TS-9R and SP-5 are listed as a downgradient wells with respect to Usage Area U1 and Storage Area S1,TS-911 and SP-5 will only be sampled once.Similarly,well TS-1R is listed as an <br /> upgradient well with respect to U1 and S1,however TS-111 will only be sampled once. <br />