SAN JOAQUIN Environmental Health Department <br /> COUNTY— <br /> Large Quantity Hazardous Waste Generator Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> LOVE'S TRAVEL STOP#538 115250 N THORNTON RD, LODI August 27, 2026 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I, CLASS II, or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 3 22 CCR 12 66262.17(a)(6), 66262.262 3010024-Contingency Plan, all revisions, and QRG maintained at the facility and <br /> submitted as required <br /> OBSERVATION: The Quick Reference Guide (QRG) has not been prepared and submitted to local police departments, <br /> fire departments, hospitals, State and local emergency response teams <br /> REGULATION GUIDANCE :Per California Code of Regulations Title 22 66262.262: A copy of the contingency plan and <br /> all revisions to the plan shall be maintained at the large quantity generator facility and: <br /> a. The large quantity generator shall submit a copy of the contingency plan and all revisions to all local emergency <br /> responders (i.e., police departments, fire departments, hospitals, and State and local emergency response teams that <br /> may be called upon to provide emergency services). <br /> (b)A large quantity generator that first becomes subject to these provisions after July 1, 2024, or a large quantity <br /> generator that is otherwise amending its contingency plan shall at that time submit a quick reference guide of the <br /> contingency plan to the local emergency responders identified at subsection (a)of this section or, as appropriate, the <br /> Local Emergency Planning Committee. <br /> CORRECTIVE ACTION: Create a QRG and submit it to the appropriate local emergency responders. In addition, submit <br /> a copy of the QRG to EHD and provide appropriate documentation showing it was given to the emergency responders. <br /> This is a (Minor)Violation. <br /> 4 22 CCR 12 66262.17(a)(6), 66262.261, 66262.263 3010023-Contingency plan contains all required content and reviewed <br /> and amended when required <br /> OBSERVATION: The Contingency Plan does not contain all required content <br /> -The Contingency Plan provided by Manager Jesse Diaz did not include the name, address and phone number of the <br /> Emergency Coordinator. Additionally, it does not include the phone number for CalOES. <br /> REGULATION GUIDANCE: Failure to include all of the following in the Contingency Plan: description of actions <br /> personnel will take in response to a release or emergency, arrangements with local authorities, list of emergency <br /> coordinators including name, addresses & phone numbers, list of emergency equipment and their physical description, <br /> location and capabilities, evacuation plan, and OES phone number. (If the owner or operator has already prepared a Spill <br /> Prevention, Control, and Countermeasures (SPCC) Plan or some other emergency or contingency plan, the owner or <br /> operator need only amend that plan to incorporate hazardous waste management provisions.) OR; Failure to review and <br /> immediately amend whenever: (1)Applicable regulations are revised; (2)The plan fails in an emergency; (3)The <br /> generator facility changes in its design, construction, operation, maintenance, or other circumstances in a way that <br /> materially increases the potential for fires, explosions, or releases of hazardous waste or hazardous waste constituents, <br /> or changes the response necessary in an emergency; (4)The list of emergency coordinators changes; or(5)The list of <br /> emergency equipment changes. <br /> CORRECTIVE ACTION: Revise the Contingency Plan to include all required content and submit a copy to the CUPA. <br /> This is a (Minor)Violation. <br /> EHD-CUPA Inspection Report IS03 Page 5 of 9 FA0021886 PRO539989 4692575 8/28/2026 <br /> a <br /> CP25-HW LQG g <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjgov.org/EHD <br />