My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2026
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
T
>
THORNTON
>
15250
>
2200 - Hazardous Waste Program
>
PR0539989
>
COMPLIANCE INFO_2026
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/30/2026 2:24:16 PM
Creation date
6/30/2026 7:58:06 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2200 - Hazardous Waste Program
File Section
COMPLIANCE INFO
FileName_PostFix
2026
RECORD_ID
PR0539989
PE
2228 - GEN 25<50 TONS PERMIT
FACILITY_ID
FA0021886
FACILITY_NAME
LOVE'S TRAVEL STOP #538
STREET_NUMBER
15250
Direction
N
STREET_NAME
THORNTON
STREET_TYPE
RD
City
LODI
Zip
95242
CURRENT_STATUS
Active, billable
QC Status
Approved
Scanner
SJGOV\kblackwell
Supplemental fields
Site Address
15250 N THORNTON RD Lodi 95242
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
225
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN JOAQUIN Environmental Health Department <br /> COUNTY— <br /> Large Quantity Hazardous Waste Generator Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> LOVE'S TRAVEL STOP#538 115250 N THORNTON RD, LODI Auqust 27, 2026 <br /> 31 22 CCR 12 66262.16(b)(4)(A), 66262.17(a)(5)(A) 3030007-Labeled all containers or portable tanks containing hazardous <br /> waste <br /> OBSERVATION: The following containers were observed without a complete hazardous waste label: <br /> - (2) 55-gallon black drums located on the blue pallet in the shop had approximately 4oz of used oil at the bottom of the <br /> drum and both containers did not have a label <br /> - (3) 55-gallon black drums located on the black pallet in the shop has hazardous waste but the label is missing the words <br /> "Hazardous Waste", name and address of the generator, physical state, the indication of the hazardous, and the <br /> composition of the wastes was incorrect. These drums contain a mixture of metal and paper filters. Additionally, these <br /> drums have a pool of used oil at the bottom about 4 inches high. <br /> REGULATION GUIDANCE: Per California Code of Regulations Title 22 66262.17, containers need to be labeled with the <br /> following information: <br /> (A) Containers. A large quantity generator shall mark or label its containers with the following: <br /> 1. The words "Hazardous Waste"; <br /> 2. The composition and physical state of the wastes; <br /> 3. An indication of the hazards of the contents [examples include, but are not limited to, the applicable hazardous waste <br /> characteristic(s) (i.e., ignitable, corrosive, reactive, toxic) <br /> 4. The name and address of the person generating the waste; <br /> 5. The date upon which each period of accumulation begins <br /> 6. The date the applicable accumulation period . <br /> CORRECTIVE ACTION: Provide a corrective action statement to the EHD once the containers are labeled. <br /> This is a (Minor)Violation. <br /> 34 22 CCR 12 66262.15(a)(4), 66262.17(a)(1)(D) 3030018-Containers of hazardous waste closed except when adding or <br /> removing waste <br /> OBSERVATION: The following containers were observed open without a lid <br /> - (2) 55-gallon black drums located on the blue pallet in the shop had approximately 4oz of used oil at the bottom of the <br /> drum <br /> - (3) 55-gallon black drums located on the black pallet in the shop has hazardous waste. These drums contain a mixture <br /> of metal and paper filters. Additionally, these drums have a pool of used oil at the bottom about 4 inches high. <br /> REGULATION GUIDANCE: Failure to meet the following container management requirements: <br /> (a)A container holding hazardous waste must always be closed during storage, except when it is necessary to add or <br /> remove waste. <br /> (b)A container holding hazardous waste must not be opened, handled, or stored in a manner which may rupture the <br /> container or cause it to leak. <br /> (c)A container holding hazardous waste in a satellite accumulation area must always be closed during storage, except <br /> when it is necessary to add or remove waste, or when temporary venting of a container is necessary for the proper <br /> operation of equipment or to prevent dangerous conditions such as build-up of extreme pressure. <br /> CORRECTIVE ACTION: Submit documentation to the CUPA demonstrating that the container listed above has been <br /> properly closed, and/or stored in a manner that will not cause the container to rupture or leak. <br /> This is a (Minor)Violation. <br /> EHD-CUPA Inspection Report IS03 Page 7 of 9 FA0021886 PRO539989 4692575 8/28/2026 <br /> a <br /> CP25-HW LQG g <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjgov.org/EHD <br />
The URL can be used to link to this page
Your browser does not support the video tag.