My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2026
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
COLEY
>
1812
>
2300 - Underground Storage Tank Program
>
PR0231881
>
COMPLIANCE INFO_2026
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/8/2026 9:14:49 AM
Creation date
7/8/2026 9:12:39 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2026
RECORD_ID
PR0231881
PE
2371 - UST FACILITY - 1702 COMPLIANT
FACILITY_ID
FA0003946
FACILITY_NAME
AT&T California - UG010
STREET_NUMBER
1812
STREET_NAME
COLEY
STREET_TYPE
AVE
City
Escalon
Zip
95320
APN
22715414
CURRENT_STATUS
Active, billable
QC Status
Approved
Scanner
SJGOV\bmascaro
Supplemental fields
Site Address
1812 Coley AVE Escalon 95320
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
38
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
T I T <br />pY�i f6 xyi K�a��t�M 701 N. Parknnlaf OrNe, Sana Ana, CA 42705 <br />p:714fFs6O/a222 www.Wt"m <br />Identification of Test Procedures for Secondary Containment Testing <br />To Whom It May Concern: <br />Tait Environmental Services, Inc., utilizes the following procedures when conducting Secondary <br />Containment Testine: <br />1) Containment Sumps, Transition Sumps, UDCs —Tait follows PEI-RP1200-17 Section 6.6 for the <br />accelerated test method. Tait uses the Incon TS -1000 hydrostatic test equipment following the <br />attached procedures. <br />2) Spill Buckets; Direct Bury & Contained in Sumps —Spill buckets contained in sumps are tested <br />per PEI -1200-17, Section 6.2, however Tait Pass/Fail threshold is 0" drop in one hour. Direct Bury <br />Spill Buckets are test the same as containment sumps per PEI -1200-17, Section 6.6. <br />3) Tank Annular Space — testing is conducted per PEI -1200-17, Section 4.2 <br />4) Piping Secondary Containment —Testing is conducted per PEI-RP1200-17, Section 5.3 <br />Please consider this letter as our Test Procedure utilized when conducting Secondary Containment <br />Testing in lieu of either parts or the whole RP1200 document due to copyright infringement. <br />
The URL can be used to link to this page
Your browser does not support the video tag.