My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2026
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
COLEY
>
1812
>
2300 - Underground Storage Tank Program
>
PR0231881
>
COMPLIANCE INFO_2026
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/8/2026 9:14:49 AM
Creation date
7/8/2026 9:12:39 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2026
RECORD_ID
PR0231881
PE
2371 - UST FACILITY - 1702 COMPLIANT
FACILITY_ID
FA0003946
FACILITY_NAME
AT&T California - UG010
STREET_NUMBER
1812
STREET_NAME
COLEY
STREET_TYPE
AVE
City
Escalon
Zip
95320
APN
22715414
CURRENT_STATUS
Active, billable
QC Status
Approved
Scanner
SJGOV\bmascaro
Supplemental fields
Site Address
1812 Coley AVE Escalon 95320
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
38
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Underground Storage Tank <br />Release Detection Equipment Testing Report Form <br />7. LINE LEAK DETECTOR TEST RESULTS <br />9 Check this box if line leak detectors ARE NOT installed. (Do not complete this section.) <br />❑ Check this box if Appendix 5.2 continuation page is attached. <br />Simulated release rate verified: (Check all that apply.) <br />❑ 3 GPH ❑ 0.1 GPH (Required only if LLD performs line tightness testing) <br />Yes <br />No <br />NA <br />Has the testing equipment been properly calibrated? <br />❑ <br />❑ <br />❑ <br />For emergency tank systems, does the LLD create an audible and visual alarm <br />when a release is detected? <br />El <br />1:1 <br />❑ <br />For mechanical LLDs, does the LLD restrict the flow through the pipe when a <br />release is detected? <br />El <br />1:1 <br />❑ <br />For electronic LLDs, does the pressure supply pump automatically shut off when <br />a release is detected? <br />❑ <br />❑ <br />❑ <br />For electronic LLDs, does the pressure supply pump automatically shut off if the <br />monitoring system or LLD is disabled or disconnected? <br />❑ <br />❑ <br />❑ <br />For electronic LLDs, does the pressure supply pump automatically shut off if the <br />monitoring system or LLD malfunctions or fails a tightness test? <br />❑ <br />❑ <br />❑ <br />For electronic LLDs, have all accessible wiring connections been visually <br />inspected for kinks and breaks? <br />❑ <br />❑ <br />❑ <br />Were all items on the equipment manufacturer's maintenance checklist <br />completed? <br />❑ <br />❑ <br />❑ <br />Were all LLDs confirmed operational within regulatory requirements? <br />❑ <br />❑ <br />❑ <br />List only line leak detectors tested. <br />LLD ID <br />LLD Model <br />Lines Monitored <br />Pass <br />Fail <br />❑ <br />❑ <br />❑ <br />0 <br />- <br />IT <br />❑ <br />EL <br />❑ <br />❑ <br />❑ <br />❑ <br />❑ <br />EL <br />❑ <br />Describe all answers marked "No" or "Fail" and the proposed remedy in Section 8. <br />List all equipment either replaced or repaired (including cleaning or adjustment) in Section 8. <br />Page 4 of 6 <br />
The URL can be used to link to this page
Your browser does not support the video tag.