Laserfiche WebLink
Project Scope and Gen. In VICINITY MAP <br /> SCOPE :ADDTION OF BATHROOM 73 SF TO REAR OF HOME 1kPl <br /> THIS PROJECT SHALL CONFORM TO THE 2025 CRC, CEC, CPC, t <br /> CMC,CEnC, CFC,and CITY OF STOCKTON Municipal Code. r •-0 ' <br /> Occupancy: R3 10 .* <br /> Type of Construction:VBorwl <br /> - ay <br /> Number of Stories: 1 • <br /> Fire Sprinklers: NO <br /> Zoning: RL-Low Density Residential y <br /> R a 16 �. <br /> ta <br /> ■ <br /> + gePoint <br /> Fsheet Index •� - <br /> .• <br /> A-0-SITE PLAN&NOTES <br /> ft A-1-FLOOR PLAN, MEP PLAN, FOUNDATION PLAN/BWP PLAN o <br /> A-2-DETAILS Owl a 2122iWLSwain Rd, <br /> A-3-ELEVATIONS CON <br /> A-4 TITLE 24 ALD�. + ' <br /> Q�pFESSIDA� <br /> Amw � I0 S E '���► <br /> General Speifications IFS y� <br /> s <br /> 1.CONTRACTOR SHALL VERIFY ALL DIMENSIONS,ELEVATIONS,AND , <br /> CONDITIONS OF THE SITE AND EXISTING CONDITIONS PRIOR TO 5C " W 9=1 R� <br /> COMMENCING CONSTRUCTION. IF THERE ARE ANY DISCREPANCIES ' `T t• J <br /> BETWEEN THE EXISTING CONDITIONS AND THE DRAWINGS AND '" • �' 1 <br /> SPECIFICATIONS,THE CONTRACTOR SHALL NOTIFY THE OWNER 92'-114" <br /> IMMEDIATELY IN WRITING. IN NO CASE SHALL DIMENSIONS BE SCALED No. C 88326 <br /> FROM PLANS,SECTIONS,OR DETAILS ON THE DRAWINGS OR <br /> CALCULATIONS. �N R� �,�� C� {�'� OA <br /> 2.ALL OMISSIONS AND CONFLICTS BETWEEN THE VARIOUS ELEMENTS Y <br /> OF THE WORKING DRAWINGS AND OR SPECIFICATIONS SHALL BE ��� ° F OF G <br /> BROUGHT TO THE ATTENTION OF THE ENGINEER OR THE DESIGNER a ° °° ° 5 <br /> BEFORE PROCEEDING WITH ANY WORK SO INVOLVED. ° ° ° a ° <br /> 3.THE CONTRACTOR SHALL LOCATE AND PROTECT ALL EXISTING ° a ° ° ° ° ° ° ° <br /> UTILITY LINES AND CONNECTIONS INCLUDING SEWER,WATER,GAS, ° ° ° <br /> a °° <br /> AND ELECTRIC SERVICES BEFORE AND DURING HIS WORK. ° ° ° ° 44 ° ° °° °d °° <br /> 4.WHERE A CONSTRUCTION DETAIL IS NOT SHOWN OR NOTED,THE ° ° a 44, ° <br /> DETAIL SHALL BE THE SAME AS FOR OTHER SIMILAR WORK. ° ° ° ° ° ° a ° ° a a ° °� ° — <br /> 5. NO PIPES, DUCTS,SLEEVES,CHASES, ETC.,SHALL BE PLACED IN DESIGNER INFO ° ° d° ° ° 4,d °- <br /> SLABS, FOOTING, BEAMS,OR WALLS UNLESS SPECIFICALLY SHOWN OR ° ° ° 44 ° PROPERTY LINE <br /> ° <br /> NOTED, NOR SHALL ANY STRUCTURAL MEMBER BE CUT FOR PIPES, ° ° <br /> DUCTS, ETC., UNLESS OTHERWISE NOTED.CONTRACTOR SHALL ° d° ° ° ---- <br /> OBTAIN PRIOR APPROVAL FOR INSTALLATION OF ANY ADDITIONAL PHIL RAINONE ° <br /> PIPES, DUCTS, ETC. RIPON DESIGNS ° ° 15'-02" <br /> NORTH <br /> 6.CONTRACTOR AGREES THAT HE SHALL ASSUME SOLE AND 12349 W. RIPON ROAD <br /> COMPLETE RESPONSIBILITY FOR JOB SITE CONDITIONS DURING THE RIPON, CA ° ° <br /> COURSE OF CONSTRUCTION OF THIS PROJECT, INCLUDING SAFETY OF 209-923-3776 ° <br /> ALL PERSONS AND PROPERTY;THAT THIS REQUIREMENT SHALL APPLY 22'-32" PROJECT NAME <br /> CONTINUOUSLY AND NOT BE LIMITED TO NORMAL WORKING HOURS; ° a ° 15' <br /> AND THAT THE CONTRACTOR SHALL DEFEND, INDEMNIFY AND DALMAN <br /> HOLD THE OWNER AND THE ENGINEER HARMLESS FROM ANY AND ALL <br /> DEFERRED ITEMS <br /> LIABILITY, REAL OR ALLEGED, IN CONNECTION WITH THE PERFORMANCE ° RESIDENCE <br /> OF WORK ON THIS PROJECT, EXPECTING FOR LIABILITY ARISING FROM ° ° <br /> THE SOLE NEGLIGENCE OF THE OWNER OR THE ° <br /> ENGINEER. ) ° 31'-2" <br /> 7.CONTRACTOR SHALL TAKE PRECAUTIONARY MEASURES TO ENSURE ° 26' 19, <br /> THAT ALL PROPERTY IS PROTECTED DURING THIS OPERATION.ANY ° ° 15' SETBACK EXCEPTION <br /> —T <br /> DAMAGES OR CHANGED CONDITIONS SHALL BE REPAIRED AND ALLOWED PER COUNTY - <br /> RESTORED TO A CONDITION EQUAL TO THAT EXISTING AT THE ° PROJECT ADDRESS <br /> COMMENCEMENT OF THE WORK.CONTRACTOR SHALL RESTORE ANY PLANNING <br /> DAMAGE AT HIS OWN EXPENSE. <br /> 8.THE DESIGN,ADEQUACY AND SAFETY OF ERECTION BRACING, a 20 <br /> SHORING,TEMPORARY SUPPORTS, ETC., IS THE RESPONSIBILITY OF 212 2 SWAIN R D <br /> THE CONTRACTOR,AND HAS NOT BEEN CONSIDERED BY THE DESIGN ° PROPOSED <br /> ENGINEER,THE DESIGNER,THE CONTRACTOR I S RESPONSIBLE °° ° STOCKTON CA <br /> FOR THE STABILITY OF THE STRUCTURE PRIOR TO THE APPLICATION OF ° ADU <br /> ALL SHEAR WALLS. ° <br /> ° ° <br /> ° <br /> DRAWING NAME <br /> Fire and Life Safet Notes ° <br /> ° <br /> HABITABLE ROOMS SHALL HAVE AN AGGREGATE GLAZING AREA OF NOT m ° <br /> LESS THAN 8% OF THE FLOOR AREA. NATURAL VENTILATION SHALL BE ° <br /> THROUGH WINDOWS, SKYLIGHTS, DOORS, LOUVERS OR OTHER APPROVED SITE PLAN AND NOTES <br /> OPENINGS TO THE OUTSIDE AIR. THE OPENABLE AREA TO THE OUTDOORS ° 4'ADU <br /> SHALL BE NOT LESS THAN 4%OF THE FLOOR AREA VENTILATED. <br /> d <br /> REQUIREMENTS FOR EMERGENCY ESCAPE AND RESCUE OPENINGS: <br /> • BOTTOM OF THE CLEAR OPENING NOT GREATER THAN 44 INCHES ABOVE ° 104'-84" <br /> SUBMITTAL DATE <br /> THE FLOOR a° <br /> • MINIMUM NET CLEAR OPENING OF 5.7 SQUARE FEET (5 SQUARE FEET ° <br /> PERMITTED FOR GRADE FLOOR OPENINGS) PLAN CHECK 4-18-24 <br /> • MINIMUM NET CLEAR OPENING HEIGHT OF 24 INCHES ° LLI <br /> • MINIMUM NET CLEAR OPENING WIDTH OF 20 INCHES ° Z EXSITING SFD <br /> • OPERATIONAL FROM INSIDE OF THE ROOM WITHOUT THE USE OF KEYS, ° ° J U.1 <br /> TOOLS,OR SPECIAL KNOWLEDGE <br /> J <br /> SMOKE ALARMS SHALL RECEIVE THEIR PRIMARY POWER FROM THE ° >- <br /> BUILDING WIRING WITH BATTERY BACK UP AND BE INTERCONNECTED IN ° a ° a 7- <br /> SUCH A MANNER THAT THE ACTIVATION OF ONE ALARM WILL ACTIVATE J ° O W <br /> ALL THE ALARMS. 0- ° (Y- 0- <br /> CARBON MONOXIDE ALARMS SHALL RECEIVE THEIR PRIMARY Q ° n O <br /> POWER FROM THE BUILDING WIRING WITH BATTERY BACK UP AND BE a a <br /> INTERCONNECTED IN SUCH A MANNER THAT THE ACTIVATION OF ONE LL <br /> ALARM WILL ACTIVATE ALL THE ALARMS. [CRC§R315.5&§R315.7] 73'_34' z °° O <br /> ALL WOOD SLEEPERS ARE PROTECTED FROM DECAY BY THE USE ° ° o <br /> OF NATURALLY DURABLE WOOD OR PRESSURE-TREATED �/ DATE REVISION <br /> WOOD. /� o <br /> LU ° ° <br /> J ` <br /> Q O <br /> Energy Notes ° <br /> ° <br /> ° <br /> ALL INSTALLED LUMINAIRES SHALL BE HIGH EFFICACY IN <br /> ACCORDANCE WITH CENC TABLE 150.0-A.[CENC§150.0(K)1A] <br /> ° <br /> ° <br /> IN BATHROOMS,GARAGES, LAUNDRY ROOMS AND UTILITY ROOMS, <br /> AT LEAST ONE LUMINAIRE IN EACH OF THESE SPACES SHALL BE a° DRIVEWAY <br /> CONTROLLED BY A VACANCY SENSOR.[CENC§150.0(K)2J] ° ° <br /> LIGHTING REQUIRED TO COMPLY REFERENCE JOINT APPENDIX JA8 <br /> PER CENC TABLE 150.0-A SHALL BE CONTROLLED BY DIMMERS OR a <br /> VACANCY SENSORS.[CENC§150.0(K)2K] <br /> ° <br /> UNDERCABINET LIGHTING SHALL BE SWITCHED SEPARATELY ° <br /> DRAWN BY:GN CHECKED BYGN <br /> FROM OTHER LIGHTING SYSTEMS.[CENC§150.0(K)2L] <br /> a <br /> ° ° <br /> ° <br /> 4-18-24 SCALE: SEE PLAN <br /> G ° <br /> d <br /> ° <br /> THERE IS 14' RIVER ° PROJECT NUMBER: 23008 <br /> SLOUGH TO THE PROPERTY LINE DRAWING NUMBER: <br /> SOUTHWEST OF <br /> PROPOERTY SITE PLAN 113'-34" <br /> 1 SCALE: 1/8" = 1'-0" <br /> A- 0 <br />