Laserfiche WebLink
24. Light bulbs and tubes shall be enclosed in plastic safety shield or equivalent. (114323 (c) <br />26. Obtain a verification of commissary. <br />Any item(s) inadvertently overlooked in the plan check process, which is not in compliance with applicable <br />State laws, and/or city or county ordinance codes, shall be constructed or reconstructed upon request of <br />the EHD. Inferior workmanship, equipment, or materials will not be accepted for the construction or <br />operation of a food facility. Any variance from the requirements outlined in this letter will require written <br />approval from the EHD. Approval of the submitted plans shall become null and void if the work authorized <br />is not commenced within 180 days from the date of approval, or the work authorized by such plans is <br />abandoned. In order to renew action on an expired plan approval, the applicant shall submit fees equal <br />25. The passthrough windows shall be limited to 216 square inches, limited to 432 square inches if <br />equipped with air curtain, shall be no closer than 18 inches from each other, have openings <br />equipped with self-closing solid windows or screens and the screens shall be at least 16 mesh/ <br />inch. (114259.2) <br />22. The exhaust hood must be constructed to meet the requirements of the California Mechanical <br />Code. (114149.1) <br />23. Provide a 10 BC-rated fire extinguisher. (114323) (c) <br />The EHD must be kept informed of the construction progress. A final inspection must be performed, <br />operating permit fees paid, and approval to operate granted prior to opening for business. All equipment <br />must be installed and thorough cleaning completed prior to the final inspection. Inspections must be <br />scheduled at least 48 hours in advance. Charges for additional inspections, re-inspections and/or <br />consultations may be assessed at the EHD hourly rate of $172 per hour. <br />13. The 3-comp warewash sink shall have a swivel faucet capable of serving all compartments. <br />(114313 (c) <br />14. Coffee urns, deep fat fryers, steam tables, and similar equipment shall have positive closing lids <br />with secure latch mechanism that will prevent excessive spillage. (114323 (b) <br />15. Floors, walls, and ceilings of all enclosed food preparation areas shall have impervious, smooth, <br />and easily cleanable surfaces. (114301 (g) <br />16. Floor and wall junction shall be coved with 3/8" minimum radius coving, and floor surface <br />extends up at least 4 inches (114301 (g) <br />17. Floor mounted equipment shall be sealed to the floor or be at least 6" off the floor on easily <br />cleanable legs and feet. (114301 (g) <br />18. Equipment shall be sealed together, or spaced a minimum of 4" apart from each other. (114301 <br />(g) <br />19. Equipment joints and seams shall be tightly fitted and sealed; silicone sealant or waterproof <br />compounds if gap is smaller than % inch. (114301 (b) <br />20. There should be no exposed threads, nuts, or rivets that interfere with proper cleaning. (114301 <br />(g) <br />21. Gas-fired appliances shall be insulated to prevent excessive heat buildup and injury. (114323 (g)