Laserfiche WebLink
iSNavieN <br />THE LEADER IN CONDENSING TECHNOLOGY NPE-2 Series Tankless Water Heaters <br />Specification Sheet <br />NPE-180A2 |NPE-ia0S2 NPE-210 A2 |NPE-210S2 NPE-24OA2 |nPE-240S2 <br />13,300-199,900 BTU/H10,000-150,000 BTU/H 12.000-180.000BTU/H <br />UEFWxNGim 0.95 0.96 0.95 0.96 0.95 0.960.93 <br />8.4 GPM (32 Um)10.1 GPM(38L/m)112 GPM (42 Um) <br />6.5 GPM (25 Um)7.8 GPM (30 Um)8.7 GPM (33 Um) <br />Dimensions <br />Weight <br />Overhead View <br />3.5inWC-10.5in WC <br />8inWC-13inWC <br />-0.03 in WC--0.55 in WC -0.03 in WC --0.76 in WC -0.03 in WC--0.96 in WC <br />-0.02 in WC--0.55 inWC -0.02 inWC--O.76inWC -0.02 in WC --0.96 in WC <br />Supply Connections <br />® ©9Diameter <br />VJnNPT2 In <br />F4u jit Gat Vent 2in & <br />0 <br />Power Supply 200 W (max 2 A), 3 50 W (max 4 A) with external pump connected <br />o Cold W.U. Inlet <br />U"a-riWn~„« U»<7 Jrwt <br />Materials <br />| NPE-180A2 /210A2 / 240a7| <br />Exhaust <br />Supply Connection!Venting Intake©©Diameter <br />Vent Clearances2 in <br />EthouU Got Vent Jin High Elevation 10,100 feet for both NG or LP gas. Please refer to Installation Manual for additional details and instructions <br />Hol Wo let Outlet ■/.In <br />0 Got Inlet Safety Devices <br />Couden Mie Outlet <br />Cold water Inlet <br />I J" JBwM <br />t?lt-i*c-n <br />| NPE-150S2 /180S2 / 210S2 / 240S2 | <br />* Navien reserves the right to change specifications at any time without prior notice <br />Navien, Inc. 20 Goodyear, Irvine, CA 92618 Ph: (949)420-0420 Fax: (949)420-0430 www.Navienlnc.com 1-NPE2-SS-00I-1.1 <br />iamyWj <br />I <br />I s <br />Premium Condensing <br />Tankless Gas Water Heater <br />• NPE-150S2 model not certified by EnergyStar <br />'• Available for ‘A2'models configured in an optional ComfortFlow recirculation mode. Energy consumption will Increase when the system is <br />configured for recirculation. <br />Flame Rod, APS. Ignition Operation Detector. Water Temperature High limit Switch, Exhaust Temperature High Limit Sensor, <br />Power Surge Fuse, Burner High Limit Fuse, Vent Installation Detector (VID) <br />Natural Gas. <br />Propane Gas <br />4.3 GPM <br />(16 Um) <br />73 lbs <br />(33 kg) <br />4.4 GPM <br />(17 Um) <br />68 lbs <br />(31 kg) <br />5.1 GPM <br />(19 Um) <br />77 lbs <br />(35 kg) <br />S3 GPM <br />(20 Um) <br />73 lbs <br />(33 kg) <br />5.6 GPM <br />(21 Um) <br />77 lbs <br />(35 kg) <br />5.8 GPM <br />(22 Um) <br />73 lbs <br />(33 kg) <br />Flow Rate <br />(DHW) <br />Connection <br />Sizes <br />i f <br />a <br />ta IT <br />I <br />(ias precl, tankless, condensing, wall mounted water heater(s) shall be direct vent NPE-2 Series models as manufactured by Navien, Inc. and are certified by CSA Group to the latest edition of <br />ANSI Standard Z21.10.3-CSA 4.3. Water heater(s) shall have a 15(5)-year limited Heal Exchanger warranty and 5(3)-year limited Parts warranty (8(5)-year Heat Exchanger and 5(3)-year <br />Parts for Commercial use) per Navien Limited Warranty. Unit(s) shall be designed to burn natural gas and can be for use with propane when a Gas Conversion Kit is installed._____(qty)- <br />NPE water he.ater(s) shall have a nominal flow rate capacity of______GPM/GPH at______"Prise with rated input of BTU/hr. Water heater(s) shall be vented with 2" Schedule <br />40/80 PVC/CPVC, approved polypropylene and stainless steel vent pipe at a distance not to exceed 75' (or equivalent) with each elbow equal to 8' of pipe length or 3“ Schedule 40/80 PVC/ <br />CPVC, approved polypropylene and stainless steel vent pipe at a distance of 150' (or equivalent) with each elbow equal to 5'of pipe length. Water heater(s) is rated for 150 PSI working water <br />pressure and 300 PSI test pressure. Gas supply pressure shall be 3.5" to 10.5" WCfor natural gas and 8.0" to 13.0" WC for propane. Unit(s) shall have a steel case, dual stainless steel heat <br />exchangers, eco premixed burner, negative pressure gas valve, dual venturi, 3/4" inlet gas connection, 3/4" brass inlet/outlet water connections, water holding capacity of 0.6 gallons for the <br />NPE-150S2,1.0 gallon for the NPE-180A2 model (0.7 gallons for NPE-180S2 model), 1.2 gallons for the NPE-210A2/NPE-240A2 models (0.7 and 0.9 gallons for NPE-21052 and NPE-240S2 <br />models respectively), and a condensate collector. The NPE-180A2 model weighs 73 lbs (NPE-18052 weighs 68 lbs), and the NPE-210A2/NPE-240A2 models weigh 77 lbs (NPE-210S2 and <br />NPE-240S2 weigh 73 lbs) and the NPE-15052 weigh 62lbs. Unit(s) shall include features such as an adjustment for installations at high elevation, temperature lockout, and temperature <br />options from 97-120°Fin 1°F intervals and 120-140°Fin rFintervals. The unit(s) shall include additional temperature options of 140-185°F in rFintervals. for high temperature commercial <br />applications. All NPE "A2" models shall include an internal circulation pump and 0.5-gallon buffer tank. The water heater(s) shall he controlled by an internal circuit board that monitors the <br />inlet and outlet temperatures with installed thermistors, sensing and controlling flow rate to set point temperature with air-fuel ratio controls in order to maintain thermal combustion <br />efficiency, l)nit(s) shall include safety features such as fame sensor system, high limit sensors, overheat prevention device, freeze, protection mode, and fan motor rotation detector. Multi­ <br />system (cascade) applications that require 2 to 32 units shall be installed by connecting the units using cable only connections (Ready Link). The water heater(s) exceeds the energy efficiency <br />requirements ofASIIRAE 90.1-2010 and is listed by SCAQMD Rule 1146.2 (Type 1) as compliant with Rule 1146.2 (Type 1) for Ultra Low NOx requirements of 14 ng/J or 20 ppm @ 3% 02. <br />Oeurtpton <br />Air Intake <br />Zin <br />Win <br />NPE-150S2* <br />18,000-120,000 <br />BTU/H <br />Hot Weter Outlet <br />Gu Inlet <br />RecHtUetlon Inlet <br />CondenMle Outlet <br />Oewrtpkon <br />Air Intkke <br />7. in <br />7. In <br />7. In <br />7. in <br />•/»m <br />‘/.In <br />Item <br />Heat Capacity <br />(Input) <br />Uniform <br />Energy Factor <br />SS'FdO’C) <br />Temp Rise <br />45 "F (25‘Cl <br />Temp Rise <br />67’F (36'0 <br />Temp Rise <br />Hot Water <br />Outlet <br />Gas Inlet <br />Mam Supply <br />Maximum <br />Power <br />Consumption <br />Casing <br />Heat <br />Exchangers <br />6.8 GPM <br />(25.8 Um) <br />53 GPM <br />(20 Um) <br />3.4 GPM <br />(13 Um) <br />173 in (W) x 27.4 in (H) x 13.2 in (D) <br />62 lbs <br />(28 kg) <br />Indoor or Outdoor Wall-Hung <br />Forced Draft Direct Vent <br />Electronic Ignition <br />15-150 PSI <br />-0.04 in WC- <br />-0.40 in WC <br />-0.03 in WC- <br />-0.40 in WC <br />0.5 GPM (1.9 Um), < 0.01 GPM (0.04 Um) option for-A2"models" <br />VeinNPT <br />VeinNPT <br />120VAC60HZ <br />Cold Rolled Carbon Steel <br />Primary Heat Exchanger: Stainless Steel <br />Secondary Heat Exchanger Stainless Steel <br />2 In or 3 in PVC, CPVC. Approved Polypropylene and stainless steel <br />2 in or 3 in Special Gas Vent Type BH (Class II, A/B/C) <br />2 in or 3 in PVC, CPVC. Approved Polypropylene and stainless steel <br />2 in or 3 in Special Gas Vent Type BH (Class II, A/B/C) <br />0 in to combustibles <br />Installation Type <br />Venting Type <br />Ignition_________________ <br />Water Pressure <br />Natural Gas Supply Pressure <br />(from source)_____________ <br />Propane Gas Supply Pressure <br />(from source) <br />Natural Gas Manifold Pressure <br />(min-max)_______________ <br />Propane Gas Manifold Pressure <br />(min-max) <br />Minimum Flow Rate <br />Cold Water Inlet <br />at <br />□LI <br />/ <br />4V <br />Front View <br />I!