iSNavieN
<br />THE LEADER IN CONDENSING TECHNOLOGY NPE-2 Series Tankless Water Heaters
<br />Specification Sheet
<br />NPE-180A2 |NPE-ia0S2 NPE-210 A2 |NPE-210S2 NPE-24OA2 |nPE-240S2
<br />13,300-199,900 BTU/H10,000-150,000 BTU/H 12.000-180.000BTU/H
<br />UEFWxNGim 0.95 0.96 0.95 0.96 0.95 0.960.93
<br />8.4 GPM (32 Um)10.1 GPM(38L/m)112 GPM (42 Um)
<br />6.5 GPM (25 Um)7.8 GPM (30 Um)8.7 GPM (33 Um)
<br />Dimensions
<br />Weight
<br />Overhead View
<br />3.5inWC-10.5in WC
<br />8inWC-13inWC
<br />-0.03 in WC--0.55 in WC -0.03 in WC --0.76 in WC -0.03 in WC--0.96 in WC
<br />-0.02 in WC--0.55 inWC -0.02 inWC--O.76inWC -0.02 in WC --0.96 in WC
<br />Supply Connections
<br />® ©9Diameter
<br />VJnNPT2 In
<br />F4u jit Gat Vent 2in &
<br />0
<br />Power Supply 200 W (max 2 A), 3 50 W (max 4 A) with external pump connected
<br />o Cold W.U. Inlet
<br />U"a-riWn~„« U»<7 Jrwt
<br />Materials
<br />| NPE-180A2 /210A2 / 240a7|
<br />Exhaust
<br />Supply Connection!Venting Intake©©Diameter
<br />Vent Clearances2 in
<br />EthouU Got Vent Jin High Elevation 10,100 feet for both NG or LP gas. Please refer to Installation Manual for additional details and instructions
<br />Hol Wo let Outlet ■/.In
<br />0 Got Inlet Safety Devices
<br />Couden Mie Outlet
<br />Cold water Inlet
<br />I J" JBwM
<br />t?lt-i*c-n
<br />| NPE-150S2 /180S2 / 210S2 / 240S2 |
<br />* Navien reserves the right to change specifications at any time without prior notice
<br />Navien, Inc. 20 Goodyear, Irvine, CA 92618 Ph: (949)420-0420 Fax: (949)420-0430 www.Navienlnc.com 1-NPE2-SS-00I-1.1
<br />iamyWj
<br />I
<br />I s
<br />Premium Condensing
<br />Tankless Gas Water Heater
<br />• NPE-150S2 model not certified by EnergyStar
<br />'• Available for ‘A2'models configured in an optional ComfortFlow recirculation mode. Energy consumption will Increase when the system is
<br />configured for recirculation.
<br />Flame Rod, APS. Ignition Operation Detector. Water Temperature High limit Switch, Exhaust Temperature High Limit Sensor,
<br />Power Surge Fuse, Burner High Limit Fuse, Vent Installation Detector (VID)
<br />Natural Gas.
<br />Propane Gas
<br />4.3 GPM
<br />(16 Um)
<br />73 lbs
<br />(33 kg)
<br />4.4 GPM
<br />(17 Um)
<br />68 lbs
<br />(31 kg)
<br />5.1 GPM
<br />(19 Um)
<br />77 lbs
<br />(35 kg)
<br />S3 GPM
<br />(20 Um)
<br />73 lbs
<br />(33 kg)
<br />5.6 GPM
<br />(21 Um)
<br />77 lbs
<br />(35 kg)
<br />5.8 GPM
<br />(22 Um)
<br />73 lbs
<br />(33 kg)
<br />Flow Rate
<br />(DHW)
<br />Connection
<br />Sizes
<br />i f
<br />a
<br />ta IT
<br />I
<br />(ias precl, tankless, condensing, wall mounted water heater(s) shall be direct vent NPE-2 Series models as manufactured by Navien, Inc. and are certified by CSA Group to the latest edition of
<br />ANSI Standard Z21.10.3-CSA 4.3. Water heater(s) shall have a 15(5)-year limited Heal Exchanger warranty and 5(3)-year limited Parts warranty (8(5)-year Heat Exchanger and 5(3)-year
<br />Parts for Commercial use) per Navien Limited Warranty. Unit(s) shall be designed to burn natural gas and can be for use with propane when a Gas Conversion Kit is installed._____(qty)-
<br />NPE water he.ater(s) shall have a nominal flow rate capacity of______GPM/GPH at______"Prise with rated input of BTU/hr. Water heater(s) shall be vented with 2" Schedule
<br />40/80 PVC/CPVC, approved polypropylene and stainless steel vent pipe at a distance not to exceed 75' (or equivalent) with each elbow equal to 8' of pipe length or 3“ Schedule 40/80 PVC/
<br />CPVC, approved polypropylene and stainless steel vent pipe at a distance of 150' (or equivalent) with each elbow equal to 5'of pipe length. Water heater(s) is rated for 150 PSI working water
<br />pressure and 300 PSI test pressure. Gas supply pressure shall be 3.5" to 10.5" WCfor natural gas and 8.0" to 13.0" WC for propane. Unit(s) shall have a steel case, dual stainless steel heat
<br />exchangers, eco premixed burner, negative pressure gas valve, dual venturi, 3/4" inlet gas connection, 3/4" brass inlet/outlet water connections, water holding capacity of 0.6 gallons for the
<br />NPE-150S2,1.0 gallon for the NPE-180A2 model (0.7 gallons for NPE-180S2 model), 1.2 gallons for the NPE-210A2/NPE-240A2 models (0.7 and 0.9 gallons for NPE-21052 and NPE-240S2
<br />models respectively), and a condensate collector. The NPE-180A2 model weighs 73 lbs (NPE-18052 weighs 68 lbs), and the NPE-210A2/NPE-240A2 models weigh 77 lbs (NPE-210S2 and
<br />NPE-240S2 weigh 73 lbs) and the NPE-15052 weigh 62lbs. Unit(s) shall include features such as an adjustment for installations at high elevation, temperature lockout, and temperature
<br />options from 97-120°Fin 1°F intervals and 120-140°Fin rFintervals. The unit(s) shall include additional temperature options of 140-185°F in rFintervals. for high temperature commercial
<br />applications. All NPE "A2" models shall include an internal circulation pump and 0.5-gallon buffer tank. The water heater(s) shall he controlled by an internal circuit board that monitors the
<br />inlet and outlet temperatures with installed thermistors, sensing and controlling flow rate to set point temperature with air-fuel ratio controls in order to maintain thermal combustion
<br />efficiency, l)nit(s) shall include safety features such as fame sensor system, high limit sensors, overheat prevention device, freeze, protection mode, and fan motor rotation detector. Multi
<br />system (cascade) applications that require 2 to 32 units shall be installed by connecting the units using cable only connections (Ready Link). The water heater(s) exceeds the energy efficiency
<br />requirements ofASIIRAE 90.1-2010 and is listed by SCAQMD Rule 1146.2 (Type 1) as compliant with Rule 1146.2 (Type 1) for Ultra Low NOx requirements of 14 ng/J or 20 ppm @ 3% 02.
<br />Oeurtpton
<br />Air Intake
<br />Zin
<br />Win
<br />NPE-150S2*
<br />18,000-120,000
<br />BTU/H
<br />Hot Weter Outlet
<br />Gu Inlet
<br />RecHtUetlon Inlet
<br />CondenMle Outlet
<br />Oewrtpkon
<br />Air Intkke
<br />7. in
<br />7. In
<br />7. In
<br />7. in
<br />•/»m
<br />‘/.In
<br />Item
<br />Heat Capacity
<br />(Input)
<br />Uniform
<br />Energy Factor
<br />SS'FdO’C)
<br />Temp Rise
<br />45 "F (25‘Cl
<br />Temp Rise
<br />67’F (36'0
<br />Temp Rise
<br />Hot Water
<br />Outlet
<br />Gas Inlet
<br />Mam Supply
<br />Maximum
<br />Power
<br />Consumption
<br />Casing
<br />Heat
<br />Exchangers
<br />6.8 GPM
<br />(25.8 Um)
<br />53 GPM
<br />(20 Um)
<br />3.4 GPM
<br />(13 Um)
<br />173 in (W) x 27.4 in (H) x 13.2 in (D)
<br />62 lbs
<br />(28 kg)
<br />Indoor or Outdoor Wall-Hung
<br />Forced Draft Direct Vent
<br />Electronic Ignition
<br />15-150 PSI
<br />-0.04 in WC-
<br />-0.40 in WC
<br />-0.03 in WC-
<br />-0.40 in WC
<br />0.5 GPM (1.9 Um), < 0.01 GPM (0.04 Um) option for-A2"models"
<br />VeinNPT
<br />VeinNPT
<br />120VAC60HZ
<br />Cold Rolled Carbon Steel
<br />Primary Heat Exchanger: Stainless Steel
<br />Secondary Heat Exchanger Stainless Steel
<br />2 In or 3 in PVC, CPVC. Approved Polypropylene and stainless steel
<br />2 in or 3 in Special Gas Vent Type BH (Class II, A/B/C)
<br />2 in or 3 in PVC, CPVC. Approved Polypropylene and stainless steel
<br />2 in or 3 in Special Gas Vent Type BH (Class II, A/B/C)
<br />0 in to combustibles
<br />Installation Type
<br />Venting Type
<br />Ignition_________________
<br />Water Pressure
<br />Natural Gas Supply Pressure
<br />(from source)_____________
<br />Propane Gas Supply Pressure
<br />(from source)
<br />Natural Gas Manifold Pressure
<br />(min-max)_______________
<br />Propane Gas Manifold Pressure
<br />(min-max)
<br />Minimum Flow Rate
<br />Cold Water Inlet
<br />at
<br />□LI
<br />/
<br />4V
<br />Front View
<br />I!
|