My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
SU0005295_ENG DES PLN
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
N
>
99 (STATE ROUTE 99)
>
10600
>
2600 - Land Use Program
>
SU-91-12
>
SU0005295_ENG DES PLN
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/19/2024 1:52:16 PM
Creation date
9/8/2019 12:49:13 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2600 - Land Use Program
FileName_PostFix
ENG DES PLN
RECORD_ID
SU0005295
PE
2611
FACILITY_NAME
SU-91-12
STREET_NUMBER
10600
Direction
N
STREET_NAME
STATE ROUTE 99
City
LODI
APN
08607035
ENTERED_DATE
8/15/2005 12:00:00 AM
SITE_LOCATION
10600 N HWY 99
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\sballwahn
Supplemental fields
FilePath
\MIGRATIONS\N\HWY 99\10600\SU-91-12\SU0005295\ENG DES PLN.PDF
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
2
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
1 <br /> SEPTICSYSTEM CONSTRUCTION <br /> All Septic system requirements must be in accordance with the San Joaquin County Environmental Health Sewage Standards. <br /> For gravity systems, the house pad must be raised to permit gravity flow through both septic tanks and into leach field. <br /> The double septic system design shown on this plan must comply with the following:(See. 10 Sewage Standards.) MIN.25'DEEP <br /> SEEPAGE PITS(TVP.) <br /> Minimum distance from well to seepage pits 150' <br /> Minimum distance from trenches to well 100' <br /> Minimum distance from foundations,driveways and pools 10' <br /> Maximum length of individual leach line 100' <br /> Maximum width of trench 24" <br /> Maximum grade of line 3"per 100' <br /> Preferable grade of line 2"per 100' <br /> Distance between lines 10'edge to edge <br /> Minimum depth of rock below approved perforated pipe 12" <br /> Minimum depth of rock over approved perforated pipe 2" <br /> Maximumdepth of trench 42" <br /> Minimum distance between leach line and septic tank 5' LEACHLINES AND TRENCHES <br /> Maximum soil cover over leach line 24" (TYR-MIN.10'EDGE TO EDGE) <br /> Minimum soil cover over leach line 6" <br /> During leachfield construction,the sidewalls and floors of the leachline trenches most be scarified to open smeared soil surfaces possibly <br /> caused from the backhoe excavations. Seepage pits are normally scarified by a"cleat"on the outside of the auger flight All excavations <br /> should be inspected by a representative from San Joaquin County Public Health Services Department Environmental Health Division, <br /> before placement of drain rock. Telephone at least 48-hours in advance of inspection (209) 468-3284. <br /> Leachfield areas cannot be driven or parked over,and no structures can be built over these areas. Final grading of the leachfields most <br /> be such that drainage water from domestic irrigation or rainfall cannot collect and pond over the leachfields.Only grasses and small <br /> shrubs may be planted over the fields,with trees and large shrubs planted at least 15 feet away. The designated replacement area most <br /> remain as such,with no permanent structures built in this area z <br /> SEPTIC SYSTEM MAINTENANCE <br /> The septic system installed for the respective residence most consist of a dual leachfield system in accordance with San Joaquin Sewage <br /> Standards,Section 10.1.For the system to have maximum theoretical longevity,the leachfields most be manually switched between DISTRIBUTION <br /> each other on an annual basis.This can be accomplished with a push-pull"gate"valve,which will be on each of the two effluent lines BOX TYP. <br /> exiting the secondary septic tank It may be a requirement by the Environmental Health Department that the valves be located within ( ) o SECONDARY SEPTIC TANK o o PHI M1igRy <br /> the second compartment of the secondary tank. This second compartment must also have an installed filter. BULL RUN VALVE o (SEE ATTACHED NOTES) (OR) o o TANK <br /> The Environmental Health Department will require that the tanks be pumped every three years. Therefore,access to the tanks bypumper (IN CHRISTIE BOX) <br /> Woks mot be maintained.Since the septic systems will be installed in fare-grained clay soils,sodium from a water softener may hasten <br /> the clogging mechanisms of this soil type,which may lead to septic system failure. Therefore,water softeners should be avoided or o PRIMARY SEPTIC TANK <br /> limited in use. Water from domestic irrigation or rainfall must not be allowed to congregate in the leachfield areas. <br /> By signing below,the homeowner has read and understands the construction and maintenance procedures,as stated above and agrees <br /> to perform these recommended procedures. This information must be transferred to a buyer upon We of the applicable residences. <br /> QPOFESS 0Nq <br /> SIGNED PRINTED NAME DATE y,QW.01 '+ZA HOUSE <br /> DOUBLE SYSTEM LEACHFIELD REQUIREMENTS <br /> IN ACCORDANCE WITH SAN JOAQUIN COUNTY SEWAGE STANDARDS 4 Exp.151.07 r} <br /> J} <br /> Tic \e �1�p <br /> Leachline Length III) Size of Primary and No.and Dia.(in.) 4rEOF CALIFOP PLAN VIEW <br /> No.of Bedrooms Requirements Secondary Septic Tanks of Seepage Pits No.and Length(ft.)of Leachlines <br /> 3 300 n 1200+1200 gals 242'(160 ft eq.) 2-70 ft 1so•+140'=300' TYPICAL DOUBLE SEPTIC SYSTEM DESIGN PLATE <br /> q 400 ft 1600+1600 gals 342'(240 R.eq.) 3-55 ft 240'+165'=405' <br /> 5 500 R 2000+2000 gals 3-42'(240 ft eq.) 3.85 R 240'+255'-485' �� K L E I N F E L D E R HEATHER MOOR ESTATES 1 <br /> 6 600 ft 2000+2000 gals 442'(320 R eq.)) 4-70 ft 1320'+280'=600') UNIT No.2 <br /> (Except for septic tank sizes,all requirements above pertain to a single leachfield and therefore must be doubled). CATE PRODUCED:1011612001 IDATEREVISED: SAN JOAQUIN COUNTY,CALIFORNIA <br /> PROD.NO.:20-2921-02 FILENAME:20110620.FH9 <br /> NISMM1Wer.Mc.NMI <br />