My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
Y
>
YOSEMITE
>
1434
>
2300 - Underground Storage Tank Program
>
PR0231465
>
COMPLIANCE INFO_2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/20/2020 1:53:30 PM
Creation date
7/20/2020 11:29:27 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2018
RECORD_ID
PR0231465
PE
2361
FACILITY_ID
FA0003739
FACILITY_NAME
Colonial Energy CE 40134 (DBA Power Mart)
STREET_NUMBER
1434
Direction
W
STREET_NAME
YOSEMITE
STREET_TYPE
Ave
City
Manteca
Zip
95337
CURRENT_STATUS
01
SITE_LOCATION
1434 W Yosemite Ave
P_LOCATION
04
P_DISTRICT
005
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
186
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN J 0 A Q U I N Environmental Health Department <br /> .o <br /> 2 i <br /> Uy'! <br /> ' ` COUNTY Linda Turkatte, REHS, Director <br /> N -.... P. <br /> Greatness grows here. Kasey Foley,REHS,Assistant Director <br /> 'gGIFORa <br /> PROGRAM COORDINATORS <br /> Robert McClellon,REHS <br /> Jeff Carruesco,REHS,RDI <br /> October 03, 2018 Rodney Estrada,REHS <br /> Willy Ng,REHS <br /> Muniappa Naidu,REHS <br /> RONNIE LEWIS <br /> d <br /> NUCLEUS PUMP SERVICES <br /> 601 1ST AVENUE, SUITE B 6copy <br /> SACRAMENTO, CA 95818 <br /> Re: COLONIAL ENERGY CE 40134(DBA POWER Amended-SR0078235 <br /> 1434 W YOSEMITE AVE <br /> MANTECA, CA 95337 <br /> The San Joaquin County Environmental Health Department(EHD)has completed the review of the amended permit <br /> application for a permit to convert the existing midgrade UST to diesel, to disconnect and install an iron cap on <br /> midgrade vapor recovery piping inside the submersible turbine pump sump(STP)for diesel conversion, replace four <br /> existing dispensers with two Ovation (3+0)and two Ovation (3+1)models, install Bravo conversion frames on all four <br /> under dispenser containments(UDCs), install FE Petro STP-MLD-D leak detector on the converted diesel tank(no <br /> concrete breaking was proposed or approved under this permit) on the underground storage tank(UST)system at the <br /> above noted address. The permit has been approved with the following conditions: <br /> 1. Contact the local fire department and the San Joaquin Valley Air Pollution Control District for any <br /> applicable permits and requirements. <br /> 2. Any changes in information and scope of work must be submitted to EHD for approval prior to <br /> commencing work. All new addenda supersede the previous ones. <br /> 3. Contact Zuna Barker at(209)953-7311 to arrange the following appointments(a 48-hour notice <br /> is required for inspection appointments). <br /> • Sensor functionality: Functionality of the monitoring system must be verified to ensure that <br /> monitoring has been restored to meet the requirements of Title 23 California Code of Regulations <br /> and the Health&Safety Code. A copy of the alarm history shall be printed prior to performing <br /> the"cold start"of the monitoring system and made available at the time of EHD inspection. <br /> • Leak detector test: Leak detector(diesel tank)must be tested to confirm that the device can detect a leak of 3 <br /> gallons per hour at 10 psi. <br /> • Verification of Bravo conversion frames installation, per the manufacturer's installation instructions <br /> • Verification of the dispenser footprints contained by the under dispenser containment sumps <br /> (UDCs) <br /> Visual inspection of the piping within the dispensers for any leaks and to identify where piping has been capped off <br /> • Secondary containment testing: a 24-hour hydrostatic test(or equivalent)on impacted sumps <br /> (including any UDCs,where piping was capped off <br /> • Provide hazardous waste manifest(s)for tank and piping rinsate within 180 days of waste <br /> generation <br /> Please be aware that the facility cannot operate the UST system prior to the EHD inspection <br /> and approval. <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />
The URL can be used to link to this page
Your browser does not support the video tag.