Laserfiche WebLink
TENANT IMPROVEMENT744 WEST HAMMER LANE, STOCKTON, CA 95207CLIENT: SMART & FINAL600 CITADEL DRIVECOMMERCE, CA 90040Tel. No.: (323) 869-7895Contact: PETE CALDERONELECTRICAL:INNOVATIVE DESIGN ENGINEERS1106 WEST MAGNOLIA BLVD. BURBANK, CA 91506Tel. No.: (818) 842-7285Contact: MEL FAJARDOMECHANICAL &HUSSMANN13770 RAMONA AVENUE, CHINO, CA91710Tel. No.: (909) 590-4910Fax. No.: (909) 590-5113Contact: MICHELLE EVENS-LINDLEYPLUMBING:MBSE31332 VIA COLINAS SUITE 112 WESTLAKE VILLAGE, CA 91362Tel. No.: (818) 735-5551Fax. No.: (818) 735-5554Contact: BILL BOOTHABBREVIATIONSSHEET INDEXADDENDUM <br />BULLETIN - 00/00/00SHT#DESCRIPTIONA123GENERALT1.0TITLE SHEETDIRECTORYPROJECT DATA∠LEGAL JURISDICTION:CITY OF STOCKTONBUILDING CODE:1. CONCRETE SLAB PATCH BACK IN AREAS.2. NEW INTERIOR PARTITION WALLS.3. INSTALL NEW COOLER PANELS (BY CUSTOM COOLER).4. INSTALL NEW REFRIGERATED CASES.5. INSTALL NEW PLUMBING LINES & FIXTURES.6. INSTALL NEW LIGHTING & ELECTRICAL.SCOPE OF WORKGENERAL REQUIREMENTSARCHITECTURALA4.0ARCHITECTURAL DETAILSA7.0REFLECTED CEILING PLAN1st SUBMITTAL <br />2nd SUBMITTALELECTRICALMECHANICALPLUMBINGREFERENCE SITE PLANAS1.0FLOOR PLANA1.03rd SUBMITTAL2016 CALIFORNIA BUILDING CODE2016 CALIFORNIA ELECTRICAL CODE2016 CALIFORNIA MECHANICAL CODE2016 CALIFORNIA PLUMBING CODE2016 CALIFORNIA FIRE CODE2016 CALIFORNIA TITLE 24 ENERGY REQUIREMENTS2016 GREEN BUILDING CODEE-1.0SYMBOLS, LUMINAIRE SCHED. & NOTESE-2.0LIGHTING PLANE-4.0ROOF PLAN - ELECTRICALM1.1EQUIPMENT SCHEDULEM1.2HVAC FLOOR PLANM1.2AHVAC ROOF PLANP100PLUMBING NOTESP101PLUMBING SCHEDULE & DETAILSREFRIGERATIONR1FIXTURE FLOOR PLANR2PLUMBING FLOOR PLANR3REFRIGERATION FLOOR PLANR4HEALTH DEPT. NOTEHOT & COLD RUNNING WATER, WASTE DISPOSAL, PLUMBING (TOILETS), ELECTRICITYAND/OR GAS WILL BE PROVIDED AT ALL TIMES WHEN THE FOOD FACILITY IS OPENED FORBUSINESS DURING THE REMODEL.ALL FOODS AND FOOD CONTACT SURFACES WILL BE PROTECTED FROMCONTAMINATION DURING REMODELING.BID - 00/00/00E-5.0E-5.1E-6.0TITLE 24 - CERTIFICATE OF COMPLIANCECONSTRUCTION SET <br />ADDENDUMB <br />4SINGLE LINE DIAGRAMDETAILSE-7.0E-3.0POWER PLANELECTRICAL FLOOR PLANA8.0DOOR & ROOM FINISH SCHEDULEA10.0FIXTURE & EXIT PLANVICINITY MAPASSESSOR'S PARCEL NUMBER8102016ZONINGOCCUPANCY GROUPMCONSTRUCTION TYPEIII-B; FULLY SPRINKLEREDNUMBER OF STORIES1 STORYCG - COMMERCIAL, GENERAL1.ALL WORK AND MATERIALS SHALL CONFORM WITH THE APPLICABLE STANDARDS OFTHE 2016 CALIFORNIA BUILDING CODE (C.B.C.), A COPY SHALL BE MADE AVAILABLE ATTHE PROJECT SITE AT ALL TIMES BY THE GENERAL CONTRACTOR, INCLUDINGAMERICAN WITH DISABILITIES ACT (A.D.A.) REQUIREMENTS, CALIFORNIA PLUMBINGCODE (C.P.C.), CALIFORNIA MECHANICAL CODE (C.M.C.), CALIFORNIA ELECTRICAL CODE(C.E.C.), AND LATEST EDITIONS AND OTHER APPLICABLE STATE "AMENDMENTS ASADOPTED BY THE GOVERNING CITY OR COUNTY, AS WELL AS LOCAL GOVERNINGAGENCY ORDINANCES, LAWS, RULES, REGULATIONS AND PROJECT CONDITIONS OFAPPROVAL. NOTHING IN THESE DRAWINGS SHALL BE CONSTRUED TO PERMIT WORKNOT CONFORMING TO THESE CODES, STANDARDS OR REQUIREMENTS.2.A SEPARATELY BOUND PROJECT MANUAL / SPECIFICATIONS AND THE OWNER'S SCOPEOF WORK ARE A PART OF THESE DRAWINGS AND CONTRACT DOCUMENTS. INCLUDINGTHE OWNERS, SMART & FINAL INC.,"GENERAL CONDITIONS OF THE CONTRACT FORCONSTRUCTION". LATEST EDITION, WHICH IS MADE A PART OF THESE DRAWINGS AS ITAPPLIES TO THE OWNER, CONTRACTOR, AND ARCHITECT AND ALL MATTERS PERTAININGTO THE CONSTRUCTION WORK IMPLIES FULL ACCEPTANCE OF THESE GENERALREQUIREMENTS.3.CONTRACTOR SHALL VISIT THE SITE, FAMILIARIZE HIMSELF WITH EXISTING CONDITIONSAND REVIEW AND UNDERSTAND THE REQUIREMENTS OF THE CONSTRUCTION PLANSAND OF THE CONTRACT DOCUMENTS. CONTRACTOR IS RESPONSIBLE TO VERIFY ALLEXISTING ON-SITE AND OFF-SITE CONDITIONS INCLUDING ALL DIMENSIONS, GRADES,ELEVATIONS, SOILS AND EARTHWORK CONDITIONS WITH RESPECT TO THE WORKDESCRIBED ON THESE CONSTRUCTION DRAWINGS THROUGHOUT THE DURATION OFCONSTRUCTION. ANY DISCREPANCIES AND/OR UNEXPECTED CONDITIONS THATEFFECT OR CHANGE THE WORK DESCRIBED HEREIN SHALL BE BROUGHT TO THEARCHITECT'S ATTENTION IMMEDIATELY UPON NOTICE. CONTRACTOR SHALL NOTPROCEED WITH ANY OF THE WORK IN THE AREA OF DISCREPANCIES UNTIL ALL SUCHDISCREPANCIES ARE RESOLVED. IF THE CONTRACTOR CHOOSES TO DO SO, AND FAILSTO NOTIFY THE ARCHITECT IN A TIMELY MANNER, THEN IT IS UNDERSTOOD, THAT THECONTRACTOR SHALL BE PROCEEDING AT HIS OWN RISK AND WILL ASSUME ALLLIABILITIES AND INCUR ALL COSTS TO RESOLVE THE ISSUE TO THE ACCEPTANCE OFTHE ARCHITECT, OWNER AND/OR GOVERNING AGENCY. WRITTEN DIMENSIONS SHALLTAKE PRECEDENCE OVER SCALE ON THE DRAWINGS. DO NOT SCALE DRAWINGS.CONTRACTOR SHALL BE RESPONSIBLE FOR ALL CORRECTIONS AND REPAIRSREQUIRED DUE TO HIS FAILURE TO DO SO, COST OF CORRECTING WORK BASED ONMISINTERPRETATION BY CONTRACTOR OF UNREPORTED DISCREPANCIES SHALL BEBORNE BY THE CONTRACTOR.4.CONTRACTOR SHALL VISIT THE SITE PRIOR TO COMMENCING WITH THE WORK TODETERMINE IF ANY UTILITIES ARE REQUIRED TO BE REMOVED AND RELOCATED ANDSHALL NOTIFY, IN WRITING, THE ARCHITECT AND UTILITY COMPANY. CONTRACTOR SHALLFIELD VERIFY AND INCLUDE ANY AND ALL DEMOLITION NECESSARY TO COMPLETE ALLIMPROVEMENT WORK IN THE CONTRACT AND SHALL OBTAIN ALL NECESSARY PERMITSTO PERFORM THE PROJECT WORK OPERATION AREA A PART OF THIS CONTRACT.5.THE PLUMBING, MECHANICAL, ELECTRICAL, REFRIGERATION, AND DECOR DRAWINGS ARESUPPLEMENTARY TO THE ARCHITECTURAL DRAWINGS. IT SHALL BE THE RESPONSIBILITYOF THE GENERAL CONTRACTOR TO CHECK WITH THE ARCHITECTURAL DRAWINGSBEFORE THE INSTALLATION OF PLUMBING, MECHANICAL, REFRIGERATION, ELECTRICALWORK OR DECOR. ANY DISCREPANCY BETWEEN THE ARCHITECTURAL AND THECONSULTANTS' DRAWINGS SHALL BE BROUGHT TO THE ARCHITECT'S ATTENTION FORCLARIFICATION, AND WORK INSTALLED IN CONFLICT WITH THE ARCHITECTURALDRAWINGS SHALL BE CORRECTED BY THE GENERAL CONTRACTOR AT HIS OWN EXPENSE,AND AT NO EXPENSE TO THE OWNER, ARCHITECT, OR CONSULTANTS.6.ABBREVIATIONS THROUGHOUT THE DRAWINGS ARE THOSE IN COMMON USE. ARCHITECTWILL DEFINE INTENT OF ANY QUESTION.7.THE INSTALLATION OR OPERATION OF THE FIRE SPRINKLER SYSTEMS SHALL BE PLANCHECKED AND APPROVED BY THE FIRE DEPARTMENT PRIOR TO INSTALLATION.8.ALL COST FOR NON-STRUCTURAL RELATED INSPECTIONS, AND TESTS SHALL BE THERESPONSIBLITY OF THE GENERAL CONTRACTOR UNLESS NOTED OTHERWISE IN THESPECIFICATIONS / PROJECT MANUAL.CHECKSTANDS (TABLE IIB-2)REQUIRED: FOR 5-8 CHECKSTANDS, PROVIDE 2 ACCESSIBLE CHECKSTANDSPROVIDED: 6 CHECKSTANDS, 2 ACCESSIBLE CHECKSTANDS (CHECKSTANDS #1 & 2)9.CONTRACTOR SHALL PROVIDE PUBLIC PROTECTION TO PERSONS AND PROPERTYDURING CONSTRUCTION AS NECESSARY PER CITY OR COUNTY CODE REQUIREMENTS.CONTRACTOR SHALL ASSUME SOLE AND COMPLETE RESPONSIBILITY FOR ALL JOB SITECONDITIONS INCLUDING THE SAFETY OF PERSONS AND PROPERTY AND THEIRPROTECTION FROM DAMAGE, FIRE, INJURY OR LOSS, INCLUDING COMPLIANCE WITHAPPLICABLE O.S.H.A. SAFETY STANDARDS. THIS REQUIREMENT SHALL INCLUDE SUCHPRECAUTIONARY MEASURES TO PROVIDE AND CONSTRUCT TEMPORARY CONSTRUCTIONFENCES, COVERED WALKWAYS, (AS REQUIRED BY THE CITY) BARRICADES, SCAFFOLDING,ETC. AND SHALL APPLY CONTINUOUSLY DURING THE COURSE OF CONSTRUCTION OFTHIS PROJECT AND NOT BE LIMITED TO NORMAL WORKING HOURS. IT IS UNDERSTOODTHAT THE ARCHITECT AND CONSULTANT' JOB SITE OBSERVATIONS ARE NOT INTENDEDTO INCLUDE THE ADEQUACY OF THE CONTRACTOR'S SAFETY MEASURES. THECONTRACTOR SHALL DEFEND, INDEMNIFY AND HOLD THE OWNER AND ARCHITECTHARMLESS FROM ANY AND ALL LIABILITY, REAL OR ALLEGED, IN CONNECTION WITH THEPERFORMANCE OF WORK ON THIS PROJECT, EXCEPTING FOR LIABILITY ARISING FROMTHE SOLE NEGLIGENCE OF THE OWNER, ARCHITECT, OR ENGINEERS.10.IF THERE ARE TRENCHES OR EXCAVATIONS FIVE FEET (5'-0"), OR MORE IN DEPTH INTOWHICH A PERSON IS REQUIRED TO DESCEND, CONTRACTOR SHALL OBTAIN NECESSARYPERMIT FROM THE STATE OF CALIFORNIA DIVISION OF INDUSTRIAL SAFETY PRIOR TOISSUANCE OF BUILDING PERMIT.11.CONTRACTOR SHALL VERIFY, IN FIELD, ALL ELEVATIONS, FLOW LINES, EXISTINGCONDITIONS, AND POINTS OF CONNECTION WITH ADJOINING PROPERTY. ANYDISCREPANCIES SHALL BE CALLED TO THE ATTENTION OF THE ARCHITECT BEFOREPROCEEDING WITH WORK. CONTRACTOR SHALL OBTAIN WRITTEN AUTHORIZATIONFROM THE ADJOINING PROPERTY OWNER PRIOR TO COMMENCING ANY WORK WHICHREQUIRES USE OF, OR ANY IMPROVEMENTS TO THEIR PROPERTY.12.VEHICULAR ACCESS MUST BE PROVIDED AND MAINTAINED SERVICEABLE THROUGHOUTTHE ENTIRE CONSTRUCTION PERIOD. ALL CONSTRUCTION WORK PROVIDED FOR HEREINIS TO BE CONSTRUCTED AND FINISHED IN EVERY PART IN A GOOD AND SUBSTANTIALMANNER AND IN ACCORDANCE WITH THE DRAWINGS AND SPECIFICATIONS, THE FULLINTENT OF THE SAME. ANY WORK REQUIRED BY LAW, BUT WHICH MAY NOT BESPECIFICALLY MENTIONED HEREIN, SHALL BE PERFORMED BY THE CONTRACTOR INACCORDANCE WITH THE LAWS OF CITY, COUNTY, DISTRICT, OR STATE UNDER WHICHJURISDICTION WAY COME AND COST SHALL BE BORNE BY THE CONTRACTOR. ANY SUCHEXTRA WORK SHALL BE PERFORMED IN CONFORMANCE WITH THE PLANS; BOTH AS TOTHE MANNER AND APPEARANCE. ALL WORK SHALL BE PERFORMED IN ACCORDANCEWITH CURRENT EDITION OF I.C.C., AS REQUIRED BY GOVERNING AGENCIES.13.SOLELY AS A CONVENIENCE TO THE OWNER, THE ARCHITECT MAY INCLUDE DOCUMENTSPREPARED BY CERTAIN OWNER'S CONSULTANTS / VENDORS (OR INCORPORATE THERECOMMENDATIONS OF SAID CONSULTANTS / VENDORS IN DOCUMENTS PREPARED BYTHE ARCHITECT) WITH IN THE SET OF DOCUMENTS ISSUED BY THE ARCHITECT; IT BEINGEXPRESSLY UNDERSTOOD THAT, BY SAID ISSUANCE, THE ARCHITECT ASSUMES NOLIABILITY FOR THE SERVICES OF SAID CONSULTANTS / VENDORS.17.ALL CONTRACTORS, SUB OR GENERAL BIDDING OR CONSTRUCTING ANY PORTION OFTHIS PROJECT SHALL BE HELD RESPONSIBLE TO REVIEW AND INCLUDE IN ANY BIDSUBMITTED ALL OTHER DRAWINGS AND SPECIFICATIONS WHICH FORM A PART OF THESECONSTRUCTION DOCUMENTS INCLUDING, BUT NOT LIMITED TO ARCHITECTURALGENERAL NOTES, STRUCTURAL, AIR CONDITIONING, PLUMBING, AND ELECTRICAL ANDEQUIPMENT PLAN AS MAY APPLY TO SAID TRADE.18.PROVIDE SECURITY AND SAFETY BARRICADES AS REQUIRED.20.CONSTRUCTION DUST CONTROL: DURING CONSTRUCTION DUST CONTROL MEASURESSHALL BE REQUIRED. GRADING WILL BE DISCONTINUED DURING FIRST-STAGE SMOGALERTS AND SUSPENDED DURING PERIODS OF HIGH WIND (I.E. OVER 15 MILES PERHOUR). ALL HAULING TRUCKS SHALL HAVE LOADS COVERED OR WETTED AND LOADEDBELOW THE SIDEBOARDS TO MINIMIZE DUST. (APPLIES TO DEMOLITION, GRADING &CONSTRUCTION)14.CONTRACTOR TO REFER TO OWNER'S CONSULTANT'S / VENDOR'S DRAWINGS FORCOORDINATION AND RESPONSIBILITY OF WORK UNDER HIS CONTRACT.15.ALL FLOORS IN PUBLIC AREAS SHALL BE OF NON-SLIP SURFACE IN COMPLIANCE WITHTHE HEALTH AND SAFETY CODES OF THE STATE OF CALIFORNIA.16THIS BUILDINGS IS FIRE SPRINKLERED THROUGHOUT.A. EXTEND THE FIRE SPRINKLER SYSTEM TO ALL AREAS OF THE BUILDING.B. PROVIDE PLANS FOR FIRE SPRINKLER WORK TO THE CITY FIRE DEPARTMENT AND TOTHE PLUMBING DIVISION FOR APPROVAL PRIOR TO INSTALLATION.C. THE GENERAL CONTRACTOR SHALL PROVIDE A CERTIFICATE OF COMPLETION ISSUEBY THE SPRINKLER CONTRACTOR.D. SEPARATE PERMIT IS REQUIRED FOR FIRE SPRINKLER SYSTEM MODIFICATIONS. (PRIORTO START OF INSTALLATION)E. GENERAL CONTRACTOR TO PERFORM / MAINTAIN 5 YEAR CERTIFICATION AND TESTINGOF SPRINKLER SYSTEM.19.ALL DIMENSIONS ON THE DRAWINGS TAKE PRECEDENCE OVER SCALE.21.THE CONSTRUCTION SHALL NOT RESTRICT A FIVE-FOOT CLEAR AND UNOBSTRUCTEDACCESS TO ANY WATER OR POWER DISTRIBUTION FACILITIES (POWER POLES,PULL-BOXES, TRANSFORMER, VAULTS, PUMPS, VALVES, METERS, APPURTENANCES, ETC.)OR THE LOCATION OF HOOK-UP. THE CONSTRUCTION SHALL NOT BE WITHIN TEN FEETOF ANY POWER LINES-WHETHER OR NOT THE LINES ARE LOCATED ON THE PROPERTY.FAILURE TO COMPLY MAY CAUSE CONSTRUCTION DELAYS AND/OR ADDITIONALEXPENSES.22.ALL APPROVED SEISMIC GAS SHUTOFF VALVES WILL BE INSTALLED ON THE FUEL GASLINE ON THE DOWN STREAM SIDE OF THE UTILITY METER AND BE RIGIDLY CONNECTEDTO THE EXTERIOR OF THE BUILDING OR STRUCTURE CONTAINING THE FUEL GASPIPING.(PER ORDINANCE 178,158) (INCLUDES COMMERCIAL ADDITIONS AND WORK OVER$10,000.) SEPARATE PLUMBING PERMIT IS REQUIRED.23.WHEN ARCHITECT AND CONSULTING ENGINEERS DRAWINGS AND STANDARDS DIFFER,THE MOST RESTRICTIVE SHALL PREVAIL, UNLESS THE G.C. OR HIS SUB-CONTRACTORSBRING THEM TO THE ARCHITECT'S ATTENTION DURING THE BID PROCESS.24.PROVIDE ULTRAFLUSH WATER CLOSETS FOR ALL NEW CONSTRUCTION. EXISTINGSHOWERHEADS AND TOILETS MUST BE ADOPTED FOR LOW WATER CONSUMPTION.25.A COPY OF THE EVALUATION REPORT AND/OR CONDITION OF LISTING SHALL BE MADEAVAILABLE AT THE JOB SITE.SPECIAL REQUIREMENTS1. MODIFICATION OF THE EXISTING FIRE SPRINKLER SYSTEM IS DESIGN-BUILT BY THE G.C.AND HIS FIRE SPRINKLER SUB-CONTRACTOR.2. THE FIRE SPRINKLER 5 YEAR SERVICE AND MAINTENANCE MUST BE CURRENT BYCOMPLETION OF PROJECT.SEPARATE PERMIT1. INTERIOR SALES SHELVING / RACKING.R5AR6ACASE DETAILSEXIT WIDTH REQUIRED:438 X 0.2 = 87.6"EXIT WIDTH PROVIDED: 001 (72") + 002 (72") + 003 (72") = 216"EXITS PROVIDED: 3 EXITSNUMBER OF EXITS REQUIRED: 2 EXITS PER 2016 CBC TABLE 1006.3.1TABLE 1016.2MAXIMUM TRAVEL DISTANCE REQUIRED 250'OCCUPANCY WITHOUT SPRINKLERS WITH SPRINKLERSTYPE M 200' 250'TOTAL OCCUPANTS: 438EXITING DIAGRAM:T2.0A9.0ROOF PLANP102WASTE & VENT FLOOR PLANSMART & FINAL30,032 S.F.OCCUPANCY LOAD (TABLE 1004.1.2):USEALLOWANCE / OCCUPANTAREAOCCUPANTSSALES24,130 S.F.60 SF/OCCSTORAGE300 SF/OCCCOOLER/FREEZER300 SF/OCCBUSINESS100 SF/OCCBREAKROOM15 SF/OCCTOTAL OCCUPANTS:4384022,005 S.F.71,931 S.F.7584 S.F.6 220 S.F.15ARCHITECT:MCG ARCHITECTURE111 PACIFICA, SUITE 280IRVINE, CA 92618Tel. No.: (949) 553-1117Fax. No.: (949) 474-7056Contact: AMBER CHARLEST3.0TYPICAL ADA NOTES2. BUILDING SIGNAGEREFRIGERATION:M1.3ELECTRICAL WIRING87.6" < 216", COMPLIESM1.4EQUIPMENT DETAILSM1.4AHOOD DETAILM1.4BFIRE BARRIER DETAILSPROVIDED: YESREQUIRED: YESREQUIRED: YESPROVIDED: YESMIN. PLUMBING FACILITIES REQUIRED (TABLE 4-1)ACCESSIBLE PLUMBING FACILITIESSEPARATE FACILITIESREQUIRED: 1PROVIDED: 1SERVICE SINK:PROVIDED: 2 (1 hi-lo)REQUIRED: 1REQUIRED: 1PROVIDED: 2DRINKING FOUNTAIN: (1 - 250)WATER CLOSETS - (1 - 100)REQUIRED: 1PROVIDED: 3WATER CLOSETS - (1 - 100)REQUIRED: 1PROVIDED: 3LAVATORIES - (1 - 200)REQUIRED: 1PROVIDED: 3LAVATORIES - (1 - 200)REQUIRED: 0PROVIDED: 1URINALS - (1 - 200)2016 CALIFORNIA PLUMBING CODE ANALYSIS50% MALE = 75 MALES50% FEMALE = 75 FEMALESPLUMBING ANALYSISOCCUPANCY LOAD (TABLE A):OCCUPANCYALLOWANCE / OCCUPANTAREAOCCUPANTSRETAIL30,032 S.F.200 SF/OCC150M1.1ACA GREEN BUILDING STANDARDSCALGREEN NOTESA6.1INTERIOR ELEVATIONS AND DETAILSA4.1ARCHITECTURAL DETAILSREFRIGERATION SCHEDULE3. A UL FIRE ALARM CERTIFICATE MUST BE CURRENT BY COMPLETION OF PROJECT.SLAB PLANA1.2MISC/HALLWAY- 832 S.F.-SMART & FINAL #393BUILDING DATA:R6BREFRIG. CASE AND COIL DETAILSPANEL SCHEDULES & NOTESP103SUPPLY PIPING FLOOR PLANENLARGED PLANSA6.0E-2.1LIGHTING PHOTOMETRIC PLANMEMSENERGY MANAGEMENT SYSTEMEQUIPMENT ROOMS300 SF/OCC 330 S.F.1DEMOLITION FLOOR PLANA1.1R5BPROTOCOL BUSSBAR AND BOARD ASSIGN.COOLER DETAILSA5.1COOLER LAYOUTA5.0A3.0EXTERIOR ELEVATIONSE-2.2LIGHTING PHOTOMETRIC PLANP104PLUMBING DETAILSPV101VACUUM PLUMBING FLOOR PLANPV102VACUUM NOTES & DETAILS0010020032 <br />1 <br />6 <br />' <br />- <br />6 <br />" <br /> <br />A <br />P <br />P <br />R <br />O <br />X <br />. <br /> <br />D <br />I <br />A <br />G <br />O <br />N <br />A <br />L <br />2 <br />1 <br />6 <br />' <br />- <br />6 <br />" <br />/ <br />3 <br /> <br />= <br /> <br /> <br />7 <br />2 <br />' <br />- <br />2 <br />"T1.0TITLE SHEETFilename:Sheet Title:Date:Scale:Project No.: Drawn By:Reviewed By:No.MCG ARCHITECTS 2018 ALL RIGHTS RESERVEDCSheet #:09-18-18Description18.452DateRevisions:Client:A Project for:Seal:TEAM600 CITADEL DRIVE,COMMERCE, CA 90040Tel. (323) 869 7500Fax (323) 869 7856TENANT IMPROVEMENT <br />STOCKTON, CA 95207 <br />SMART & FINAL #393 <br />744 WEST HAMMER LANE <br />AS NOTED10.22.181ST SUBMITTALSan Joaquin County Environmental Health Department 1868 E. Hazelton Ave. Stockton, CA 95205 (209) 468-3420 APPROVED WITH CONDITIONS For conditions, please see approval letter dated: Approved by:_______________________Date:_______________ 12-3-18Dec 03, 2018 Maribel Flohrschutz