Laserfiche WebLink
Environmental Health Department <br />Time In: <br /> 9:11 am <br /> 8:51 am <br />Time Out: <br />Program Element: 3611 - PUBLIC POOL/SPA - PRIMARY <br />Telephone: (510) 676-1966 Owner/Operator: DRIFTWOOD INVESTORS <br />Inspection Type: ROUTINE INSPECTION - Operating Permit <br />Address: 800 W GRANT LINE RD, TRACY 95376 <br />Date: 07/07/2021Name of Facility: DRIFTWOOD APARTMENTS <br />Swimming Pool Official Inspection Report <br />VIOLATIONS AND CORRECTIVE ACTIONS <br />Items listed on this report as violations do not meet the requirements set forth in the California Health and Safety Code section(s) 116043, 116040, & <br />116050. All violations must be corrected within specified timeframe. Violations that are classified as "MAJOR" pose an immediate threat to public health <br />and must be corrected immediately or be subject to closure pursuant to California Code of Regulations (Title 22) section 65545. <br /> #12 pH Level MAJOR <br />OBSERVATIONS: The pH is 8.0. Maintain pH level at the range of 7.2 to 7.8. Correct immediately. <br />Corrected on site - 1/4 gallon of acid was added on site. Re-check pH: 7.2 <br />CALCODE DESCRIPTION: Pool operator shall maintain pH between 7.2 and 7.8. (CCR 65530) <br /> #8 Pool and Deck Lighting <br />OBSERVATIONS: The pool light is on a sensor (unable to locate). Ensure that the pool light and GFI are in proper working <br />condition. <br />CALCODE DESCRIPTION: Pools used at night shall be equipped with underwater light fixtures that provide complete illumination of the <br />pool. When a pool is used at night, pool deck and emergency egress areas shall be provided with lighting. If underwater or deck lighting is <br />not operational, the pool operator shall post a sign in 4-inch letters stating "NO USE OF POOL ALLOWED AFTER DARK" and shall <br />secure the pool area and not permit any use of the pool after dark. (3115B) <br /> #18 Pool Shell and Tile <br />OBSERVATIONS: The pool plaster is pitted. Consider getting the pool re-plastered by next year. <br />CALCODE DESCRIPTION: Pool shells shall be white and have a smooth waterproof interior finish that will withstand repeated brushing, <br />and scrubbing. A spa pool may be finished in a light color other than white when approved by the enforcement agency. (CBC 3108B) <br /> #22 Skimmer Assembly <br />OBSERVATIONS: The skimmer is missing a float valve assembly. Provide a float valve assembly ASAP. <br />Corrected on site. <br />CALCODE DESCRIPTION: Pool shall be equipped to provide continuous skimming of the pool water. All parts of the skimmer shall be <br />maintained in accordance with manufacturer specifications. (CBC 3136B) <br />Page 1 of 2EHD 36-01 Rev. 09/16/2020 Swimming Pool OIR <br />FA0003225 PR0360344 SC001 07/07/2021 <br />1868 E. Hazelton Avenue | Stockton, California 95205 | T 209 468-3420 | F 209 464-0138 | www.sjgov.org/EHD