Laserfiche WebLink
SA N'tJ D A Q U I N Environmental Health Department <br /> —COUNTY <br /> Greorness grows here, Time In: 11.02 am <br /> Time Out: 11:20 am <br /> Swimming Pool Official Inspection Report <br /> Name of Facility: FLAG CITY RV RESORT Date: 07/13/2021 <br /> Address: 6120 W BANNER ST, LODI 95242 <br /> Owner/Operator: GILL, JASBIR FAMILY LMTD PRTSP Telephone: (209)339-8300 <br /> Program Element: 3611 -PUBLIC POOL/SPA-PRIMARY <br /> Inspection Type: ROUTINE INSPECTION -Operating Permit <br /> VIOLATIONS AND CORRECTIVE ACTIONS <br /> Items listed on this report as violations do not meet the requirements set forth in the California Health and Safety Code section(s)116043, 116040,& <br /> 116050. All violations must be corrected within specified timeframe. Violations that are classified as"MAJOR"pose an immediate threat to public health <br /> and must be corrected immediately or be subject to closure pursuant to California Code of Regulations(Title 22)section 65545. <br /> #8 Pool and Deck Lighting <br /> OBSERVATIONS:Light at deep end is inoperative. <br /> Provide functional light with operative GFI. <br /> CALCODE DESCRIPTION:Pools used at night shall be equipped with underwater light fixtures that provide complete illumination of the <br /> pool. When a pool is used at night,pool deck and emergency egress areas shall be provided with lighting. If underwater or deck lighting is <br /> not operational, the pool operator shall post a sign in 4-inch letters stating"NO USE OF POOL ALLOWED AFTER DARK"and shall <br /> secure the pool area and not permit any use of the pool after dark. (31158) <br /> #9 Ladders and Handrails <br /> OBSERVATIONS:Deep end hand rails are loose. <br /> Tighten. <br /> CALCODE DESCRIPTION:A means of entry and exit shall be provided at both the shallow and deep end of the pool.Ladders and <br /> handrails shall be corrosion resistant and shall be rigidly installed.At least one handrail shall extend from the deck to not less than a point <br /> above the top of the lowest step.Handrails shall be installed between 28 to 36 inches above the steps and deck. (CBC 311 1B)Pool <br /> operator shall keep ladders and handrails well maintained. (CCR 65535) <br /> #13 Cyanuric Acid Concentration <br /> OBSERVATIONS:Cyanuric acid is greater than 100ppm. <br /> Provide at 100ppm or less. <br /> Recommend draining pool an refilling with fresh water. <br /> CALCODE DESCRIPTION:Pool operator shall maintain cyanuric acid concentration between 0.0 ppm and 100 ppm. (CCR 65530) <br /> #36 Pressure and Vacuum Gauges <br /> OBSERVATIONS:The difference between the influent guage and effluent guage is 29psi. <br /> Recommend cleaning filter so that the difference is 10psi or less. <br /> CALCODE DESCRIPTION:Pressure and vacuum gauges shall be provided for each pump system. (CBC 31258) <br /> FA0016673 PR0524854 SCO01 07/13/2021 <br /> EHD 36-01 Rev.06/30/15 Page 1 of 2 Swimming Pool OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />