SAN J OA Q U I N Environmental Health Department <br /> COUNTY <br /> C, Time In: 8'10 am <br /> Greotness grows here. <br /> - Time Out: 9:30 am <br /> Swimming Pool Official Inspection Report <br /> Name of Facility: ST MARYS HIGH SCHOOL Date: 07/02/2020 <br /> Address: 5648 N EL DORADO ST, STOCKTON 95207 <br /> Owner/Operator: ST MARYS HIGH SCHOOL Telephone: (209)957-3340 <br /> Program Element: 3611 -PUBLIC POOL/SPA-PRIMARY <br /> Inspection Type: ROUTINE INSPECTION-Operating Permit <br /> VIOLATIONS AND CORRECTIVE ACTIONS <br /> Items listed on this report as violations do not meet the requirements set forth in the California Health and Safety Code section(s)116043,116040,& <br /> 116050. All violations must be corrected within specified timeframe. Violations that are classified as"MAJOR"pose an immediate threat to public health <br /> and must be corrected immediately or be subject to closure pursuant to California Code of Regulations(Title 22)section 65545. <br /> #7 Pool Deck <br /> OBSERVATIONS:There are gaps between pool coping and deck/concrete floor and some copings are damaged. <br /> Sea/replace these gaps/damage copings within three month. <br /> CALCODE DESCRIPTION:An unobstructed 4-foot wide deck of concrete or like material shall be provided and maintained flush with the <br /> top of the pool coping. Deck shall extend completely around the pool and shall further extend 4 feet on both sides and to the rear of any <br /> diving board,ADA device,orslide. (CBC 31148)Pool operatorshall keep the pool deck well maintained. (CCR 65535) <br /> #8 Pool and Deck Lighting <br /> OBSERVATIONS:Some underwater lights are not functioning. Repair/replace these non-functioning lights within three <br /> months. <br /> CALCODE DESCRIPTION:Pools used at night shall be equipped with underwater light fixtures that provide complete illumination of the <br /> pool. When a pool is used at night,pool deck and emergency egress areas shall be provided with lighting. If underwater or deck lighting is <br /> not operational, the pool operator shall post a sign in 4-inch letters stating"NO USE OF POOL ALLOWED AFTER DARK"and shall <br /> secure the pool area and not permit any use of the pool after dark. (3115B) <br /> #9 Ladders and Handrails <br /> OBSERVATIONS:The handrails at North end near 12'depth marker is loose. Tighten this handrails within one week. <br /> CALCODE DESCRIPTION:A means of entry and exit shall be provided at both the shallow and deep end of the pool. Ladders and <br /> handrails shall be corrosion resistant and shall be rigidly installed.At least one handrail shall extend from the deck to not less than a point <br /> above the top of the lowest step. Handrails shall be installed between 28 to 35 inches above the steps and deck. (CBC 3111B)Pool <br /> operator shall keep ladders and handrails well maintained. (CCR 65535) <br /> OVERALL INSPECTION NOTES AND COMMENTS <br /> OBSERVATIONS <br /> Flow rate: 1,058 gpm Chlorine: 3 ppm Temp: ° F <br /> Cyanuric acid: 0 ppm pH: 7.2 Combined chlorine: 0 ppm <br /> NOTES <br /> FA0002168 PRO527393 SCO01 07/02/2020 <br /> EHD 36-01 Rev.06/30/15 Page 1 of 2 Swimming Pool OR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sicehd.com <br />