Laserfiche WebLink
plugged with a silicone stopper. The sample should be the following data is recorded:air flow,temperature,and <br /> placed in a non-refrigerated,dry cooler with sufficient packing pressure at collection ports and gauges. <br /> to eliminate breakage during transport. Cooling samples will <br /> cause condensation of moisture,thereby distorting laboratory The sampling equipment consists of a sterilized,gas-tight, <br /> analysis. "Vaca-Sampler"stainless steel canister,and 1/4-inch- <br /> diameter polyethylene tubing approximately 2 feet in length. <br /> For quality control purposes,a duplicate air sample should <br /> be collected from each port. This sample is put on hold at The sampling ports are brass connections fitted with silicone <br /> the laboratory pending initial analysis. septa and threaded into a tapped hole in the system piping. <br /> The sampling procedure requires one end of the tubing to be <br /> Vapor samples are subject to very limited holding times, slipped over the sampling port and the other end over the <br /> typically 48 hours. Thus,care must taken to avoid delays in canister nozzle to acquire an air-tight connection. The <br /> submittal of vapor samples to the laboratory. In the event the actuator on top of the canister is depressed for 10 seconds. <br /> vapor samples cannot be submitted to the analytical At the end of the 10 seconds,the canister is disconnected <br /> laboratory on the same day they are collected,they are to be from the tubing and the tubing is disconnected from the <br /> temporarily stored in the dry,non-refrigerated,packed cooler sampling port. Immediately following the sample collection, <br /> until the very first opportunity for submittal well within the complete sampling information is recorded on the label on <br /> required holding time,taking into account the time needed for the air sampling canister(e.g.,sample ID,date,time, <br /> shipment to and receipt by the laboratory. location,and temperature). The sample is placed in a non- <br /> refrigerated,dry cooler with sufficient packing to ensure <br /> SOP-11 against damage during transport. Cooling samples will <br /> VAPOR SAMPLING:CANISTER SAMPLING TECHNIQUE cause condensation of any moisture within the air sample, <br /> thereby distorting laboratory analysis. <br /> Prior to vapor sampling,the vacuum system must reach a <br /> stabilized air flow(cubic feet per minute)for approximately 15 <br /> minutes. Prior to the actual collection of the vapor sample, <br /> For quality control purposes,a duplicate vapor sample case,this is the depth-to-water(DTW)indication and the <br /> should be collected from each sampling port. This sample is DTW measurement is made accordingly. The steady tone <br /> then put on hold at the laboratory pending the initial analysis. indicates floating liquid hydrocarbons(FLH). In this case,the <br /> To minimize the potential for cross-contamination between probe is slowly raised until the steady tone ceases. This is <br /> vapor samples,the polyethylene tubing,if not sample the depth-to-product(DTP)indication and the DTP <br /> dedicated,is thoroughly cleaned and rinsed. measurement is made accordingly. <br /> Vapor samples are subject to very limited holding times, The process of lowering and raising the probe must be <br /> typically 48 hours. Thus,care must taken to avoid delays in repeated several times to ensure accurate measurements. <br /> submittal of vapor samples to the laboratory. In the event the The DTW and DTP measurements are recorded on the <br /> vapor samples cannot be submitted to the analytical liquid-level data sheet. When FLH are indicated by the <br /> laboratory on the same day they are collected,they are to be probe's response,a product bailer is lowered partially <br /> temporarily stored in the dry,non-refrigerated,packed cooler through the FLH-water interface to confirm the FLH on the <br /> until the very first opportunity for submittal well within the water surface and as further indication of the FLH thickness, <br /> required holding time,taking into account the time needed for particularly in cases where the FLH layer is quite thin. This <br /> shipment to and receipt by the laboratory. measurement is recorded on the data sheet as"FLH <br /> thickness." <br /> SOP-12 <br /> MEASURING LIQUID LEVELS USING WATER LEVEL In order to avoid cross-contamination of wells during the <br /> METER OR INTERFACE PROBE liquid-level measurement process,wells are measured in the <br /> order of"clean"to"dirty"(where such information is <br /> Field equipment used for liquid-level gauging typically available). In addition,all measurement equipment is <br /> includes the measuring instrument(water-level meter or cleaned with solution and thoroughly rinsed with deionized <br /> interface probe)and product bailer(s). The field kit also water before use,between measurements in respective <br /> includes cleaning supplies(buckets,solution,spray bottles, wells,and at the completion of the day's use. <br /> and deionized water)to be used in cleaning the equipment <br /> between wells. SOP-13 <br /> SOIL VAPOR SAMPLING:"TEDLAR"BAG SAMPLING <br /> Prior to measurement,the instrument tip is lowered into the TECHNIQUE <br /> well until it touches bottom. Using the previously established <br /> top-of-casing or top-of-box(i.e.,wellhead vault)point,the The sampling equipment consists of a TedlarTm bag <br /> probe cord(or halyard)is marked and a measuring tape (available in 1,3,5,and 10 liter sizes),a diaphragm pump, <br /> (graduated in hundredths of a foot)is used to determine the and 3/16-inch-diameter polyethylene tubing(approximately 1 <br /> distance between the probe end and the marking on the foot long).The Tedlarl" bag should be fitted with an integral <br /> cord. This measurement is then recorded on the liquid-level valve for filling and sealing the bag after sampling.The <br /> data sheet as the"Measured Total Depth"of the well. diaphragm pump inlet and outlet are fitted with 3/16-inch <br /> hose barbs for attaching the sample tubing.Prior to vapor <br /> When necessary in using the interface probe to measure sampling,the soil vapor source(vapor screen,vapor <br /> liquid levels,the probe is first electrically grounded to either extraction well or manifold,etc.)must be isolated for <br /> the metal stove pipe or another metal object nearby. When sampling.A sample label with the sample number and date <br /> no ground is available,reproducible measurements can be and time of sample collection is prepared and placed on the <br /> obtained by clipping the ground lead to the handle of the Tedlar"I bag. <br /> interface probe case. <br /> If the sample is being collected from an operating vapor <br /> The probe tip is then lowered into the well and submerged in extraction system,the target vapor manifolds must be set up <br /> the groundwater. An oscillating(beeping)tone indicates the with sample ports that can be isolated without interrupting <br /> probe is in water. The probe is slowly raised until either the system operation. Prior to the actual collection of the vapor <br /> oscillating tone ceases or becomes a steady tone. In either sample,source data is recorded:air flow,temperature,and <br />