3) Provide 1/2"foam dielectric"superflexible"coaxial cable assembly <br /> for connecting the lighting arrester to the antenna. The cable shall <br /> be installed as one continuous length from the antenna"pigtail"to <br /> the in-line lighting arrester. Use Andrew FSJ1-50A 1/2" <br /> superflexible coax cable. <br /> 4) Provide miscellaneous hardware such as grounding kits, hanger - <br /> kits, and feed through assemblies. <br /> 5) The cable shall be carefully installed to prevent damage to the <br /> jacket and routed with a minimum bending radius of 6 inches. <br /> 6) Type "N" in-line connectors shall be utilized at the terminations <br /> and shall be protected from weather by a vapor-wrap application. <br /> Provide Type N connectors with weatherproof"0" ring seals, as <br /> recommended by the coaxial cable manufacturer. <br /> 7) Provide connector weatherproofing kits for outdoor exposed <br /> connectors and grounding strap attachments. <br /> 2.09 VIDEO SURVEILLANCE SYSTEM <br /> A. Video system shall consist of one video camera with power supplies, and all <br /> necessary wiring, conduit, mounting brackets and terminations required for <br /> installation. Camera System shall be Bullet Camera as supplied by 123cctv.com or -- <br /> approved equal. <br /> 1. Cameras System shall consist of Sony 1/3" CCD Color Bullet Camera. -- <br /> Cameras to have 3.6mm lens rated for outdoor weatherproof installation with <br /> mounting brackets and 0.2 lux sensitivity with automatic switchover to black <br /> and white. Cameras to have 12 volt DC power supply. Provide cabling for <br /> power and video signal to each location from Pedestal. <br /> 2.10 AUTOMATIC TRANSFER SWITCH <br /> A. SWITCH UNIT <br /> 1. The transfer switch unit shall be electrically operated and mechanically held. <br /> The electrical operator shall be a single solenoid mechanism, momentarily _ <br /> energized to minimize power consumption and heat generation. <br /> 2. ATS types utilizing components of molded-case circuit breakers,contactors,or <br /> parts thereof, are not acceptable. <br /> 3. The switch shall be true double-throw with inherently interlocked construction. <br /> The switch shall be mechanically interlocked to ensure only one of two <br /> possible positions, normal or emergency. <br /> 4. Wide contact gaps shall be provided to insure positive isolation of the normal <br /> and emergency power sources. -- <br /> 5. The switch shall be rated to withstand symmetrical short circuit current at the <br /> ATS terminals in combination with normal or emergencyfeeder breakers rated <br /> equal to or greater than RMS symmetrical amperes shown on Contract — <br /> Drawings. <br /> Division III-203 NEI Phase II Water and Sewer <br /> July 2007 CIP Nos. 7468, 7589, 7590 <br />