Laserfiche WebLink
SlurryPro CDP synthetic slurries shall be tested for conformance to the requirements shown in the following table: <br /> SLURRYPRO CDP <br /> KB Technoloizies Ltd. <br /> PROPERTY RE UIREMENT TEST <br /> Density(kg/m3) <br /> Mud Weight <br /> -during drilling less than or equal to (Density) <br /> 1075* API13B-1 <br /> Section 1 <br /> -prior to final <br /> cleaning less than or equal to <br /> -just prior to 1025* <br /> placing concrete <br /> Viscosity <br /> (seconds/liter) <br /> Marsh Funnel and <br /> -during drilling 53 to 127 Cup <br /> API 13B-1 <br /> Section 2.2 <br /> -prior to final <br /> cleaning less than or equal to <br /> -just prior to 74 <br /> placing concrete <br /> Glass Electrode pH <br /> H 6 to 11.5 Meter or pH Paper <br /> Sand Content <br /> (percent) Sand <br /> API 13B-1 <br /> -prior to final less than or equal to Section 5 <br /> cleaning 0.5 <br /> -just prior to <br /> placing concrete <br /> *When approved by the Engineer, slurry may be used in salt <br /> water, and the allowable densities may be increased up to <br /> 32 kg/m3. <br /> Slurry temperature shall be at least 4°C when tested. <br /> Contract No. 10-OM7104 <br /> 160 <br />