test batch concrete under slung will not be required. In addition to meeting the specified nominal penetration,the test batch <br /> shall meet the following requirements: <br /> A. For piles where the time required for each concrete placing operation, as submitted in the placing plan, will be <br /> 2 hours or less, the test batch shall demonstrate that the proposed concrete mix design achieves either a penetration <br /> of at least 50 mm or a slump of at least 125 mm after twice that time has elapsed. <br /> B. For piles where the time required for each concrete placing operation,as submitted in the placing plan,will be more <br /> than 2 hours,the test batch shall demonstrate that the proposed concrete mix design achieves either a penetration of <br /> at least 50 mm or a slump of at least 125 mm after that time plus 2 hours has elapsed. <br /> The time period shall begin at the start of placement. The concrete shall not be vibrated or agitated during the test <br /> period. Penetration tests shall be performed in conformance with the requirements in California Test 533. Slump tests shall <br /> be performed in conformance with the requirements in ASTM Designation: C 143. Upon completion of testing,the concrete <br /> shall be disposed of in conformance with the provisions in Section 7-1.13, "Disposal of Material Outside the Highway Right <br /> of Way,"of the Standard Specifications. <br /> The concrete deposited under slurry shall be carefully placed in a compact, monolithic mass and by a method that will <br /> prevent washing of the concrete. Concrete deposited under slung need not be vibrated. Placing concrete shall be a <br /> continuous operation lasting not more than the time required for each concrete placing operation at each pile,as submitted in <br /> the placing plan, unless otherwise approved in writing by the Engineer. The concrete shall be placed with concrete pumps <br /> and delivery tube system of adequate number and size to complete the placing of concrete in the time specified. The delivery <br /> tube system shall consist of one of the following: <br /> A. A tremie tube or tubes,each of which are at least 250 mm in diameter, fed by one or more concrete pumps. <br /> B. One or more concrete pump tubes,each fed by a single concrete pump. <br /> The delivery tube system shall consist of watertight tubes with sufficient rigidity to keep the ends always in the mass of <br /> concrete placed. If only one delivery tube is utilized to place the concrete, the tube shall be placed near the center of the <br /> drilled hole. Multiple tubes shall be uniformly spaced in the hole. Internal bracing for the steel reinforcing cage shall <br /> accommodate the delivery tube system. Tremies shall not be used for piles without space for a 250-mm tube. <br /> Spillage of concrete into the slurry during concrete placing operations shall not be allowed. Delivery tubes shall be <br /> capped with a watertight cap,or plugged above the slung level with a good quality,tight fitting,moving plug that will expel <br /> the slurry from the tube as the tube is charged with concrete. The cap or plug shall be designed to be released as the tube is <br /> charged. The pump discharge or tremie tube shall extend to the bottom of the hole before charging the tube with concrete. <br /> After charging the delivery tube system with concrete,the flow of concrete through a tube shall be induced by slightly raising <br /> the discharge end. During concrete placement, the tip of the delivery tube shall be maintained as follows to prevent reentry <br /> of the slurry into the tube. Until at least 3 in of concrete has been placed,the tip of the delivery tube shall be within 150 mm <br /> of the bottom of the drilled hole, and then the embedment of the tip shall be maintained at least 3 in below the top surface of <br /> the concrete. Rapid raising or lowering of the delivery tube shall not be permitted. If the seal is lost or the delivery tube <br /> becomes plugged and must be removed, the tube shall be withdrawn, the tube cleaned,the tip of the tube capped to prevent <br /> entrance of the slurry, and the operation restarted by pushing the capped tube 3 in into the concrete and then reinitiating the <br /> flow of concrete. <br /> When slurry is used, a fully operational standby concrete pump, adequate to complete the work in the time specified, <br /> shall be provided at the site during concrete placement. The slung level shall be maintained within 300 mm of the top of the <br /> drilled hole. <br /> A log of concrete placement for each drilled hole shall be maintained by the Contractor when concrete is deposited under <br /> slurry. The log shall show the pile location, tip elevation, dates of excavation and concrete placement, total quantity of <br /> concrete deposited, length and tip elevation of any casing, and details of any hole stabilization method and materials used. <br /> The log shall include a 215 mm x 280 mm sized graph of the concrete placed versus depth of hole filled. The graph shall be <br /> plotted continuously throughout placing of concrete. The depth of drilled hole filled shall be plotted vertically with the pile <br /> tip oriented at the bottom and the quantity of concrete shall be plotted horizontally. Readings shall be made at least at each <br /> 1.5 in of pile depth, and the time of the reading shall be indicated. The graph shall be labeled with the pile location, tip <br /> elevation, cutoff elevation, and the dates of excavation and concrete placement. The log shall be delivered to the Engineer + <br /> within one working day of completion of placing concrete in the pile. <br /> After placing reinforcement and prior to placing concrete in the drilled hole, if drill cuttings settle out of the slurry, the <br /> bottom of the drilled hole shall be cleaned. The Contractor shall verify that the bottom of the drilled hole is clean. <br /> If temporary casing is used,concrete placed under slurry shall be maintained at a level at least 1.5 in above the bottom of <br /> the casing. The withdrawal of casings shall not cause contamination of the concrete with slung. <br /> Contract No. 10-OM7104 <br /> 165 <br />