Laserfiche WebLink
An end anchor assembly (Type CA) for metal beam guard railing shall consist of an anchor cable, an anchor <br /> plate,a single anchor rod or double anchor rods,hardware and one concrete anchor. <br /> A rail tensioning assembly for metal beam guard railing shall consist of an anchor cable, an anchor plate, and <br /> hardware. <br /> The anchor plate,metal plates, steel foundation tubes and steel soil plate shall be fabricated of steel conforming <br /> to the requirements in ASTM Designation: A 36/A 36M. <br /> The anchor rods shall be fabricated of steel conforming to the requirements in ASTM Designation: <br /> A 36/A 36M,A 441 or A 572, or ASTM Designation: A 576,Grades 1018, 1019, 1021 or 1026. The eyes shall be <br /> hot forged or formed with full penetration welds. After fabrication, anchor rods with eyes that have been formed <br /> with any part of the eye below 870°C during the forming operation or with eyes that have been closed by welding <br /> shall be thermally stress relieved prior to galvanizing. The completed anchor rod, after galvanizing, shall develop a <br /> strength of 220 kN. <br /> In lieu of built-up fabrication of anchor plates as shown on the plans, anchor plates may be press-formed from <br /> steel plate,with or without welded seams. <br /> All bolts and nuts shall conform to the requirements in ASTM Designation: A 307,unless otherwise specified <br /> in the special provisions or shown on the plans. <br /> Anchor cable shall be 19-mm preformed, 6 x 19, wire strand core or independent wire rope core (IWRC), <br /> galvanized in conformance with the requirements in Federal Specification RR-W-41 OD, right regular lay, <br /> manufactured of improved plow steel with a minimum breaking strength of 200 kN. Two certified copies of mill <br /> test reports of each manufactured length of cable used shall be furnished to the Engineer. The overall length of each <br /> cable anchor assembly shall be as shown on the plans,but shall be a minimum of 2 in. <br /> Where shown on the plans, cable clips and a cable thimble shall be used to attach cable to the anchor rod. <br /> Thimbles shall be commercial quality, galvanized steel. Cable clips shall be commercial quality drop forged <br /> galvanized steel. <br /> The swaged fitting shall be machined from hot-rolled bars of steel conforming to AISI Designation: C 1035, <br /> and shall be annealed suitable for cold swaging. The swaged fitting shall be galvanized before swaging. A lock pin <br /> hole to accommodate a 6-mm,plated, spring steel pin shall be drilled through the head of the swage fitting to retain <br /> the stud in proper position. The manufacturer's identifying mark shall be stamped on the body of the swage fitting. <br /> The 25-mm nominal diameter stud shall conform to the requirements in ASTM Designation: A 449 after <br /> galvanizing. Prior to galvanizing,a 10-mm slot for the locking pin shall be milled in the stud end. <br /> The swaged fittings,stud and nut assembly shall develop the specified breaking strength of the cable. <br /> The cable assemblies shall be shipped as a complete unit including stud and nut. <br /> Clevises shall be drop forged galvanized steel and shall develop the specified breaking strength of the cable. <br /> One sample of cable properly fitted with swaged fitting and right hand thread stud at both ends as specified <br /> above, including a clevis when shown on the plans, one meter in total length, shall be furnished the Engineer for <br /> testing. <br /> The portion of the anchor rod to be buried in earth shall be coated with a minimum 0.5-mm thickness of coal tar <br /> enamel conforming to AWWA Standard: C203 or a coal tar epoxy conforming to the requirements in Steel <br /> Structures Painting Council Paint Specification No. 16, Coal-Tar Epoxy-Polymide Black Paint or Corps of <br /> Engineers Specification,Formula C-200a,Coal-Tar Epoxy Paint. <br /> Metal components of the anchor assembly shall be fabricated in conformance with good shop practice and shall <br /> be hot-dip galvanized in conformance with the provisions in Section 75-1.05, "Galvanizing." <br /> Anchor cables shall be tightened after the concrete anchor has cured for at least 5 days. <br /> Concrete used to construct anchors for end anchor assemblies shall be Class 3 or minor concrete conforming to <br /> the provisions in Section 90, "Portland Cement Concrete." <br /> Concrete shall be placed against undisturbed material of the excavated holes for end anchors. The top 300 mm <br /> of holes shall be formed,if required by the Engineer. <br /> Reinforcing steel in concrete anchors for end anchor assemblies shall conform to the provisions in Section 52, <br /> "Reinforcement." <br /> The second paragraph in Section 83-1.02D,"Steel Bridge Railing,"of the Standard Specifications is amended to read: <br /> Structural shapes, tubing,plates,bars,bolts,nuts, and washers shall be structural steel conforming to the provisions <br /> in Section 55-2,"Materials." Other .fittings shall be commercial quality. <br /> The second and third paragraphs in Section 83-1.02E, "Cable Railing," of the Standard Specifications are replaced with <br /> the following paragraph: <br /> Contract No. 10-OM7104 <br /> 57 <br />