Stabttized C mitruc ion Entrance/Exit TC-1 <br /> Crushed aggregate greater than 3 <br /> but smaller than 6". <br /> Filter fabric <br /> I Original <br /> Q oQ grode <br /> 12" Min, unless otherwise <br /> specified by a soils engineer <br /> SECTION B-B <br /> N TS <br /> Crushed aggregategreater than 3" <br /> but smaller than 6". <br /> Corrugated steel panels <br /> Original <br /> 0 0 0 <br /> grade <br /> 12" Min, unless otherwise <br /> specified by a soils engineer Filter fabric <br /> SECTION A—A <br /> NOT TO SCAL <br /> NOTE: <br /> Construct sediment barrier Sediment trapping <br /> and chonnelize runoff to device <br /> sediment trapping device <br /> v� <br /> ��c o <br /> i d steel oriels <br /> o atep <br /> Corrugated g <br /> I A <br /> o� <br /> 10' min or <br /> OfI <br /> as required to <br /> occomodate <br /> a' ° anticipated <br /> n 1 ` traffic, whichever <br /> 01 _ ., o� ( is greater. <br /> Z; <br /> ., <br /> Ln <br /> x` <br /> wr 4' min <br /> l <br /> I / � <br /> i <br /> I <br /> 50' min <br /> or four times the circumference <br /> of the largest construction vehicle tire, <br /> Mauch whichever is greater <br /> Existing PLAN <br /> Grade NTS <br /> 6 of 6 California Stormwater BMP Handbook January 2003 <br /> Construction <br /> www.cabmphandbooks.com <br />