Laserfiche WebLink
SCHEDULE OF SHEETS: <br />SHEET O1 -TITLE / CONSTRUCTI ON NOTES <br />SHEET 02-DETAII(S) /STAMPS/ LEGEND <br />SHEET 03 ID 614G-1 <br />SHEET 04- ID -6146-2 <br />SHEET 05 ID 614G-3 <br />SHEET 06 - ID -6146-4 <br />SHEET 07 - ID -6146-5 <br />SHEET 08 -CTS DETAILS & BILL OF MATERIALS <br />CONTACT INFORMATION: <br />ARE PROJECT MANAGER SPAN TANNER (925) 628-2040 <br />PG&E ENGINEER JUAN ROCHA(925) 8560256 <br />PG&E PIPELINE ENGINEER MIKE BENNETT(559) 349-3861 <br />PROJECT MANAGER (GTS) NICOLE PEPPER (925) 5664582 <br />PROJECT ENGINEER (GTS) SALAH ALIAMAL(925) 588-8504 <br />REFERENCE DOCUMENTS. <br />FORM G: DFM1615 01, MP 1.39-16.29, S GNED 11/17/2021 <br />GENERAL NOTES: <br />1. THISDRAWINGISISSUED FOR PERMIT. REFER TO CONTRACT DOCUMENTATION FOR ADDITIONALCLARITY <br />OF SCOPE OF WORK. <br />2 THIS DRAWING HAS BEEN CREATED BY REVIEW OFTHE AS BUILT DRAWINGS& RECORDS. ACCURACY IS <br />DEPENDENT UPON THE SOURCE DOCUMENTS LISTED IN THE REFERENCE DOCUMENTS. <br />3. UTILITIES SHOWN ON DRAWING ARE APPROXIMATE BASED UPON REVIEW OF PG&E DIA SHEET, DIGS BASIS <br />MEMO, & GIS. CONTRACTOR TO CALL USA TO HAVE LOCATION OF THESE FACILITIES MARKED & POTHOLE <br />TO EXPOSE V ERIFD LOCATION. <br />CONSTRUCTION NOTES: <br />1. UNDERGROUND SERVI CE ALERT: CALL 811(1-80 0 227-260 0) A MINIMUM OF 2 BUSINESS DAYS (NOT <br />INCLUDING INITIAL DAY OF CONTACT) IN ADVANCE FOR THE MARKING OF UNDERGROUND UTILITIES, <br />INCLUDING ALL NON UTILITIES BEFORE YOU DIG, GRADE, OR EXCAVATE. <br />2 UTILITY NOTES: <br />A.DIMENSIONS SHOWN ON THESE DRA WI NGSARE BASED ON THE BEST AVAILABLE INFORMATION FROM <br />SEVERAL SOURCES, & SHALL BE VERIFIED IN THE HELD BY CONSTRUCTION PERSONNEL PRIOR TO <br />EXCAVATION. <br />B. THE INFORMATION SHOWN ON THESE DRAWINGS CON OPENING TYPE & LOCATION OF <br />UNDERGROUND UTILITIES, PROPERTY PINES, & OTHER SUBSTRUCTURES IS NOT GUARANTEED TO BE <br />ACCURATE OR ALLFNCLUSVE, UNLESS OTHERWISE NOTED. CONSTRUCTION PERSONNEL ARE <br />RETONSBLE FOR MAKING ALL DETERMI NATIONSASTO THE TYPE & LOCATION OF UNDERGROUND <br />UTILITIES & OTHER SUBSTRUCTURES AS NECESSARY TO AVOID DAMAGE OR ENCROACHMENTS. <br />C PROSPECTING IS REQUIRED AHEAD OF WORK. <br />D. ALL EXCAVATIONS WITHIN EXISTING STATIONS SHALL BE HAND DUG OR EXCAVATED USING SOFT DIG <br />METHODS (e.g. VACUUM EXCAVATIONS OR SMILER). <br />PACIFIC GAS & ELECTRIC <br />I D -614G <br />DFM1615-01, MP 1.39 - 16.29 <br />ILI INVESTIGATION DIG <br />4I:-11. • . <br />3. COATING REMOVAL: <br />BEFORE REMOVING THE PIPE COATING ON PRE 1972 PIPE (DOES NOT INCLUDE PLASTICTAPE OR FUSION <br />BONDED EPDXY COATINGS) THE FOLLOWING STEPS SHALL BETAKEN <br />AFORALLNON-EMERGENCY WORK, PRE 1972 PIPE WRAP MUST BE EVALUATED TO DETERMINE IF IT <br />CONTAINSASEESTOS PRIOR TO REMOVAL <br />B. FOR EMERGENCY WORK ON PRE 1972 PIPE, ASSUME THE WRAP CONTAINS, 1% ASBESTOS UNTIL THE <br />WRAP CAN BE TESTED. <br />C OBTAIN SAMPLES OF THE WRAP, & HAVE SAMPLES TESTED FOR ASBESTOS IN ACCORDANCE WITH WP <br />4711-01. <br />D.TEST RESULTS ARE TO BE INCLUDED WITH THE FINAL JOB PACKAGE. <br />E. FOLLOW PROCEDURE IN WP 4711-01 FOR REMOVAL OF PIPE WRAP. <br />4. RESTORATION&CLEANUP <br />A.RESTORATI ON OF PUBLIC STREETS SIDEWALKS, CURBS, ETC ABOVE PIPE BEDDING SHALL BE IN <br />ACCORDANCE WITH THE LATEST OTD, COUNTY, OR AGENCY STANDARDS <br />B. WHEREVER THERE ARE ROW CROPS THE TOPSOIL SHALL BE REMOVED TO A DEPTH OF 12 & STORED <br />ONSITE. UPON COMPLETION OF CONSTRUCTION, THE TOPSOIL SHALL BE RESTORED. TAKE CARE TO <br />PREVENT MIXING OF TOPSOIL & SUBSOIL <br />5. WELDING REQUI REMENTS: <br />AJASTALL TEST STATIONS WITH THERMITE WELD CONNECTION IN ACCORDANCE WITH GAS T & D <br />CORROSION CONTROL MANUAL 0-10, 0-10.1, & 0-102 <br />6. PAINTING& COATING REQUIREMENTS: <br />A.ALL EXPOSED PIPE & FITTINGS ARE TO BE PAINTED IN ACCORDANCE WITH GAS STANDARD E-30. ALL <br />COATING ON BURIED PIPE & FITTINGSARE TO BE ALEUT ED IN ACCORDANCE WITH GAS STANDARD <br />E-35. <br />B. FOR COATING SELECTI ONS ON BURIED PIPE, SEE DIRECT BURIALCOATING SELECTIONSTABLE. <br />7. DOCUMENTATION OF INSPECTION OF EXISTING PIPELINE: <br />WHENEVER EXISTING BURIED GASFAOUTIESARE EXCAVATED DURING ENGINEERING OR DURING <br />CONSTRUCTION, AN A FORM (TD 4110P 03 DOE) SHALL BE COMPLETED FOR THE GENERAL INSPECTION. <br />THISALSO APPUESTO GAS FACILITIES BEING DEACTIVATED. THE COMPLETED A FORM SHALL BE <br />SUBMITTED WITH THE FINALJOB PACKAGE. <br />S. COPIESOF REFERENCE DRAWINGSARE AVAILABLE TO HELD PERSONNEL (PG&E, INTECTION OR <br />CONTRACTOR) ON AN AS NEEDED BASS. CONTACT THE PROJECT ENGINEER IDENTIFIED IN CONTAaSTO <br />OBTAIN COPIES OF REFERENCE DRAWINGS. <br />E ... Ion <br />tx IDG14G-165 <br />ID•614G • Z <br />Ripon 0171 Rio <br />Riverta nk <br />ID -614G-364 <br />Sanda <br />MANOR <br />VICINITY MAP DANJOAQUIN& STAMSAUS COUNTIES, CA <br />NOT TO SCALE <br />SEQUENCE OF OPERATIONS. <br />1. INSTALL BMPS <br />2. EXCAVATE & EXPOSE PIPELINE AS SHOWN IN LOCATION IMAGE(S)& IDENTIFIED IN IU DIG <br />SHEET (FORM G), ISFR, AND DIG MAP. <br />3. IF NECESSARY, EXTEND BELLHOLES WITH TRENCHESTO LOCATE REFERENCE GIRTH WELDS <br />ASNOTED IN LOCATION IMAGE(S). <br />4. COMPLETE PIPELINE INSPECTION IN ACCORDANCE WITH LID 4810P-11INLINE <br />INSPECTIONS PROCEDURE. <br />5. COMPLETE "IT" FORM I NSPE CTI ON. <br />6. PERFORM REPAI RS AS N EEDED. <br />7. RECOAT TH E PI PELI N E I N ACCORDAN CE WITH GAS STAN DARD E-35. <br />S. COMPLETE DOCU MENTAL ON AS REQU ESTED BY THE PROJECT ENGI N PER. <br />9. BACKFIILL &COM PA CT EXCAVAL ON PE R PERMIT STAN DARDS <br />10. INSTALL PG&E GAS WARM NG D ECALS& PIPELINE MARKER D ECALS AS N EEDED. <br />11. REMOVE BMPS. <br />12. RESTORE PROJECT SITE. <br />HIS DRAWING Is FOR PACIFIC GAS & ELECTRIC <br />GTS . VISUAL <br />CA REFERENCEOFEXISTING ONLY <br />SCW£ IS APPROXIMATE. SSU E� ID -614G <br />LOCATION RO EXISTING <br />PNDPTURES IS DFM1615-01, MP 1.39 — 1629 <br />STRUCTURES IS g 02/02E22 ISSUED FOR PERMIT 84018702 IEA SFA DJM F�R <br />AlGeinDllfaampary APPreOXIMATEANY ADD IFI INVESTIGATION DIG <br />476 Ewnon Ean,&ib25p ALL DIMENSIONS ARE A 01/13/22 ISSUED FOR REVIEW 84018702 IEA SFA DJM PERMIT <br />minmCmt,GWa Primoris uo.rl SON. nPPRDxI11— Oremlrvu SAN JOAQUIN & STANISIAUS COUNTIES, CALIFORNIA <br />wq.dxa leayrae4aDRAWING SIZE 11%17'. NO. DATE DESCRIPTION 6M/SPEC OWN CHAD SUPV SCALES: SHEET <br />: <br />GOOGLF EARTH REVISIONS As snowN 84018702 J DE a B <br />ARB Underground Ball before You dig. IMAGE SOURCE <br />INCH <br />