My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Permits & Development - Encroachment(EP)/Driveway(DW) Permits - 2022_PS-2203001 thru PS-2203500_ - PS-2203361
PublicWorks
>
- PUBLIC SERVICES
>
PERMITS & DEVELOPMENT
>
Encroachment(EP)/Driveway(DW) Permits
>
2022
>
PS-2203001 thru PS-2203500
>
Permits & Development - Encroachment(EP)/Driveway(DW) Permits - 2022_PS-2203001 thru PS-2203500_ - PS-2203361
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/7/2022 4:28:27 PM
Creation date
11/7/2022 4:24:34 PM
Metadata
Fields
Template:
Permits_Development
DocName
PS-2203361
Category07
Encroachment(EP)/Driveway(DW) Permits
Year2
2022
Notes2
W/S of Fairway Dr. 126' N/O Oakridge Way
Address
PO Box 3031, Modesto,CA 95353
Application
Pacific Gas & Electric-Modesto
Type
Aerial Work
Supplemental fields
Cross Ref
PWP730052
Type (2)
Encroachment Permit (EP)
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
10
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
PT10146-A <br />PT7148-B <br />PT7148-C <br />PT6136-B <br />PT6736-C <br />PT6135-A <br />PT6736-8 <br />PT6735-7 <br />PT7148-6 <br />PT6736-9 <br />PG120305-2 <br />PT1974-1 <br />PT7148-7 <br />PT7148-5 <br />PG170158XT-1 <br />PT12432-23 <br />PT12432-22 <br />3145 <br />3146 <br />2A <br /> TPX <br /> <br />(8 <br />5 <br />' <br />)3-1/0A3-2 <br />C <br />3-1/ <br />0 <br />A <br />3-2 <br />C <br />3-1/0A3-1/0A2A TPX (105') <br />2A T <br />P <br />X <br /> <br />( <br />8 <br />5 <br />' <br />)3-6C 12kV3-6 <br />C <br /> <br />1 <br />2 <br />k <br />V <br />3-6C 12kV3-6C 12kV3-6C 12kV (205')3-6C 12kV3-6C 12kV2-6 <br />C <br /> <br />1 <br />2 <br />k <br />V <br />6A DPX <br />6A DPXD7819 <br />15T <br />D7821 <br />15T <br />D7817 <br />20E <br />69355 <br />5203-3430 <br />50 <br />155185-3398 <br />5202-3452 <br />5198-3396 <br />50 <br />25 <br />5183-3430 <br />50 <br />50' <br />35' <br />50' <br />45' <br />45' <br />40' <br />55'-H1 <br />50' <br />40' <br />40' <br />40' RIVIERA DRCLI <br />F <br />F <br /> <br />D <br />R <br />OA <br />K <br />R <br />I <br />D <br />G <br />E <br /> <br />W <br />A <br />Y <br />FAIRWAY DR-3207- <br />-3137- <br />-4118- <br />-4140- <br />-3307- <br />-3121- <br />-4109- <br />-3333- <br />-4115- <br />-4135--3239- <br />-3107- <br />-4106- <br />-4108- <br />-4124- <br />-3341- <br />-3233- <br />-4117- <br />-4131- <br />-4124- <br />- CITY PERMIT REQUIRED <br />- TCP/FLAGGING REQUIRED <br />CONSTRUCTION NOTES: <br />-CUSTOMER: HAROLD FOWLER <br />-CUSTOMER CONTACT: HAROLD OR MICHELLE FOWLER <br />-CUSTOMER NUMBER: (209)915-5494 <br />APPLICANT: <br />- NO WORK ON LOCATION 1 - FOR REFERENCE ONLY <br />CONSTRUCTION NOTES LOC 2: <br />- REPLACE PRIMARY SLACK SPAN CROSSARM W/ 10-6' <br />XARM DUE TO 4 CUTOUTS NEEDED. ( 2 FOR PRIMARY <br />LINE & 2 FOR TX) <br />- INSTALL 50KVA 120/240 1PH OH TX <br />- INSTALL SEC BREAKERS <br />- INSTALL 1/0A TPX SVC <br />CONSTRUCTION NOTES LOC 1: <br /> INSTALL REMOVE DESCRIPTION <br />LEGEND <br />INSTALL OH TX 1Ø <br />INSTALL SECONDARY BREAKER <br />0010-349650kVA <br />VD= 1.95VVF= 2.06V @ 120A <br />SCI= 10,000A <br />INSTALL SEC BREAKERS <br />INSTALL 1/0A TPX SVC <br />CONSTRUCTION NOTES LOC 3: <br />- INSTALL 200A SMART METERINSTALL SMART METER <br />MOVE METER #'S 1006574574, 1010959722, AND 1005360543 <br />FROM CGC# 317520353430 TO CGC#100000123496. <br />MAPPING NOTES: <br />200A <br />1/0A TPX (4 <br />2' <br />)SSD: SWITCH D19750.20 MILOC 2 <br />NOTE: POLE INSTALLED IN 2018 <br />VD= 3.06VF= 4.82V @ 100AVR = 1.27V <br />VD= 3.9VVF= 4.54V @ 120A <br />2A TPX (105')(117')2 <br />A <br /> <br />T <br />P <br />X <br /> <br />( <br />8 <br />0 <br />' <br />) <br />2-6 <br />C <br /> <br />1 <br />2 <br />k <br />V <br />SL <br />A <br />C <br />K <br /> <br />( <br />5 <br />1 <br />' <br />) <br />VD= 4.95VVF= 6.44V @ 120A <br />EXISTING SEC BREAKERS
The URL can be used to link to this page
Your browser does not support the video tag.