COUNTY OF SAN JOAQUINTRAFFIC CONTROL PLANFRONTAGE RD, APACHE DRMANTECA, CA 95336OF 8JOB ID:DATE: 12/08/202170228-5290536CITY/STATE:MANTECA, CA 95336COMMUNICATIONSABBREVIATIONSBUILDING1UTILITIESwgsstesdPOLESFACILITIESWGSSTSDECENTERLINECONCRETESIDEWALKDRIVEWAYEDGE OF PAVMENTFACE OF CURBHANDHOLEMANHOLEPEDESTALPOLYVINYL CHLORIDESUB DUCTPROPERTY LINERAILROADRAILROAD R/WRIGHT OF WAYSOUTHERN CAL EDISONWALL TO BUILDINGWALL TO POLENOT TO SCALELEGENDCONDUITJTTPROPOSEDBLDGC/LCONCCSWDWYEOPFOCHHMHPEDPVCSDP/LRRRR R/WR/WSCEW-BW-PNTSEXISTINGbldgc/lconccswdwyeopfochhmhpedpvcsdp/lrrrr r/wr/wsceMainline/Backbone Conduit or ABSGasService Lateral ConduitJoint TrenchSole TrenchProposed Construction Call OutExistingProposedWaterTelephoneSan SewerElectricStorm DrainExistingProposedFrontier OwnedForeign OwnedJoint OwnedManholeHandholePullBoxBore Pit5/8" - 8' Copper Ground RodMaterial provided by Frontier & Placed by Developer.Non-Reimbursable Material Provided & Placed by DeveloperSTREET ADDRESS: FRONTAGE RD, APACHE DRPM: TERRANCE LAURYPHONE: (714) 509-0068FTR ENGINEER:TOM PEARSON (805) 437-9351FTR INSPECTOR:THOMAS BOBIAN (209) 305-90771CPFRONTIER COMMUNICATIONCONSTRUCTION SPECIFICATIONS1. Contact Frontier Engineer sixty (60) days prior to need of service in order to confirmcompliance,order materials,and schedule work forces.2. FRONTIER COMMUNICATIONS,INCORPORATED, RESERVES THE RIGHT TO REFUSEANY CONDUIT, PULL BOXES, MANHOLES, OR UTILITY BOXES THAT DEVIATE FROMPLANS AND SPECIFICATIONS.3. CHANGES OR DEVIATIONS FROM THIS PLAN MUST BE APPROVED BY FRONTIER.4. CONTACT THE FRONTIER INSPECTOR 58 HOURS BEFORE TRENCHING AND UPONCOMPLETION OF YOUR SUBSTRUCTURES TO SCHEDULE FINAL INSPECTION.5. FRONTIER INSPECTOR SHALL BE PRESENT ON SITE WHEN THE CONTRACTORNEEDS TO ACCESS ANY EXISTING FRONTIER FACILITY.6. All conduit risers bends to have a minimum thirty-six (36) inch radius.7. All horizontal ninety degree bends (90º) shall have a radius of not less than 12.5 feet and allvertical ninety degree bends (90º) shall have a radius of not less than three feet. No more thantwo (2) ninety (90º) degree horizontal bends shall be placed in any single run unless otherwisespecified. Contact Frontier engineer concerning any required deviations.8. All conduit must be proofed using a mandrel no less than a 1/2" smaller than the conduit to beaccepted. Mule tape shall be placed in all conduits proven. Wall to wall measurements mustbe taken with mule tape.9. Accurate AS-BUILTS shall be provided to the Frontier inspector assigned to this project.AS-BUILTS shall include conduit section measurements, wall to wall footages, stations andoffsets of AS-BUILT Frontier structures, and the cover to the top of the Frontier undergroundstructures placed. Copy of the AS-BUILT conduit work order must be provided to the Frontierinspector assigned to your project.10. Contact the inspection office for coordination of inspection dates.11. Place weatherproof cap on end of all conduits terminated outside of a building.12. Place temporary weatherproof cap on the end of all conduits exposed during construction.13. Rigid steel, approved plastic conduit (OVC Schedule #40, TYPE-C(4") or DB-120 (2") orFrontier provided or approved Roll Sheet sub duct, is specified for underground construction.Condulets, Flex, Transite, Plumbers fittings, Water and Gas Pipes must NOT be used. RIGIGSTEEL MUST BE USED WHEN CONDUIT CAN BE EXPOSED TO VEHICULAR TRAFFIC.14. Conduit terminated on a pole must be PVC Schedule 80. if conduit will be exposed to traffic,rigid steel pipe and sweep is required to 48" above finished grade otherwise turned up 12"above finished grade. Location of riser on pole will be as shown on conduit plan and locationcan be modified by approval of Frontier engineer/inspector only.15. Minimum separation from other utilities shall be minimum of 12". Conduit placed in sametrench with primary power conduit must be separated by no less than twelve inches (12") ofwell-packed sand or three inches (3") of concrete. Minimum cover shall be no less than thirtyinches (30") measured from final grade of the street flow line to the top of Frontier structureunless noted otherwise. Ducts placed in the driven portion of the roadway must have mo lessthan forty eight inches (48") of cover to the top of pipe measured at flow line of roadway.16. FRONTIER RECOMMENDATIONS: Provide a minimum 1-4" conduit home run from eachsuite location to the main terminal backboard in lieu of running cables over drop ceiling access.Frontier will not install cables not contained in conduit.17. Provide source of ground at the telephone backboard location: (1) #6 insulated copper wire(solid preferred) to power system ground. - (1) #6 insulated copper wire (solid preferred) topermanent metallic structure such as UFER ground or building steel. - (1) #6 insulated copperwire (solid preferred) to metallic water pipe bonded to previously described permanent metallicstructure. Leave adequate wire to extend six feet beyond base of backboard. NOTE: THEFOLLOWING MUST NOT BE USED FOR GROUND SOURCES: ROOF TRUSSES, FLOORJOINTS, BRACES, SPRINKLER SYSTEM PIPES, METAL ELECTRICAL DISTRIBUTIONCONDUIT, AND HORIZONTAL STEEL MEMBERS LESS THEN 3/8" THICK.18. Provide cable racking as described in attachment. Provide pulling irons as described inattachment.19. Three to six weeks will be needed from the date of final inspection for Frontier to start placingfacilities. All paperwork and easements must also be completed, if applicable.20. Work crew to adjust manholes to final grade as shown on the approved grading plan.21. Actual footages of conduit are needed to order materials.VICINITY MAPN.T.S.SHEET INDEX:1. COVER2. TRAFFIC CONTROL LEGEND3-8. TRAFFIC CONTROL PLANSCOPE OF WORK:WORK CREW TO PLACE (24442') OF UNDERGROUND, OVERLASH, STRANDCABLE, ACCESS (54) UTILITY POLES, (162) NEW VAULTS AND SET UPCORRESPONDING TRAFFIC CONTROL IN ACCORDANCE WITH CITYSTANDARDS.PROJECT LOCATION