GENERAL NOTES <br />1. ALL WORK SIWl COMPLY WITH APPLICABLE LOCAL AND <br />REGULATORY AGENCIES INCLUDING, BUT NOT LIMBED TO <br />0514A ETC. GENERAL NOTES SHALL APPLY TO ALL DRAWINGS. <br />2. EXISTING UTILITIES ARE SHOWN IN APPROXIMATE <br />LOCATIONS. SOME EXISTING UTILITIES MAY NOT BE <br />DEPICTED ON THIS PLAN. <br />3. IT WILL BE THE RESPONSIBILITY OF THE SUBCONTRACTOR <br />TO MAINTAIN CONSIRUCITON AS -BUILT DATA <br />4. APPROXIMATE LOCATIONS OF MANHOLES, SPLICE <br />BOXES AND HANDHOLE'S ME SHOWN ON THE PIANS. EXACT FINAL <br />LOCATION OF SPLICE BOXES AND HHS SHALL BE DETERMINED IN <br />THE FIELD AFTER ALL EXISTING UTILITIES IN THE AREA OF WORK <br />HAVE BEEN LOCATED. COORDINATE FINAL SPLICE BOX/HH <br />LOCATIONS WAFT PG&E <br />CONSTRUCTION NOTES <br />1. ALL TRAFFIC CONTROL DEVICES SHALL BE IN PLACE <br />BEFORE WORK IS STARTED. DEVICES NO LONGER <br />REQUIRED SHALL BE REMOVED AS SOON AS POSSIBLE <br />2. PEDESTRIAN TRAFFIC MUST BE MAINTAINED AT ALL <br />TIMES. PEDESTRIANS MAY BE RELOCATED ONTO PRIVATE <br />PROPERTY WAFT OWNERS PERMISSION ONLY. <br />3. NO EQUIPMENT OR MATERIALS SHALL BE STORED OR <br />PERMITTED TO STAND UNPROTECTED WHERE TRAFFIC IS <br />MAINTAINED UNLESS IT IS ALLOWED BY LOCAL JURISDICTION <br />IN WRITING. <br />4. NO EQUIPMENT OR MATERIALS SHALL BE STORED ON <br />ROAD SURFACE DURING NON -WORKING PERIODS UNLESS <br />IT IS ALLOWED BY LOCAL JURISDICTION IN WRITING. <br />5. NO EQUIPMENT OR MATERIALS SHALL BE STORED ON <br />SIDEWALK UNLESS IT IS ALLOWED BY LOCAL JURISDICTION <br />B. EXCAVATION MATERIAL SHALL BE STORED AWAY FROM <br />THE PAVED ROADWAY WHENEVER POSSIBLE ALL SPILLED <br />MATERIAL IS TO BE REMOVED TO AVOID SLIPPERY <br />CONDITIONS. <br />7. EXISTING SIGNS, DELINEATIONS. GUARDRAILS, MARKERS, <br />TREES, SHRUBS. FENCES. WALKS. STEPS. ETC. THAT ME <br />DISTURBED BY THIS CONSTRUCTION SHALL BE REPLACED <br />OR RESTORED TO THEIR ORIGINAL CONDITION. <br />& CONTRACTOR SHALL VERIFY EXACT LOCATION AND <br />ELEVATION OF ALL EXISTING UTILITIES IN AREA OF <br />WORK PRIOR TO CONSTRUCTION. CALL UNDERGROUND <br />SERVICE ALERT (CAUFORNIA, 1-800-227-2900) AT LEAST <br />48 HRS PRIOR TO START OF CONSTRICTION ACTIVITIES. <br />9. CONTRACTOR SHALL HAND DIG AND USE EXTREME CARE <br />WHEN WORKING IN CLOSE PROXIMITY TO EXISTING <br />UTILITIES. CONTRACTOR MUST POM40 E & EXPOSE EXISTING <br />UTILITIES WHEN NEW CONSTRUCTION CROSSES IT. <br />10. TRAFFIC SIGNAL DETECTOR LOOP CIRCUITS ARE NOT <br />SHOWN. CONTRACTOR SHALL LOCATE ALL TRAFFIC <br />SIGNAL DETECTOR LOOP CIRCUITS PRIOR TO ANY <br />TRENCHING OR BORING. ALL TRAFFIC LOOP DETECTOR <br />CIRCUITS SHALL BE MAINTAINED AND PROTECTED. <br />NOTIFY TRAFFIC DEPARTMENT 45 HOURS PRIOR TO <br />ANY WORK IN THESE AREAE. <br />11. THE REMOVAL, STORAGE, AND REPLACEMENT OF ALL <br />SHRUBBERY WILL BE THE RESPONSIBILITY OF THE <br />CONTRACTOR OR SUBCONTRACTOR. <br />12. CONTRACTOR IS RESPONSIBLE TO ARRANGE A PRE - <br />CONSTRUCTION MEETING WITH THE CITY INSPECTORS <br />AT LEAST 72 HOURS BEFORE STARTING WORK. <br />13. BORING PITS- EXCAVATION AND RESTORATION OF BORING <br />cwwi BE IN ACCORDANCE WITH THE CRY/COUNTY STANDARDS <br />FOR UTILITY EXCAVATIONS AND LOCATED TO THE SATISFACTION <br />OF THE CITY/COUNTY ENGINEER. <br />14. MAINTAIN 12' SEPARATION FROM PRIVATE UTILITIES. MAINTAIN 5' <br />SEPARATION FROM WATER, SEWER AND STORM DRAIN. <br />15. DEPTHS OF EXISTING UTILITIES NOT REQUIRED OR AVAILABLE <br />LIGHT VERTICAL LINES SHOWN IN PROFILES INDICATE APPROXIMATE <br />UTILITY LOCATION ALONG THE DUCT. THE CONTRACTOR SHALL <br />POTHOLE TO CONFIRM EACH DEPTH. <br />SAFETY <br />1. THE CONTRACTOR IS RESPONSIBLE FOR JOB -SITE SAFETY AND SHALL <br />BE RESPONSIBLE FOR ALL LIABILITY IMPOSED BY LAW FOR PERSONAL <br />INJURY OR PROPERTY DAMAGE WHICH MAY MISE OUT OF THE WORK <br />PERFORMED UNDER THE ENCROACHMENT PERMIT. OR WHICH MAY ARISE <br />OUT OF THE SAFETY FAILURE ON THE PART OF THE PERMITTEE TO <br />PERFORM HIS OBLIGATIONS UNDER THIS PERMIT IN RESPECT TO <br />MAINTENANCE OF THE ENCROACHMENT. <br />2. ALL TRAFFIC CONTROL SHALL CONFORM TO THE CURRENT CALIFORNIA <br />DEPARTMENT OF TRANSPORTATION ('MANUAL OF TRAFFIC CONTROLS <br />FOR CONSTRUCTION AND MAINTENANCE WORK ZONE-) ('MANUAL OF <br />WARNING SIGNS. LIGHTS AND DEVICES FOR USE IN PERFORMANCE OF <br />WORK UPON HIGHWAYS'). <br />3. ALL EXCAVATIONS SHALL CONFORM TO THE REQUIREMENTS OF THE <br />STATE OF CALIFORNIA DIVISION OF OCCUPATIONAL SAFETY AND <br />HEALTH. THE PERMITTEE MAY BE REQUIRED TO OBTAIN A 'PERMIT TO <br />EXCAVATE' FROM THE DIVISION OF INDUSTRIAL SAFETY. DEPARTMENT <br />OF INDUSTRIAL RELATIONS. STATE OF CALIFORNIA <br />4. CONTRACTOR SHALL FURNISH AND MAINTAIN ALL DEVICES FOR <br />PEDESTRIAN AND VEHICULAR TRAFFIC SAFETY. UNSAFE CONDITIONS <br />WILL BE CORRECTED BY CITY PERSONNEL (OR AGENTS THEREOF) AND <br />THE PERMITTEE WILL BE BILLED FOR ALL EXPENSES INCURRED. OR <br />COSTS SHALL BE RECOVERED FROM CASH DEPOSITS HELD FOR SUCH <br />PURPOSES. <br />PROJECT CONTACTS <br />CNIEL INC Mykwwft CmwW6eM) <br />PAUL NIASNALL OFFICE: (918) 881-2220 <br />CML ENGINEER MOBILE• (510) 703-0871 <br />3501 SUNRISE BLVD.. SIE 15 <br />RANCHO COFIDOVA, CA 95742 EMAIL. pmudwlOcMel.com <br />EMAIL. 53GNOppa.wm <br />MOBLE (510) 230-3572 <br />USA (Coil bdaa you dto corks alit) <br />OFFX E- (800) 227-200 <br />ABBREVIATIONS <br />PLANT OF ENTRY <br />AL COMMUNICATION NETWORK <br />ED CONCRETE PIPE <br />WAY <br />U <br />MAIN <br />RAPRICS INC. <br />GAIT <br />SERER CLEANOUT <br />E <br />E GAS ELECTRIC <br />NNAL <br />CLAY PIPE <br />LEGEND <br />—IRIE— <br />NEW POM FIBER AND CONDUIT <br />MCI— <br />DOW IRI COMIN <br />---Pw--- <br />NEW PAW FIBER N EX CCWMAT <br />RIFs <br />Dow IIS COAVAT <br />PGE <br />EXISTING PG&E CONDUIT <br />sPT <br />Dow SPRINT OOMLN <br />c <br />Dow LOAM m <br />PWT— <br />EXISM OKST COMLN <br />G <br />WING FGRE MIRWN. GAS <br />c <br />DOW COLIBU/(S) <br />N? <br />DISIM M PTOOICIS NITROGEN WN <br />c <br />MING PIT£ NATURAL GAS <br />ss <br />E1161NG S4M WT SENER <br />N2— <br />onZI1G M FROM1715 NITROGEN MAN <br />SD <br />Dam S7UM UIWN <br />ss- <br />OEM S'IMW SETTER <br />RGw <br />E105I1INC IEUAMM MER <br />so <br />onflNG STORI1 am <br />w <br />E dsm IIRXER <br />Rcw <br />DEW IEUAI ED RNER <br />F <br />on= E BCW <br />w <br />E1f6w VAIM <br />r <br />EXISING IEIEPMIE <br />E <br />asTwo ELECTRIC <br />o <br />OgS'IW/NI.AII IHeMIOLE <br />J7 <br />Elmm JON TERCH <br />v <br />r <br />EIBTPP TEUNIOE <br />s <br />A'SSIGMS? OLNIBLR <br />FO <br />OEM SEER OPTIC LIE <br />w <br />DSIANCE FROM SPLICE TDA' <br />ID SPLICE 90X <br />CN <br />EXSI►IB COLE N <br />CLE <br />DEWDEWFIRE <br />Eu <br />E dm EEI avaur <br />� <br />EX611IB RTE HHDLMW/ <br />IRTER LITH: <br />07S <br />TRAFFIC am <br />? <br />LINT POLE <br />• <br />DIST. TEE <br />WDER WI IE <br />® <br />PROPETRY ADDRESS <br />• <br />NOW POLE <br />DEPN 10 TWIT <br />SD ow OFESS/ � <br />(.l POTHOLE (raaC4 <br />PM RVIMNG IM. C 46732 <br />