Permits & Development - Encroachment(EP)/Driveway(DW) Permits - 2021_PS-2101001 thru PS-2101500_ - PS-2101157
PublicWorks
>
- PUBLIC SERVICES
>
PERMITS & DEVELOPMENT
>
Encroachment(EP)/Driveway(DW) Permits
>
2021
>
PS-2101001 thru PS-2101500
>
Permits & Development - Encroachment(EP)/Driveway(DW) Permits - 2021_PS-2101001 thru PS-2101500_ - PS-2101157
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/6/2023 3:22:50 PM
Creation date
1/6/2023 3:18:14 PM
Metadata
Fields
Template:
Permits_Development
DocName
PS-2101157
Category07
Encroachment(EP)/Driveway(DW) Permits
Year2
2021
Notes2
S/S of Woodbridge Rd. 14,950' W/O Thornton Rd.
Address
PO Box 930, Stockton,CA 95201
Application
Pacific Gas & Electric-Stockton
Type
Traffic Control Devices
Supplemental fields
Cross Ref
PWP730052
Type (2)
Encroachment Permit (EP)
Callout
ID:
1
Creator:
Created:
1/6/2023 3:18 PM
Modified:
1/6/2023 3:18 PM
Text:
UCCo to begin HDD at this location.
ID:
2
Creator:
Created:
1/6/2023 3:18 PM
Modified:
1/6/2023 3:18 PM
Text:
UCCo proposed 1" PL location.1
Text box
ID:
1
Creator:
Created:
1/6/2023 3:18 PM
Modified:
1/6/2023 3:18 PM
Text:
Due to the existing drainage swale, UCCo's equipment will need to park in close proximity to the E/P, thus requiring a 1-lane closure traffic control plan.
Line
ID:
1
Creator:
Created:
1/6/2023 3:18 PM
Modified:
1/6/2023 3:18 PM
Polygon
ID:
1
Creator:
Created:
1/6/2023 3:18 PM
Modified:
1/6/2023 3:18 PM
ID:
2
Creator:
Created:
1/6/2023 3:18 PM
Modified:
1/6/2023 3:18 PM
ID:
3
Creator:
Created:
1/6/2023 3:18 PM
Modified:
1/6/2023 3:18 PM
Rectangle
ID:
1
Creator:
Created:
1/6/2023 3:18 PM
Modified:
1/6/2023 3:18 PM
ID:
2
Creator:
Created:
1/6/2023 3:18 PM
Modified:
1/6/2023 3:18 PM
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
9
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
W WOODBRIDGE RD (60')R11154 <br />PRIVATE DR <br />PRIVATE DR <br />11666 IRRIGATION DITCHEX. 1/2" PL (JT)EX.1/2" PL (JT)EX. 12" TP STL-15' EX. 16" TP STL-15' RR5'20'32'192'165'190'92'DETAIL4SHT 3DETAIL11" PL <br />1" PLMREX. 3/4" STL3/4" STL TPL-196B (PM196163-'92)L-196A (PM61290-'41)5'15'EX. ODORIZERTO BE REMOVED60'24'14,950' FROM THORNTON RDPLAN VIEW% SMYS @ MAOP: %PRESENT MAOP: PSIGPIPE SPECS:HEADER SIZE:YEAR:EXISTING PIPE SPECSA)B)MAXIMUM ALLOWABLE PRESSUREDURING WELDING (G.S.&S. D-22)WHEN WELDING WITHIN 3"EVALUATE THE FOLLOWING OPERATING PRESSURELIMITATIONS TO DETERMINE THE MAXIMUMOPERATING PRESSURE PERMITTED DURING WELDINGOF THE LONGITUDINAL SEAM (EXCEPT DSAWPIPE),THE CIRCUMFERENTIAL, AND ANY BRANCHWELD, OR WITHIN 3" OF ANY DEFECT (GOUGES,CORROSION, LAMINATIONS, ETC.) IN THE PIPEWHICH EXCEEDS 1/3 OF THE NOMINAL WALLTHICKNESS IN DEPTH AND/OR 1/4 OF THE NOMINALPIPE DIAMETER IN LENGTH.WHEN WELDING ON BODY OF THE PIPE.UNLESS,INSTALL JN:WALL THICKNESS:12.750"0.259"API-5L, GR B, SMLS80056.26612901941652 PSIG284 PSIGEXISTING INLET PIPE SPECIFICATIONS:GAS CREW TO SUPPLY CUT OFF SPECIFICATIONSTRANSMISSION LINENEW 3/4" STL PIPETP ROUTE#TIE-IN DETAIL (1" TEE)ADDRESS# & STREET NAMEMAOP ,CONFIRM: SIZE OF TEE ____________________ TYPE OF TEE VALVE TEE (PIN-OFF) SERVICE TEE EXISTING A-105 STEEL CAP (1440 PSIG) YES NO* REPLACE CAST IRON W/ STEEL CAP YES NO N/A POSITION OF TEE ON PIPELINE 12:00 2:00 _______ STUB ORIENTATION PARALLEL TO PIPELINE PERPENDICULAR TO PIPELINE RETRACT STEM OR SHUT-OFF TOOL AFTER C/O. YES INSTALL EMS MARKER BALL AT END OF STUB YES * CONTACT SENIOR GAS DISTRIBUTION ENGINEER IF EXISTINGTEE IS PRE-1962 AND HAS A CAST IRON CAP.TIE IN TO EXISTINGVALVE TEEINSTALLATION JOB# FOR INLET PIPEJOB NUMBERMAOP ESTABLISHED BY STPRINSTALLATION JOB# FOR TEEINSTALLATION JOB# FOR MAINLINEEXISTING1" TEENO STPR TO VERIFY PIPE TESTCUT OFF AT TEE:1. STOP-OFF TEE; CUT OFF EXISTING PIPE AT WELD INTERFACE WITH TEE.2. GRIND BACK 3/16" ON TEE TO REMOVE HEAT AFFECTED ZONE.3. REMOVE EXISTING STEEL RING FROM INSIDE THE OUTLET OF THE TEE, IFAPPLICABLE.4. INSTALL NEW TESTED PIPE.FUTURE DP- YEARJOB NUMBER- YEARJOB NUMBER- YEARMAINLINE PIPELINE HYDROTESTED ONJOB NUMBEROR- YEARMAINLINE TO BE HYDROTESTED/REPLACEDBY PSEP IN YEARMILEPOINT OR GPS COORDINATES GAS FLOW TERMINATED BY:PIPELINETIE IN DETAILUTILIZING EX. TAPPING TEE(TYPICAL)N.T.S.11154 & 11666 WOODBRIDGE RDGRB, SMLS800800169701977NA 197716970612901941 2Z(1"=30')90'60'30'0'NOT ALL PIPE FEATURES TO SCALEPACIFIC GAS AND ELECTRIC COMPANY <br />PLNR: <br />ADE: <br />EST: <br />REP: <br />SUPV: <br />SCALE:DATE:PHONE #:FAX #:PM: <br />NOTIF.:SD:CO: <br />SHT:Other: <br />REV.SHEETS <br />SUPVNO.DATE DESCRIPTION <br />R E V I S I O N S <br />ORDER #DWNCHKD APVD BY <br />0 INCH 165432INCH10A BCDE12345678910925-328-5967 925-244-3303 <br />106231579 <br />OF 3 <br />30953631 1 <br />JOHANNA ANDERSON <br />GERALD GABRIEL <br />11-1-2017 <br />30953631 DNG JMA MD JQISSUED FOR CONSTRUCTION11-1-20171 <br />HPR REPLACEMENT11154 WOODBRIDGE ROADLODI, CA <br />MOLLY BURTON <br />AARON YU <br />DAVE RAYMERS 2 <br />AS SHOWNCOPYPE SIGNATURE STAMP & SIGN17094-078STRENGTH TEST PRESSURETEST MEDIUMPIPE SPEC.O.D.W.T.DESIGN FACTORFDP PSIG % SMYSMAOP PSIG % SMYSMAX.MIN. PSIGPSIG% SMYS% SMYSPSIG=90% SMYSDESIGN CRITERIABOM ITEM # JOB #CLASS LOCATION309536311063.508005.198005.1912007.7814009.0813884API 5L, GR B, SMLSNITROGEN0.540"0.119"FINISH GRADEDETAIL SEE HPR1001011001021031001021081101111091071061051043/4" STLINLET PIPING DETAIL(TYPICAL)(N.T.S)DETAIL 2 & 3EX 12" TP MAIN13'20' MIN42"6"TIEDTIEDTIEDTIEDP/LP/LP/LP/LE/PE/PE/PE/PE/PE/PE/PTOP OFTRANSMISSION MAINCLEX. 1" MUELLER H-17656VALVE TEE (SEE GS&SC-11)VERIFY A105 STEEL CAP(1440 PSIG) IS INSTALLEDAND/OR INSTALL CAP.45°NEW 34" STEELTRANSMISSION MAIN1" MUELLER H-17656VALVE TEE (SEE GS&SC-11) EX VALVE TEETO GAS REGULATION 20' MIN DISTANCEPG&EGAS VALVE(N.T.S)(TYPICAL)EXISTING VALVE TEE INSTALLATION101SEE GS&S A-43 & TIE-IN DETAIL FOR FURTHER DETAILS12" MIN18" MIN1003~Pre 1972 Pipe Wrap Asbestos Stamp(TD-4711P-01)1. Estimating to Complete:Year Pipe Installed:Historical Results, Contains Asbestos?Yes NoUnknownPre 1972 AND Unknown - Sample is Required2. Field (Sampler) to Complete: LAN ID3. Mapping to Complete: LAN IDDate Sampled:Sample ID:Asbestos Result:Yes% ORNo (ND)1941XSTRENGTH TEST PRESSURETEST MEDIUMPIPE SPEC.O.D.W.T.DESIGN FACTORFDP PSIG % SMYSMAOP PSIG % SMYSMAX.MIN. PSIGPSIG% SMYS% SMYSPSIG=90% SMYSDESIGN CRITERIABOM ITEM # JOB #CLASS LOCATION309536311003.508007.798007.791200 11.691400 13.649240API 5L, GR B, SMLSNITROGEN1.050"0.154"E/P
The URL can be used to link to this page
Your browser does not support the video tag.