<br />WORK LOCATION
<br />(INSTALL) b
<br />s
<br />WORK SUMMARY
<br />2 3 4 5 6 7 8 9
<br />VICINITY MAP GRP GB 48 4 4 E, V 0 ADA �I\, VO ADA
<br />ALHAMBRA AVE S/0 E MORADA LN
<br />STOCKTON, CA
<br />1. INSTALL NEW 200' DWA-ND ON ALHAMBRA AVE S/0 E MORADA LN.
<br />2. INSTALL (2) NEW CATHODE LEADS TO 2" STL GAS MAIN
<br />3. INSTALL 10AMP/20V ORNAMENTAL RECTIFIER CABINET
<br />4. ANODE JUNCTION BOX INTEGRATED IN CABINET
<br />5. WATCHDOG REMOTE MONITORING UNIT INTEGRATED WITH CABINET.
<br />6. INSTALL PROTECTION POSTS IN FRONT OF CABINET ON STREET SIDE.
<br />7. INSTALL (2) NEW GROUND RODS IN G-5 BOXES
<br />8. INSTALL NEW 240V ELECTRIC SERVICE FROM SAP POLE ID 102126040 TO
<br />ORNAMENTAL ENCLOSURE.
<br />9. THE ELECTRIC NOTIFICATION 119619642 WAS CREATED FOR THE NEW
<br />UNDERGROUND ELECTRIC SERVICE.
<br />10. SAN JOAQUIN COUNTY WELL PERMIT REQUIRED
<br />11. DESTROY EXISTING DEEP WELL ANODE BED LOCATED AT 4844 E MORADA LN,
<br />MORADA PER COUNTY REQUIREMENTS. REMOVE ALL EXISTING CP EQUIPMENT OFF
<br />SAP POLE ID 102125764 AT 4844 E MORADA LN AND PROVIDE TO THE
<br />CCORROSION MECHANIC.
<br />WORK LOCATION
<br />(DEACTIVATED)
<br />LOCAL CONTACT INFO:
<br />NAME
<br />TITLE
<br />CELL PHONE
<br />BILL BELASKI
<br />CORROSION MECHANIC
<br />(209) 406-7844
<br />DAVID DURHAM
<br />CORROSION SUPERVISOR
<br />(925) 383-6468
<br />RYAN WOOD
<br />CORROSION SPECIALIST
<br />(925) 285-7838
<br />JESSE LEE
<br />SENIOR DISTRIBUTION ENGINEER
<br />(650) 773-9234
<br />ZACHARY PARTIN
<br />DISTRIBUTION ENGINEER
<br />(628) 219-8136
<br />DAVE RYMERS
<br />PLANNING ENGINEER
<br />(209) 406-7782
<br />CARLOS OLGUIN
<br />ESTIMATOR
<br />(707) 308-6195
<br />CHRIS LARUE
<br />ADE
<br />(209) 942-1565
<br />TBA
<br />WORKING FOREMAN A
<br />TBA
<br />TBA
<br />GC FIELD ENGINEER
<br />TBA
<br />GAS NOTES
<br />1. PRIOR TO STARTING WORK, CONTACT LOCAL AREA CORROSION SUPERVISOR REGARDING CATHODIC PROTECTION REQUIREMENTS AND I&R SUPERVISOR REGARDING ANY SHUTDOWN, ABANDONMENT,
<br />OR TIE-IN OF ANY MAINS WHICH MAY AFFECT ANY DISTRICT REGULATOR STATION.
<br />2. ALL STEEL TIE-INS, CUT OFFS AND CAPPING OF CAST IRON AND STEEL MAIN PER A-36 AND C-37.
<br />3. ALL PLASTIC CONNECTIONS TO BE PERFORMED IN ACCORDANCE WITH THE APPROPRIATE PROCEDURES LISTED IN TD -4170S.
<br />4. UNLESS OTHERWISE NOTED, CONSTRUCTION TO REFERENCE TD -4125P-09 TO DETERMINE EXISTING STEEL PIPE SPECS.
<br />5. ALL ARC WELDING IS TO BE PERFORMED IN ACCORDANCE WITH THE GAS WELDING CONTROL MANUAL TD -4160M. REFER TO TD-416OP-20 FOR GENERAL WELDING REQUIREMENTS.
<br />6. PURGE MAINS 10" IN DIAMETER & LESS PER GS&S A-38, ATTACHMENT A, PROCEDURE 2. PURGE MAINS GREATER THAN 10" IN DIAMETER PER GS&S A-38, ATTACHMENT A, PROCEDURE 3.
<br />7. ABANDON ALL UNDERGROUND GAS FACILITIES PER UTILITY PROCEDURE TD-950OP-16 & GS&S A-93.2.
<br />8. PLACE ELECTRONIC MARKING SYSTEM (EMS) DEVICES ON ALL CUT OFF ENDS AND SECTIONALIZING POINTS OF DEACTIVATED PIPE PER TD-950OP-16.
<br />9. FOLLOW ALL MINIMUM INSTALLATION DEPTHS FOR TRANSMISSION, DISTRIBUTION AND SERVICE PIPE BY CLASS LOCATION AND SOIL TYPES OUTLINED IN GS&S A-04.
<br />10. ALL GAS RISERS ARE TO BE INSTALLED IN ACCORDANCE WITH GS&S J-15 & J-15.1.
<br />11. INSTALL METER PROTECTION PER GS&S J-95.
<br />12. VENT REGULATORS PER GS&S H-93.
<br />13. LOCATION OF EXISTING UTILITIES ARE APPROXIMATE. CALL UNDERGROUND SERVICES ALERT (USA) TO CONFIRM. GAS PIPELINES MUST BE INSTALLED WITH AT LEAST 3' OF SEPARATION (5'
<br />PREFERRED) ON ANY PARALLELED INSTALLATION FROM ANY WET UTILITY AND 12" MINIMUM FROM ANY PERPENDICULAR CROSSING PER U.O. STANDARD S5453.
<br />14. CONSTRUCTION SHALL NOTIFY MAPPING WITHIN 24 HOURS OF ALL OPERATIONAL CHANGES TO MAINS, INCLUDING EVERY TIE-IN, CUT OFF, UPRATE, ETC. PER U.O. STANDARD S4412.
<br />15. ALL STEEL RISERS ARE TO BE REPLACED WITH NON CORRODIBLE RISERS OR REPLACED BY USING THE RISER INSERT RENEWAL INSTALLATION PER GS&S A-90.
<br />16. ALL SERVICES AND MAINS TO BE TESTED PRIOR TO TIE-IN PER GS&S A-34.
<br />17. INSTALL PLASTIC MAIN, SERVICES, & LOCATING WIRE PER GS&S A-34, A-90, A-90.2, A-90.3, A-91, A-93, A-93.1, A-93.3, UTILITY STANDARD TD -4170S, D-34 & CORROSION CONTROL
<br />STANDARD TD -4181S.
<br />18. INSTALL ANODES PER CORROSION CONTROL MANUAL 0-13.1.
<br />19. INSTALL ELECTROLYSIS TEST STATIONS PER CORROSION CONTROL MANUAL 0-10 AND 0-10.1. IF PRACTICAL, INSTALL ETS STATION OUT OF THE ROADWAY.
<br />20. ALL EXCAVATION TO BE PERFORMED PER TD -5811M, TD -5811P-301, TD -5811P-105, TD -4412P-05, AND TD -4621S. STANDBY REQUIRED IF EXCAVATING WITHIN 5' OFA CRITICAL FACILITY,
<br />BORING ACTIVITY THAT CROSSES OR THAT PARALLELS WITHIN 10' OF A CRITICAL FACILITY. CONTACT THE CONSTRUCTION SUPERVISOR.
<br />21. NOTIFY SCHOOLS AND HOSPITALS WITHIN 500' OF PROPOSED EXCAVATION FOR GAS FACILITIES A MINIMUM OF 3 DAYS PRIOR TO DIGGING PER AB 1937.
<br />22. ANY PIPE REPLACEMENT VIA SPLITTING TO BE DONE PER TD -4634P-01 & TD -4634P-02.
<br />23. CAMERA INSPECTION (PRE/POST) FOR TRENCHLESS METHODS TO BE PERFORMED PER TD -4632P-01.
<br />24. WARNING TAPE IS TO BE INSTALLED IN OPEN TRENCH INSTALLATION OVER GAS PIPELINES IN BOTH TRANSMISSION AND DISTRIBUTION FACILITIES. THIS INCLUDES BELL HOLES, EXCAVATIONS FOR
<br />REPAIR PURPOSES AND RISER REPLACEMENTS PER GS&S L-16.
<br />25. DEVIATIONS FROM THIS APPROVED DESIGN SHALL BE PROCESSED IN ACCORDANCE WITH TD -4014P-05 "FIELD DESIGN CHANGE PROCESS FOR DISTRIBUTION LINES AND DUAL -ASSET FACILITIES."
<br />26. ALL TRENCH SPOILS AND BACKFILL MUST BE USED OR DISPOSED WITH AS REQUIRED BY PG&E SPECIFICATIONS AND ANY LOCAL CITY, COUNTY OR STATE REQUIREMENTS.
<br />27. PG&E TO INSTALL/RESTORE TEMPORARY AND/OR PERMANENT PAVING IN ACCORDANCE WITH PG&E SPECIFICATIONS AND ANY LOCAL CITY, COUNTY OR STATE REQUIREMENTS.
<br />28. STAND-BY REQUIREMENTS MUST BE IN ACCORDANCE WITH TD -5811P-301, TD -5811P-105 & TD -581113-005 WITH WORKING NEAR ANY CRITICAL FACILITIES.
<br />29. MONUMENT PRESERVATION AS REQUIRED BY THE PROFESSIONAL LAND SURVEYORS' ACT (BUSINESS AND PROFESSION CODE SUB -SECTION 8700-8805) SECTION 8771; PRIOR TO THE START OF
<br />CONSTRUCTION, ALL SURVEY MONUMENTS, WITHIN THE PROJECT LIMITS THAT HAVE THE POSSIBILITY OF BEING DAMAGED OR DESTROYED DURING CONSTRUCTION, MUST BE LOCATED, AND
<br />REFERENCED BY A LICENSED LAND SURVEYOR, AND A CORNER OF RECORD OR RECORD OF SURVEY SHALL BE FILED WITH THE COUNTY SURVEYOR. IF ANY OF THESE SURVEY MONUMENTS ARE
<br />DESTROYED, DAMAGED OR COVERED OVER DURING CONSTRUCTION, A NEW MONUMENT AND MONUMENT BOX MUST THEN BE SET IN ITS PLACE, AT THE ORIGINAL LOCATION, BY A LICENSED
<br />LAND SURVEYOR, AND ANOTHER CORNER OF RECORD OR RECORD OF SURVEY FILED WITH THE COUNTY SURVEYOR.
<br />30. CONSTRUCTION MEANS AND METHODS MAY DEVIATE PER FIELD VERIFIED CONDITIONS IN ACCORDANCE WITH LOCAL JURISDICTION REQUIREMENTS. IF THERE ARE ANY QUESTIONS, CONTACT
<br />RESPONSIBLE ENGINEER.
<br />INSTALL
<br />Cn
<br />Cn
<br />w
<br />9265
<br />LO
<br />LO
<br />N
<br />EX 3/4" STL
<br />EX 1/2" PL SVC
<br />50'
<br />TO E MORADA LN
<br />N
<br />"
<br />= r
<br />v �
<br />2'
<br />- r t-
<br />16'
<br />10'
<br />LON
<br />1 _ �
<br />O
<br />C)
<br />o =
<br />n �
<br />>
<br />x
<br />r
<br />rC X
<br />N
<br />CD
<br />� s
<br />r
<br />1 r- /1 r- A l rl
<br />EXISTING GAS MAIN (SIZE NOTED)
<br />0
<br />C)
<br />r
<br />8
<br />2'
<br />5'
<br />c,;l
<br />M
<br />a
<br />r
<br />f"1
<br />0
<br />z
<br />n
<br />0
<br />PLAN VIEW
<br />N.T.S
<br />DEACTIVATE
<br />w
<br />W
<br />9615in
<br />Fig
<br />F/C
<br />E. MORADA LN
<br />�--- 53'
<br />(T)� HP ' HP
<br />HP HP HP HP EX 3�
<br />ow
<br />r FOG go, FOG
<br />5'
<br />_ E/P E/P
<br />27'
<br />NOTIFIED U.S.A.
<br />DATE:
<br />ncKn g
<br />BY.
<br />35'
<br />I
<br />HP (T)
<br />N.T.S
<br />10
<br />LO
<br />U")
<br />CO
<br />U')U')N
<br />r-
<br />M
<br />00
<br />O
<br />CO
<br />000
<br />M
<br />�
<br />CATHODIC PROTECTION IN WORK AREA
<br />00U')
<br />00
<br />CO
<br />O
<br />- - - - - -
<br />- ANODE WIRES (INSTALL)
<br />rn
<br />ATTENTION FOREMAN:
<br />NCD
<br />O
<br />N
<br />CO
<br />O
<br />O
<br />O
<br />N
<br />O
<br />O
<br />N
<br />l l
<br />r`
<br />N
<br />r`
<br />rn
<br />N
<br />R
<br />0
<br />(925) 285-7838, 48 HOURS PRIOR TO
<br />EXISTING SERVICE
<br />START OF WORK.
<br />Q
<br />W
<br />N
<br />p
<br />=
<br />N
<br />O
<br />J
<br />CD
<br />Q
<br />FOREMAN
<br />PROPERTY LINE
<br />Z
<br />j
<br />p
<br />C
<br />o
<br />M
<br />z
<br />N
<br />Uj 3
<br />M
<br />o
<br />CORROSION MECHANIC FOR LOCATING WIRE
<br />C)
<br />Z
<br />3
<br />o
<br />N
<br />LnnL1
<br />/�
<br />-� J
<br />FOG LINE
<br />INSTALLATION AND CATHODIC PROTECTION
<br />U
<br />U
<br />=
<br />Q
<br />l�
<br />c~n
<br />c
<br />2
<br />w
<br />3
<br />0
<br />z
<br />W
<br />Q
<br />N
<br />0_
<br />Z
<br />a -
<br />•.
<br />z
<br />�
<br />QQ
<br />- - - - - -
<br />- CATHODE WIRES (EXISTING)
<br />w
<br />Installation Tested or Inspected
<br />cw
<br />G
<br />'•
<br />O
<br />F__
<br />w
<br />z
<br />U
<br />CCD
<br />p
<br />and Noted on Drawing.
<br />•
<br />Q
<br />m
<br />o
<br />0
<br />0
<br />DEEP WELL ANODE (INSTALL)
<br />cJ-)
<br />w
<br />CD
<br />w
<br />O
<br />�a
<br />a)
<br />V)
<br />C n
<br />Q:f
<br />3 �
<br />0
<br />U
<br />U
<br />otcc
<br />Q
<br />�
<br />O
<br />w
<br />>
<br />o
<br />Lo
<br />z
<br />crCD
<br />i C-)
<br />C -D
<br />r�
<br />0
<br />¢
<br />¢
<br />�'
<br />11,91
<br />GROUND ROD (INSTALL)
<br />U
<br />�
<br />Li
<br />CL-
<br />U
<br />0
<br />DEEP WELL ANODE (EXISTING)
<br />QCD
<br />CITY: STOCKTON
<br />U
<br />�
<br />=
<br />0
<br />2
<br />N
<br />0
<br />Y
<br />U
<br />3
<br />0
<br />W
<br />v
<br />0
<br />0
<br />0
<br />M
<br />- - - - - -
<br />- GROUND WIRES (INSTALL)
<br />CATHODIC PROTECTION IN WORK AREA
<br />- - - - - -
<br />- ANODE WIRES (INSTALL)
<br />ATTENTION FOREMAN:
<br />CATHODE WIRES (INSTALL)
<br />NOTIFY THE CORROSION DEPT. AT
<br />(925) 285-7838, 48 HOURS PRIOR TO
<br />EXISTING SERVICE
<br />START OF WORK.
<br />RAILROAD TRACK CENTER LINEATTENTION
<br />CD
<br />FOREMAN
<br />PROPERTY LINE
<br />PRIOR TO STARTING JOB, CONSULT AREA
<br />w
<br />o
<br />M
<br />z
<br />CORROSION MECHANIC FOR LOCATING WIRE
<br />o
<br />FOG LINE
<br />INSTALLATION AND CATHODIC PROTECTION
<br />C/7
<br />z
<br />=
<br />ANODE WIRES (EXISTING)
<br />REQUIREMENTS
<br />• •
<br />z
<br />o
<br />M
<br />¢
<br />•.
<br />- - - - - -
<br />- CATHODE WIRES (EXISTING)
<br />Installation Tested or Inspected
<br />'•
<br />o
<br />w
<br />z
<br />and Noted on Drawing.
<br />•
<br />U
<br />m
<br />o
<br />0
<br />0
<br />DEEP WELL ANODE (INSTALL)
<br />All Corrosion Levels Satisfactory per
<br />w
<br />V)
<br />Y
<br />T
<br />RECTIFIER (INSTALL)
<br />PG&E Gas Utility Standard TD -4181S.
<br />iz
<br />~
<br />w
<br />>
<br />o
<br />Lo
<br />J 0 B DATA
<br />Cn
<br />z
<br />0
<br />¢
<br />¢
<br />�'
<br />11,91
<br />GROUND ROD (INSTALL)
<br />O
<br />DEEP WELL ANODE (EXISTING)
<br />CITY: STOCKTON
<br />U
<br />�
<br />=
<br />Qualified Employee Date
<br />COUNTY: SAN JOAQUIN
<br />C/)
<br />RECTIFIER (EXISTING)
<br />PLAT: 2947 F7 BLOCK 21
<br />/ /
<br />Q
<br />�
<br />Corrosion mechanics signature is required when a
<br />CPA boundary is the the
<br />CPA: 2947
<br />(-D
<br />O
<br />PG&E POLE (EXISTING)
<br />within scope of project
<br />TBA: X-02
<br />•
<br />METER PROTECTION POST
<br />MAOP: 60
<br />NOP: 54
<br />APD:
<br />EZ: 16 -ST -03-B
<br />Z
<br />0
<br />G
<br />5 4 3
<br />2 1 INCH 0
<br />
|