Laserfiche WebLink
24801 S LAMMERS ROAD0+00CL <br />0+16 EOP <br />0+30 R/W <br />14' DIRT DRIVEWAYEXIST. PEDEXIST. POLE#24823EXIST. MH#499S LAMMERS RD <br />0+00CLCAPITAL PARK DRCP TEST VALVE10+16 EOP <br />0 + 30 R/W <br />747'2325'14' DIRT P/L155'24733 S LAMMERS ROADFENCEVZ PED25'45'N POLEFOCFACE OF CURBPROPOSED CONDUITR/WRIGHT OF WAYCLCENTERLINELEGENDBOSBACK OF SIDEWALKSSTOP SIGNCSWCONCRETE SIDEWALKCONSTRUCTION NOTESSAFETY NOTE WORK AREA WILL INCLUDE LANECLOSURE ON ROAD WITH VERY HIGHTRAFFIC VOLUME. PLEASE PROVIDECOMPLETE WORK AREA PROTECTION.GENERAL NOTES:1. CONTRACTOR SHALL REQUEST LOCATION OFUNDERGROUND FACILITIES BY USA2. CONTRACTOR WILL COMPLY WITH ALLCITY OF TRACY REGULATIONS FOR SPLICE PIT &SURFACE COMPACTION3. CONTRACTOR WILL RETURN WORK AREA BACKTO ORIGINAL OR BETTER CONDITION PRIOR TOSTART OF WORK4. MAINTAIN 36" MINIMUM COVEREXCAVATION DATAEOPEDGE OF PAVEMENT1FOLLOW PROCEDURES AS DETAILED INNORTHERN SECTOR PLAN FOR PROTECTIONOF UNDERGROUND AND BURIED CABLEM.O.P. DATEDM.O.P REQUIREDCATEGORY - 3Call USA @ 81148hrs prior to start of workFENCE CHC Consulting04/23/20201/2"0'1"0'30'15'DIG 4'X4' BORE PIT2VIA BOREPM 1 DU 155'PL. 155' 1-4'' DUCTPTS 77 OR EQUIV.3DIG 4'X6' RECEIVE PIT& PL. NEW 3'X5' SB36" Min. Cover12"Existing GradeBelow Existing GradeTYPICAL BORE DETAILTYPICAL CONDUIT DEPTH DETAIL (DIRT)(AT&T)1-4'' DUCTNO SCALE4VIA TRENCHPM 1 DU 5'PL. 5' 1-4'' DUCTPTS 77 OR EQUIV.NO SCALECement Slurry Backfill(AT&T)PROPOSED EXCAVATIONREPLACE BASE AND FINISHEDSURFACE EQUAL TO OR GREATERTHAN EXISTING AS PER AGENCYSTANDARDS AND APPROVAL OFCITY, COUNTY OR STATE INSPECTOR.36" Min. Cover12"Existing GradeBelow Existing GradeTYPICAL CONDUIT DEPTH DETAIL (DIRT)TYPICAL TRENCH DETAIL1-4'' DUCT