My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Permits & Development - Encroachment(EP)/Driveway(DW) Permits - 2020_PS-2001001 thru PS-2001500_ - PS-2001182
PublicWorks
>
- PUBLIC SERVICES
>
PERMITS & DEVELOPMENT
>
Encroachment(EP)/Driveway(DW) Permits
>
2020
>
PS-2001001 thru PS-2001500
>
Permits & Development - Encroachment(EP)/Driveway(DW) Permits - 2020_PS-2001001 thru PS-2001500_ - PS-2001182
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/20/2023 10:24:59 AM
Creation date
1/20/2023 10:23:23 AM
Metadata
Fields
Template:
Permits_Development
DocName
PS-2001182
Category07
Encroachment(EP)/Driveway(DW) Permits
Year2
2020
Notes2
24801 Lammers Rd.
Address
5555 E. Olive RM#300111, Fresno,CA 93727
Application
AT&T-Fresno
Type
Bell Hole; Trench
Supplemental fields
Cross Ref
PWP730079
Type (2)
Encroachment Permit (EP)
Text box
ID:
1
Creator:
Created:
1/20/2023 10:23 AM
Modified:
1/20/2023 10:23 AM
Text:
SAN JOAQUIN COUNTY
ID:
2
Creator:
Created:
1/20/2023 10:23 AM
Modified:
1/20/2023 10:23 AM
Text:
SAN JOAQUIN
ID:
3
Creator:
Created:
1/20/2023 10:23 AM
Modified:
1/20/2023 10:23 AM
Text:
COUNTY
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
12
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
24801 S LAMMERS ROAD0+00CL <br />0+16 EOP <br />0+30 R/W <br />14' DIRT DRIVEWAYEXIST. PEDEXIST. POLE#24823EXIST. MH#499S LAMMERS RD <br />0+00CLCAPITAL PARK DRCP TEST VALVE10+16 EOP <br />0 + 30 R/W <br />747'2325'14' DIRT P/L155'24733 S LAMMERS ROADFENCEVZ PED25'45'N POLEFOCFACE OF CURBPROPOSED CONDUITR/WRIGHT OF WAYCLCENTERLINELEGENDBOSBACK OF SIDEWALKSSTOP SIGNCSWCONCRETE SIDEWALKCONSTRUCTION NOTESSAFETY NOTE WORK AREA WILL INCLUDE LANECLOSURE ON ROAD WITH VERY HIGHTRAFFIC VOLUME. PLEASE PROVIDECOMPLETE WORK AREA PROTECTION.GENERAL NOTES:1. CONTRACTOR SHALL REQUEST LOCATION OFUNDERGROUND FACILITIES BY USA2. CONTRACTOR WILL COMPLY WITH ALLCITY OF TRACY REGULATIONS FOR SPLICE PIT &SURFACE COMPACTION3. CONTRACTOR WILL RETURN WORK AREA BACKTO ORIGINAL OR BETTER CONDITION PRIOR TOSTART OF WORK4. MAINTAIN 36" MINIMUM COVEREXCAVATION DATAEOPEDGE OF PAVEMENT1FOLLOW PROCEDURES AS DETAILED INNORTHERN SECTOR PLAN FOR PROTECTIONOF UNDERGROUND AND BURIED CABLEM.O.P. DATEDM.O.P REQUIREDCATEGORY - 3Call USA @ 81148hrs prior to start of workFENCE CHC Consulting04/23/20201/2"0'1"0'30'15'DIG 4'X4' BORE PIT2VIA BOREPM 1 DU 155'PL. 155' 1-4'' DUCTPTS 77 OR EQUIV.3DIG 4'X6' RECEIVE PIT& PL. NEW 3'X5' SB36" Min. Cover12"Existing GradeBelow Existing GradeTYPICAL BORE DETAILTYPICAL CONDUIT DEPTH DETAIL (DIRT)(AT&T)1-4'' DUCTNO SCALE4VIA TRENCHPM 1 DU 5'PL. 5' 1-4'' DUCTPTS 77 OR EQUIV.NO SCALECement Slurry Backfill(AT&T)PROPOSED EXCAVATIONREPLACE BASE AND FINISHEDSURFACE EQUAL TO OR GREATERTHAN EXISTING AS PER AGENCYSTANDARDS AND APPROVAL OFCITY, COUNTY OR STATE INSPECTOR.36" Min. Cover12"Existing GradeBelow Existing GradeTYPICAL CONDUIT DEPTH DETAIL (DIRT)TYPICAL TRENCH DETAIL1-4'' DUCT
The URL can be used to link to this page
Your browser does not support the video tag.