Permits & Development - Encroachment(EP)/Driveway(DW) Permits - 2020_PS-2002001 thru PS-2002500_ - PS-2002247
PublicWorks
>
- PUBLIC SERVICES
>
PERMITS & DEVELOPMENT
>
Encroachment(EP)/Driveway(DW) Permits
>
2020
>
PS-2002001 thru PS-2002500
>
Permits & Development - Encroachment(EP)/Driveway(DW) Permits - 2020_PS-2002001 thru PS-2002500_ - PS-2002247
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/24/2023 2:10:35 PM
Creation date
1/24/2023 2:09:05 PM
Metadata
Fields
Template:
Permits_Development
DocName
PS-2002247
Category07
Encroachment(EP)/Driveway(DW) Permits
Year2
2020
Notes2
1011 N. Broadway Ave.
Address
12687 S. Manthey Rd., Lathrop,CA 95330
Application
Comcast/SEFNCO
Type
Bore (up to 12 inch Dia)
Supplemental fields
Cross Ref
PWP7110005
Type (2)
Encroachment Permit (EP)
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
17
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
SHEET: CD-0 <br />THIS IS A COMCAST DOCUMENT, PROPRIETARY & CONFIDENTIAL <br />GENERAL NOTES <br />•CONTRACTOR SHALL VERIFY ALL FOOTAGES ON SITE, PRIOR TO THE START OF <br />CONSTRUCTION. ALL DIMENSIONS SHOWN ON PLANS ARE APPROXIMATE. <br />•CONTRACTOR SHALL WORK ONLY DURING APPROVED HOURS, UNLESS OTHERWISE <br />APPROVED IN WRITING BY THE “CITY/COUNTY ENGINEER.” <br />•CONTRACTOR SHALL NOTIFY THE PUBLIC WORKS INSPECTOR 48 HOURS IN ADVANCE OF <br />WORK COMMENCING. <br />•CONTRACTOR SHALL POTHOLE/HAND DIG AND VERIFY ALL UNDERGROUND UTILITIES PRIOR <br />TO THE START OF CONSTRUCTION. ALL UTILITY LOCATIONS ON PLANS ARE APPROXIMATE, <br />CONTRACTOR MUST VERIFY. <br />•CONTRACTOR SHALL KEEP A COPY OF APPROVED PLAN(S) AND PERMIT(S) AT THE JOB SITE <br />AT ALL TIMES AND PRESENT IT TO AN AUTHORIZED AGENT OF THE CITY/COUNTY AND/OR <br />LAW ENFORCEMENT UPON REQUEST. <br />•CONTRACTOR SHALL ENSURE ALL WORK PERFORMED IS IN ACCORDANCE WITH <br />REGULATIONS AND STANDARDS SET BY ANY AND ALL REGULATORY AGENCIES HAVING <br />JURISDICTION AT THIS WORK SITE, INCLUDING BUT NOT LIMITED TO THE STATE OF <br />CALIFORNIA PUBLIC UTILITY COMMISSION (CPUC), THE STATE OF CALIFORNIA <br />OCCUPATIONAL SAFETY AND HEALTH ACT (CAL OSHA), THE COUNTY AND THE CITY. <br />•CONTRACTOR SHALL NOTIFY UNDERGROUND SERVICE ALERT (USA), AT LEAST 48 HOURS <br />(AND NOT MORE THAN 14 DAYS) PRIOR TO THE START OF CONSTRUCTION BY CALLING (800) <br />227-2600. <br />•ALL WORK SHALL BE ACCESSIBLE AND SUBJECT TO INSPECTION BY THE CITY/COUNTY <br />ENGINEER AND/OR AN AUTHORIZED AGENT OF COMCAST. <br />•CONTRACTOR SHALL NOTIFY BUSINESS ESTABLISHMENTS/OWNERS AFFECTED BY THE WORK <br />AT LEAST 72 HOURS IN ADVANCE OF CONSTRUCTION. <br />•ALL GENERAL NOTES SHALL APPLY TO ALL DRAWINGS, PLANS AND DETAILS. <br />•CONTRACTOR SHALL ENSURE THAT ANY EXISTING FACILITIES DAMAGED OR REMOVED SHALL <br />BE REPLACED IN KIND OR BETTER, INCLUDING BUT NOT LIMITED TO REPLACING EXISTING <br />STRIPING AND REMOVING UNNECESSARY “USA” MARKINGS. <br />•CONTRACTOR SHALL PERFORM ALL WORK AND TRAFFIC CONTROL IN ACCORDANCE WITH <br />THE CITY/COUNTY AND STATE OF CALIFORNIA STANDARD PLANS AND SPECIFICATIONS, AND <br />CURRENT CALIFORNIA DEPARTMENT OF TRANSPORTATION “MANUAL OF TRAFFIC CONTROLS <br />AND MAINTENANCE OF HAZARD ZONE” AND “MANUAL OF WARNING SIGNS, LIGHTS AND <br />DEVICES” FOR USE IN PERFORMANCE OF WORK UPON HIGHWAYS. FLASHING ARROW SIGNS <br />SHALL BE REQUIRED FOR ALL LANE CLOSURES. <br />BORE PIT <br />WATER MANHOLE <br />UNIDENTIFIED MANHOLE <br />GAS METER <br />WATER METER <br />ELECTRIC MANHOLE <br />SEWER CLEAN OUT <br />SANITARY SEWER MANHOLE <br />STORM DRAIN MANHOLE <br />CATCH BASIN <br />GAS/WATER VALVE <br />TREE/BUSHES <br />EXISTING POLE <br />EXISTING COMCAST PEDESTAL <br />POTHOLE <br />EXISTING IRRIGATION VAULT <br />EXISTING COMCAST VAULT <br />EXISTING UTILITY VAULT/PEDESTAL <br />MONUMENT <br />FIRE HYDRANT <br />TRAFFIC SIGNAL COMBINATION <br />STREET LIGHT <br />TRANSFORMER <br />NEW COMCAST LOW PROFILE <br />NEW COMCAST PEDESTAL <br />NEW COMCAST VAULT <br />POWER SUPPLY W/ METER <br />NEW COMCAST POWER SUPPLY <br />NEW RISER ATTACHED TO POLE <br />TV <br />T <br />E <br />G <br />SS <br />SD <br />W <br />ROADWAY CENTER LINE <br />EXISTING COMCAST ROUTE <br />EXISTING FENCELINE <br />PROPOSED TRENCH/BORE ROUTE <br />EXISTING WATER LINE <br />EXISTING STORM DRAIN <br />EXISTING SANITARY SEWER <br />IRR EXISTING IRRIGATION SYSTEM <br />EXISTING GAS SYSTEM <br />EXISTING ELECTRICAL SYSTEM <br />EXISTING TELEPHONE SYSTEM <br />PROPERTY LINE <br />TV EXISTING TV SYSTEM <br />JT EXISTING JOINT TRENCH <br />BOW <br />(N) <br />(T) <br />DWY <br />CNDT <br />C/L <br />COMCAST <br />(E) <br />FOC <br />MIN <br />MAX <br />NEW <br />BACK OF WALK <br />MAXIMUM <br />COMCAST <br />CENTER LINE <br />EXISTING <br />FACE OF CURB <br />MINIMUM <br />DRIVEWAY <br />TEMPORARY <br />CONDUIT <br />SD <br />PL <br />PUE <br />R/W <br />SS <br />T <br />W <br />E <br />G <br />EOP <br />LOG <br />PROPERTY LINE <br />EXISTING STORM DRAIN <br />EXISTING GAS <br />EDGE OF PAVEMENT <br />LIP OF GUTTER <br />PUBLIC UTILITY EASEMENT <br />EXISTING WATER <br />EXISTING TELEPHONE <br />EXISTING ELECTRIC <br />RIGHT OF WAY <br />EXISTING SANITARY SEWER <br />ABBREVIATIONS <br />LINETYPES <br />PROPOSED OVERLASH ROUTE <br />PROPOSED OVERPULL ROUTE <br />RIGHT OF WAY LINE <br />SYMBOLS <br />DESIGN: CITYRISE <br />DRAWN BY: <br />APPROVED: <br />APPROVED: <br />APPROVED: <br />LEGEND, GENERAL NOTES <br />NODE: <br />REV DESCRIPTION DATE <br />JOB#: JB358891 <br />CONSTRUCTION TYPE: Aerial, bore, new pole riser. <br />SYSTEM: County of San Joaquin <br />1011 N BROADWAY AVE
The URL can be used to link to this page
Your browser does not support the video tag.