10 <br /> <br />3.6 Post #2 Connection Detail for MSKT <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> NOTE: Be sure the 3/4" x 8 ½" hex bolt at Hinged Post #2 is on the <br /> downstream side of the post (toward post #3). <br /> <br /> <br />Figure 5. <br />E Upper Post #2 W6" x 8.5 # <br />d 5/8" x 1 ¼" Guardrail Splice Bolt <br />g 5/8" Nut <br />h ¾" x 8 ½" Hex Bolt <br />j ¾" Nut <br />Note there are two sets of open-ended slots in <br />upper post #2. This is a Universal Post used <br />for both 28” and 31” rail heights. Use the top <br />slot for the 31” MSKT terminal. Be sure upper <br />post #2 is installed with slots facing post #1. <br />When installing <br />lower Post #2 <br />DO NOT <br />pound on the <br />side plates