My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Permits & Development - Encroachment(EP)/Driveway(DW) Permits - 2020_PS-2003001 thru PS-2003500_-PS-2003022
PublicWorks
>
- PUBLIC SERVICES
>
PERMITS & DEVELOPMENT
>
Encroachment(EP)/Driveway(DW) Permits
>
2020
>
PS-2003001 thru PS-2003500
>
Permits & Development - Encroachment(EP)/Driveway(DW) Permits - 2020_PS-2003001 thru PS-2003500_-PS-2003022
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/3/2023 10:51:15 AM
Creation date
2/3/2023 10:49:12 AM
Metadata
Fields
Template:
Permits_Development
DocName
PS-2003022
Category07
Encroachment(EP)/Driveway(DW) Permits
Year2
2020
Notes2
E/S of Hansen Rd. 50' N/O Von Sosten Rd.
Address
PO Box 930, Stockton,CA 95201
Application
Pacific Gas & Electric-Stockton
Type
Trench
Supplemental fields
Cross Ref
PWP730052
Type (2)
Encroachment Permit (EP)
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
17
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
CABINET DETAIL(N.T.S)(TYPICAL)GRADENOTE:SCADA CABINET DIMENSIONS: 63"H x 40"L x 24"WCABINET PAD DIMENSIONS: 45"L x 30"W x 21"D63"30"45"24"40"21"CABINET DETAILNOTES:CONCRETE STRENGTH:-ALL CONCRETE SHALL HAVE A MIN. 28 DAY COMPRESSIVE STRENGTH OF 2500 PSI, UNLESS OTHERWISE NOTED ON DRAWING.-CEMENT SHALL BE PORTLAND CEMENT CONFORMING TO ASTM C 150 TYPE II.-THE MAXIMUM SLUMP OF CONCRETE SHALL BE 4", UNLESS NOTED ON THE DRAWING.-THE CEMENT-WATER RATIO SHALL BE 0.45 BY WEIGHT.REINFORCEMENT:-REINFORCEMENT SHALL BE IN ACCORDANCE WITH THE ASTM-615, GRADE 60 DEFORMED STEEL BARS (YIELD STRENGTH OF Fy=60,000 PSI)GRADE 40 STEEL BARS FOR #4 & SMALLER BARS (YIELD STRENGTH OF Fy=40,000 PSI).-CONCRETE COVERAGE (CLEAR) FOR REINFORCEMENT SHALL BE AS FOLLOWS:CONCRETE PLACED AGAINST EARTH (BOTTOM ONLY) - 3"FORMED SURFACED EXPOSED TO WEATHER OR GROUND - 2"EXCAVATION AND FILLING:-FIELD VERIFY LOCATION OF ALL UNDERGROUND LINES PRIOR TO EXCAVATION.-STRUCTURAL FILL SHALL CONSIST OF EITHER CALTRANS CLASS 2 A/B OR 1/4" TO 3/4" CRUSHED ROCK.-COMPACTED FILL MATERIAL TO 90% ASTM D-1557 METHOD OF COMPACTION.CABINET DETAIL(N.T.S)(TYPICAL)14"REBOUNDABLE DELINEATOR(N.T.S)48"3" OD x 48" LONG TUBE,HIGH DENSITYPOLYETHYLENE(ORANGE)VISIBILITY STRIPS14"(SURFACE MOUNTED)SEE PAGE 6 FOR DELINEATOR SPECIFICATIONS2-1/2" x 1/2" DUAL-LEADTHREAD HEX HEADCONCRETE ANCHORCONCRETESONOTUBE
The URL can be used to link to this page