Laserfiche WebLink
SAN JOAQUIN COUNTY PERMIT LENGTH: 126 FT <br />CONSTRUCTION TOTALS <br />I MATERIAL TOTALS <br />BORE <br />118 <br />LF <br />1.25'0 HOPE CONDUIT <br />126 <br />LF <br />CASED BORE <br />— <br />LF <br />4—WAY FUTURE PATH <br />125 <br />LF <br />TRENCH <br />8 <br />LF <br />10/12mm MICROOUCT <br />126 <br />LF <br />PLOW <br />— <br />LF <br />4°0 CASING <br />— <br />LF <br />BRIDGE ATTACHMENT <br />LF <br />3/4'0 EMT PIPE <br />LF <br />CONDUIT OVERRIDE <br />LF <br />TRACEABLE MULE TAPE <br />126 <br />LF <br />AERIAL <br />-- <br />LF <br />ESTIMATED FIBER <br />300 <br />LF <br />AERIAL STRAND <br />LF <br />SLACK LOOPS <br />2 <br />POLE RISER <br />1 <br />24.36.24 HANDHOLES <br />2 <br />BORE PITS <br />2 <br />BARREL VAULT <br />-- <br />d <br />E <br />MARKER POST (EST.) <br />CONTRACTOR NOTICE: <br />THE EXISTENCE AND LOCATION OF ANY UNDERGROUND UTILITY PIPES OR <br />STRUCTURES SHOWN ON THESE PLANS WERE OBTAINED BY FIELD INSPECTION AND A SEARCH OF THE <br />AVAILABLE CITY OR COUNTY RECORDS. SINCE THE ACTUAL LOCATION AND NATURE OF THE UNDERGROUND <br />FACILITIES MAY BE SOMEWHAT DIFFERENT FROM THAT SHOWN, THE CONTRACTOR IS REQUIRED TO VERIFY <br />THE INFORMATION THROUGH UNDERGROUND SERVICE ALERT (USA) OR BY CONTACTING THE UTILITY <br />COMPANIES DIRECTLY, PRIOR TO EXCAVATION. <br />GENERAL NOTES: <br />THE FOLLOWING NOTES ARE PROVIDED TO GIVE DIRECTIONS TO THE CONTRACTOR BY THE ENGINEER OF <br />WORK. THE PERMIT AGENCY'S SIGNATURE ON THESE PLANS DOES NOT CONSTITUTE APPROVAL OF THESE <br />NOTES AND THAT AGENCY WILL NOT BE RESPONSIBLE FOR THEIR ENFORCEMENT: <br />1. THE LOCATIONS OF EXISTING UTILITIES, RIGHTS—OF—WAY AND EASEMENTS SHOWN ON THESE PLANS <br />ARE BASED ON AVAILABLE RECORDS AND ARE APPROXIMATE IN NATURE. WHERE CONFLICTS EXIST <br />WITHIN THE RECORDS OR BETWEEN THE RECORDS AND FIELD OBSERVATIONS, THE ENGINEER OF <br />WORK ASSUMES NO RESPONSIBILITY FOR THE CORRECTNESS OF THAT INFORMATION AS DEPICTED. <br />2, PRIOR TO COMMENCING IMPROVEMENT OPERATIONS, THE CONTRACTOR SHALL VERIFY THE LOCATION, <br />BOTH HORIZONTALLY AND VERTICALLY, OF ALL EXISTING FACILITIES AFFECTED BY THE PROPOSED <br />WORK, WHETHER OR NOT THOSE FACILITIES ARE DEPICTED CORRECTLY ON THESE PLANS. <br />3, IF EXISTING FACILITIES VARY SIGNIFICANTLY IN LOCATION OR DEPTH FROM THESE PLANS, THE <br />ENGINEER OF WORK SHOULD BE NOTIFIED TO MAKE ANY DESIGN CHANGES REQUIRED. <br />4, THE CONTRACTOR SHALL BE TOTALLY RESPONSIBLE FOR COMPLIANCE WITH THE PROVISIONS OF THE <br />STATE OF CALIFORNIA SAFETY ORDERS. <br />5. THE CONTRACTOR AGREES THAT HE SHALL ASSUME SOLE RESPONSIBILITY FOR JOB SITE CONDITIONS <br />DURING THE COURSE OF CONSTRUCTION OF THIS PROJECT INCLUDING SAFETY OF ALL PERSONS AND <br />PROPERTY; THAT THIS REQUIREMENT SHALL APPLY CONTINUOUSLY AND NOT BE LIMITED TO NORMAL <br />WORKING HOURS; AND THAT THE CONTRACTOR SHALL DEFEND, INDEMNIFY AND HOLD THE OWNER <br />AND THE ENGINEER OF WORK HARMLESS. <br />6. THE BORE LOCATIONS INDICATED ON THE STAKING SHEETS ARE THE ENGINEER'S BEST ESTIMATE OF <br />LOCATION AND LENGTH AS REQUIRED TO MEET JURISDICTIONAL REQUIREMENTS AND/OR TO AVOID <br />SURFACE OR OTHER DAMAGE THAT MAY BE ASSOCIATED WITH TRADITIONAL TRENCHING OR PLOWING <br />METHODS. INSPECTOR & CONTRACTOR SHALL REVIEW ALL FIELD CONDITIONS PRIOR TO <br />CONSTRUCTION AND VERIFY THAT THE INDICATED BORE UNITS ARE ACCURATELY IDENTIFIED, <br />APPROPRIATELY LOCATED AND ACTUALLY REQUIRED (NOTIFY ENGINEER AND /OR OWNER OF ANY <br />DISCREPANCIES). IF A BORE UNIT CAN BE ELIMINATED, WITH THE APPROVAL OF THE PERMITTING <br />AUTHORITY AND WITH AN ASSOCIATED NET COST SAVINGS, THEN THE BORE UNIT SHALL BE <br />ELIMINATED. ALSO, NOTIFY ENGINEER AND /OR OWNER OF ADDITIONAL BORES THAT ARE REQUIRED, <br />BUT ARE NOT INDICATED ON THE STAKING SHEETS. <br />7, THE HANOHOLE/VAULT LOCATIONS INDICATED ON THE STAKING SHEETS ARE THE ENGINEER'S BEST <br />ESTIMATE OF LOCATION FOR PLACING THE UNIT AS REQUIRED TO MEET CVIN, JURISDICTIONAL <br />AND/OR SAFETY REQUIREMENTS AND TO PROVIDE AN APPROPRIATE LOCATION THAT WILL ALLOW FOR <br />PARKING, EASE OF ACCESS AND ADEQUATE SPACE TO PERFORM INSTALLATION AND MAINTENANCE <br />WORK. IN HIGHWAY LOCATIONS WHERE THE CONDUIT RUNNING LINE IS INDICATED TO BE IN THE <br />ROAD SHOULDER NEAR THE EDGE OF ASPHALT, THE HANDHOLES SHALL BE PLACED AT LEAST 20 <br />FEEL AWAY FROM THE FOG LINE (BEYOND THE CLEAR RECOVERY ZONE), IN A SAFE LOCATION AWAY <br />FROM ANY BIOLOGICAL OR CULTURAL AVOIDANCE AREAS. CONDUIT SHALL ENTER AND EXIT THE <br />HANDHOLE USING SEPARATE TRENCHES AT 45—DEGREES TO THE ROADWAY TO MAINTAIN ROUTE <br />DIVERSITY. INSPECTOR & CONTRACTOR SHALL REVIEW ALL FIELD CONDITIONS PRIOR TO <br />CONSTRUCTION AND VERIFY THAT ALL INDICATED UHF UNITS ARE APPROPRIATELY LOCATED. FINAL <br />POSITION OF UHF MAY BE RELOCATED IF A MORE APPROPRIATE POSITION CAN BE IDENTIFIED <br />NEARBY. (NOTIFY ENGINEER AND/OR OWNER OF ANY DISCREPANCIES & ADJUSTMENTS). ALSO, <br />NOTIFY ENGINEER AND/OR OWNER OF ADDITIONAL HANDHOLES THAT MAY BE REQUIRED, BUT ARE NOT <br />INDICATED ON THE STAKING SHEETS. <br />8, CONTRACTOR SHALL PROVIDE COMPLETE AS—BUILT PLANS, WITH GPS COORDINATES IN NAD -83 <br />FORMAT, WITH SUB—METER ACCURACY (NOOD.00000000, W000.00000000) FOR ALL CONDUIT SPLICE <br />POINTS, HANDHOLES AND ROAD CROSSING LOCATIONS, PER CVIN SPECIFICATIONS. <br />9. CONTRACTOR SHALL SUPPLY AND INSTALL (1) 18AWG SOLID COPPER TRACER WIRE (RED INSULATION) <br />WITH 1.25" CONDUIT (IF NOT INCLUDED WITH FUTURE PATH CONDUIT). SPLICE AS REQUIRED WITH <br />GEL—FILLED WIRE NUTS TO ASSURE CONTINUITY. <br />CVIN, LLC <br />SAN JOAQUIN COUNTY PERMIT PLANS <br />INSTALLATION OF FIBER OPTIC FACILITIES <br />NAUTILUS DATA TECHNOLOGIES, INC <br />1002 EMBARCADERO, STOCKTON, 95203 <br />WORK ALONG MARIPOSA RD. <br />INDEX: <br />SHEET 1 COVER AND KEYMAP <br />SHEET 2-3 HANDHOLE AND CONDUIT DETAILS <br />SHEET 4 TYPICAL BORE DETAILS <br />SHEET 5 TYPICAL TRAFFIC CONTROL PLANS <br />SHEET 6 PERMIT PLANS <br />CONTRACTOR NOTICE: <br />THE EXISTENCE AND LOCATION OF ANY UNDERGROUND UTILITY PIPES OR <br />STRUCTURES SHOWN ON THESE PLANS WERE OBTAINED BY FIELD INSPECTION AND A SEARCH OF THE <br />AVAILABLE CITY OR COUNTY RECORDS. SINCE THE ACTUAL LOCATION AND NATURE OF THE UNDERGROUND <br />FACILITIES MAY BE SOMEWHAT DIFFERENT FROM THAT SHOWN, THE CONTRACTOR IS REQUIRED TO VERIFY <br />THE INFORMATION THROUGH UNDERGROUND SERVICE ALERT (USA) OR BY CONTACTING THE UTILITY <br />COMPANIES DIRECTLY, PRIOR TO EXCAVATION. <br />CVIN GENERAL CONSTRUCTION NOTES: <br />1. ALL CONDUITS, HANOHOLE/VAULTS AND WARNING SIGNS SHALL BE SUPPLIED BY CVIN. ALL OTHER <br />MATERIALS INCLUDING CASING, RISERS, ENTRANCE PIPE AND INSIDE RACEWAY SHALL BE SUPPLIED BY <br />THE CONTRACTOR. <br />2. ALL CVIN SUPPLIED MATERIAL TO BE PICKED UP BY CONTRACTOR AT CVIN STORAGE YARD AT <br />1742 W. PINE FRESNO CA 93728. CONTRACTOR TO RETURN ALL EXTRA OR UNUSED MATERIALS <br />TO CVIN YARD UPON COMPLETION OF THE PROJECT. <br />3. MATERIAL TO BE INSPECTED BY CONTRACTOR AND CVIN REPRESENTATIVE TO ENSURE QUALITY OF <br />MATERIALS. <br />4, CONTRACTOR TO WALK PROJECT AND CONFIRM TRENCH LOCATIONS, BORE LOCATIONS AND <br />HAN DHOLE/MANHOLE LOCATIONS PRIOR TO THE START OF CONSTRUCTION. CONFIRM ANY PROPOSED <br />CHANGES IN WRITING WITH CVIN REPRESENTATIVE. <br />5, CONTRACTOR TO INSTALL PER CVIN SPECIFICATIONS AND DETAILS ATTACHED. <br />6, CVIN REPRESENTATIVE TO BE PRESENT TO INSPECT WORK PERFORMED FOR CVIN AT CALTRANS AND <br />RAILROAD CROSSINGS. <br />7. UPON COMPLETION OF CONSTRUCTION, CONTRACTOR TO CLEAN AND PROOF ALL DUCTS TO ENSURE <br />PROPER INSTALLATION. <br />B. CONTRACTOR TO PLUG ALL CONDUITS PLACED USING SUPPLIED CONDUIT PLUGS. <br />9. CONTRACTOR SHALL SUPPLY AND INSTALL (1) 16AWG SOLID COPPER TRACER WIRE (RED INSULATION) <br />WITH 1.25" CONDUIT (IF NOT INCLUDED WITH FUTURE PATH CONDUIT). SPLICE As REQUIRED WITH <br />GEL—FILLED WIRE NUTS TO ASSURE CONTINUITY. <br />10, CONTRACTOR SHALL SUPPLY AND INSTALL MULE TAPE IN 1.25"0 HDPE DUCT CONTINUOUS FROM <br />FROM BEGINNING TO END. PROVIDE 30' SLACK AT BEGINNING AND END HANDHOLES. <br />11, WARNING SIGNS AND DECALS SHALL BE SUPPLIED BY OWNER. CONTRACTOR SHALL NOTIFY OWNER OF <br />ALL MID—SPAN CONDUIT SPLICES AS THAT QUANTITY IS NOT ACCOUNTED FOR IN THE BID UNIT <br />QUANTITY SUMMARY. <br />12, CONTRACTOR SHALL POST FIBER WARNING SIGNS, EVERY 3264Dft IN RURAL AREAS AND 31320ft IN <br />URBAN AREAS, AT EVERY HANDHOLE, BOTH SIDES OF ROAD CROSSING AND CHANGES IN DIRECTION, <br />CONDUIT SPLICE LOCATED BETWEEN HANDHOLES (EXCEPT IN SIDEWALKS OR OTHER IMPRACTICAL <br />URBAN AREAS). MARKERS SHALL BE PLACED IN AS CLOSE PROXIMITY AS POSSIBLE TO PERMANENT <br />OBJECTS TO PROVIDE PROTECTION, WITHOUT OBSCURING THE MARKER FROM VIEW. MARKERS SHALL <br />BE ORIENTATED AND PLACED FOR MAXIMUM VISIBILITY. IN RURAL AREAS THE DECAL SHALL FACE <br />ONCOMING TRAFFIC TO BE VISIBLE TO A DRIVER. <br />13, CONTRACTOR SHALL PROVIDE COMPLETE AS—BUILT PLANS TO IDENTIFY RUNNING LINE LOCATION. <br />PROVIDE GPS COORDINATES IN NAD -83 FORMAT, WITH SUB—METER ACCURACY (N000.00000000, <br />W000.00000000) FOR ALL CONDUIT SPLICE POINTS, HANDHOLES, CHANGES IN DIRECTION AND ROAD <br />CROSSING LOCATIONS, PER CVIN SPECIFICATIONS. <br />14, CONTRACTOR SHALL PROVIDE CERTIFICATION LETTER STATING THAT ALL CONDUITS AND HANDHOLES <br />HAVE BEEN INSTALLED, CLEANED AND TESTED PER CVIN SPECIFICATIONS. <br />15. CONTRACTOR SHALL PROVIDE CERTIFICATION LETTER STATING THAT TRACER WIRE HAS BEEN INSTALLED <br />PER CAN SPECIFICATIONS AND TESTED TO CONFIRM CONTINUITY FROM BEGINNING TO END, <br />W&nrt s mee P.e <br />'&-o <br />&46aRve> <br />a <br />aa�tiv�as <br />� <br />s <br />Rune. <br />Wp <br />SecJon Pva <br />\g. e`pL <br />na <br />ca-e^\wnw+ <br />Pa <br />3 <br />e <br />wyrr>;BAP <br />d <br />E <br />9cp <br />n <br />>� <br />. s <br />E.\n <br />5 <br />� <br />M enh SE <br />fen^,nS <br />M� <br />Earns` <br />2 <br />aacav s. <br />a,°+a <br />ion9Wna o� A, XV <br />Mpn¢\o <br />� a <br />EB ; <br />ny <br />o <br />a6 <br />4 <br />4 <br />eemn S e9 a.s <br />aano' sl <br />fe n,s <br />a <br />Ea&5t <br />um <br />e <br />JOB SITE <br />VICINITY MAP <br />INDEX: <br />SHEET 1 COVER AND KEYMAP <br />SHEET 2-3 HANDHOLE AND CONDUIT DETAILS <br />SHEET 4 TYPICAL BORE DETAILS <br />SHEET 5 TYPICAL TRAFFIC CONTROL PLANS <br />SHEET 6 PERMIT PLANS <br />CONTRACTOR NOTICE: <br />THE EXISTENCE AND LOCATION OF ANY UNDERGROUND UTILITY PIPES OR <br />STRUCTURES SHOWN ON THESE PLANS WERE OBTAINED BY FIELD INSPECTION AND A SEARCH OF THE <br />AVAILABLE CITY OR COUNTY RECORDS. SINCE THE ACTUAL LOCATION AND NATURE OF THE UNDERGROUND <br />FACILITIES MAY BE SOMEWHAT DIFFERENT FROM THAT SHOWN, THE CONTRACTOR IS REQUIRED TO VERIFY <br />THE INFORMATION THROUGH UNDERGROUND SERVICE ALERT (USA) OR BY CONTACTING THE UTILITY <br />COMPANIES DIRECTLY, PRIOR TO EXCAVATION. <br />CVIN GENERAL CONSTRUCTION NOTES: <br />1. ALL CONDUITS, HANOHOLE/VAULTS AND WARNING SIGNS SHALL BE SUPPLIED BY CVIN. ALL OTHER <br />MATERIALS INCLUDING CASING, RISERS, ENTRANCE PIPE AND INSIDE RACEWAY SHALL BE SUPPLIED BY <br />THE CONTRACTOR. <br />2. ALL CVIN SUPPLIED MATERIAL TO BE PICKED UP BY CONTRACTOR AT CVIN STORAGE YARD AT <br />1742 W. PINE FRESNO CA 93728. CONTRACTOR TO RETURN ALL EXTRA OR UNUSED MATERIALS <br />TO CVIN YARD UPON COMPLETION OF THE PROJECT. <br />3. MATERIAL TO BE INSPECTED BY CONTRACTOR AND CVIN REPRESENTATIVE TO ENSURE QUALITY OF <br />MATERIALS. <br />4, CONTRACTOR TO WALK PROJECT AND CONFIRM TRENCH LOCATIONS, BORE LOCATIONS AND <br />HAN DHOLE/MANHOLE LOCATIONS PRIOR TO THE START OF CONSTRUCTION. CONFIRM ANY PROPOSED <br />CHANGES IN WRITING WITH CVIN REPRESENTATIVE. <br />5, CONTRACTOR TO INSTALL PER CVIN SPECIFICATIONS AND DETAILS ATTACHED. <br />6, CVIN REPRESENTATIVE TO BE PRESENT TO INSPECT WORK PERFORMED FOR CVIN AT CALTRANS AND <br />RAILROAD CROSSINGS. <br />7. UPON COMPLETION OF CONSTRUCTION, CONTRACTOR TO CLEAN AND PROOF ALL DUCTS TO ENSURE <br />PROPER INSTALLATION. <br />B. CONTRACTOR TO PLUG ALL CONDUITS PLACED USING SUPPLIED CONDUIT PLUGS. <br />9. CONTRACTOR SHALL SUPPLY AND INSTALL (1) 16AWG SOLID COPPER TRACER WIRE (RED INSULATION) <br />WITH 1.25" CONDUIT (IF NOT INCLUDED WITH FUTURE PATH CONDUIT). SPLICE As REQUIRED WITH <br />GEL—FILLED WIRE NUTS TO ASSURE CONTINUITY. <br />10, CONTRACTOR SHALL SUPPLY AND INSTALL MULE TAPE IN 1.25"0 HDPE DUCT CONTINUOUS FROM <br />FROM BEGINNING TO END. PROVIDE 30' SLACK AT BEGINNING AND END HANDHOLES. <br />11, WARNING SIGNS AND DECALS SHALL BE SUPPLIED BY OWNER. CONTRACTOR SHALL NOTIFY OWNER OF <br />ALL MID—SPAN CONDUIT SPLICES AS THAT QUANTITY IS NOT ACCOUNTED FOR IN THE BID UNIT <br />QUANTITY SUMMARY. <br />12, CONTRACTOR SHALL POST FIBER WARNING SIGNS, EVERY 3264Dft IN RURAL AREAS AND 31320ft IN <br />URBAN AREAS, AT EVERY HANDHOLE, BOTH SIDES OF ROAD CROSSING AND CHANGES IN DIRECTION, <br />CONDUIT SPLICE LOCATED BETWEEN HANDHOLES (EXCEPT IN SIDEWALKS OR OTHER IMPRACTICAL <br />URBAN AREAS). MARKERS SHALL BE PLACED IN AS CLOSE PROXIMITY AS POSSIBLE TO PERMANENT <br />OBJECTS TO PROVIDE PROTECTION, WITHOUT OBSCURING THE MARKER FROM VIEW. MARKERS SHALL <br />BE ORIENTATED AND PLACED FOR MAXIMUM VISIBILITY. IN RURAL AREAS THE DECAL SHALL FACE <br />ONCOMING TRAFFIC TO BE VISIBLE TO A DRIVER. <br />13, CONTRACTOR SHALL PROVIDE COMPLETE AS—BUILT PLANS TO IDENTIFY RUNNING LINE LOCATION. <br />PROVIDE GPS COORDINATES IN NAD -83 FORMAT, WITH SUB—METER ACCURACY (N000.00000000, <br />W000.00000000) FOR ALL CONDUIT SPLICE POINTS, HANDHOLES, CHANGES IN DIRECTION AND ROAD <br />CROSSING LOCATIONS, PER CVIN SPECIFICATIONS. <br />14, CONTRACTOR SHALL PROVIDE CERTIFICATION LETTER STATING THAT ALL CONDUITS AND HANDHOLES <br />HAVE BEEN INSTALLED, CLEANED AND TESTED PER CVIN SPECIFICATIONS. <br />15. CONTRACTOR SHALL PROVIDE CERTIFICATION LETTER STATING THAT TRACER WIRE HAS BEEN INSTALLED <br />PER CAN SPECIFICATIONS AND TESTED TO CONFIRM CONTINUITY FROM BEGINNING TO END, <br />