| WORK L❑CATI❑N, 11966 N FURRY RD, two, ISSUE DATE 
<br />at&t I 12,2019 
<br />L❑DI (SAN J❑AQUIN COUNTY), CA 95240 
<br />DWG,2 
<br />Dorothy Mahla EHS Q Holland Imporls v 
<br />9Lle Oak 
<br />Elementary Schunl 
<br />DWG,3 
<br />0_ 0i 
<br />WORN 
<br />5132 A1 
<br />-TABLE 6C-2 2019 CALIFORNIA MUTCD- 
<br />-STOPPING SIGHT DISTANCE 
<br />AS A FUNCTION OF SPEED - 
<br />SPEED* 
<br />(MPH) 
<br />DISTANCE 
<br />(FT) 
<br />20 
<br />115 
<br />25 
<br />155 
<br />30 
<br />200 
<br />35 
<br />250 
<br />40 
<br />305 
<br />45 
<br />360 
<br />50 
<br />425 
<br />55 
<br />495 
<br />60 
<br />570 
<br />65 
<br />645 
<br />350 
<br />70 
<br />730 
<br />75 
<br />820 
<br />* POSTED SPEED, OFF-PEAK 
<br />65TH -PERCENTILE SPEED 
<br />PRIOR TO WORK STARING OR THE 
<br />ANTICIPATED OPERATING SPEED 
<br />LEGEND: 
<br />TYPE III BARRICADE W/SIGN (5'H x 4'W) 
<br />TYPE IIBARRICADE W/0 SIGN (3'H x 2'W) 
<br />-TABLE 6C-3 2019 CALIFORNIA MUTCD- 
<br />-TAPER LENGTH CRITERIA FOR 
<br />TEMPORARY TRAFFIC CONTROL ZONE - 
<br />TYPE OF TAPER 
<br />TAPER LENGTH (L)* 
<br />MERGING TAPER 
<br />A7 LEAST L 
<br />SHIFTING TAPER 
<br />AT LEAST 0.5 L 
<br />SHOULDER TAPER 
<br />AT LEAST 0.33 L 
<br />ONE LANE, TWO-WAY TRAFFIC TAPER 
<br />30 M (100FT) MAXIMUM 
<br />DOWNSTREAM TAPER 
<br />30 M (100FT) PER LANE 
<br />-TABLE 6C-4 2019 CALIFORNIA MUTCD- 
<br />-FORMULAS FOR DETERMINING TAPER LENGTH - 
<br />SPEED LIMIT 
<br />WHERE: L= TAPER LENGTH IN METERS (FEET) 
<br />W= WIDTH OF OFFSET IN METERS (FEET) 
<br />S= POSTED SPEED LIMIT, OR OFF-PEAK 
<br />85TH -PERCENTILE SPEED PRIOR TO WORK 
<br />STARTING, OR THE ANTICIPATED OPERATING 
<br />SPEED IN KM/H (MPH 
<br />28"(11cm)TRAFFIC CONES W/13"(5cm) REFLECTIVE SLEEVE TANS 
<br />FOR DAY/NIGHT USE OR DELINEATORS IF DAY USE ONLY 
<br />TRAFFIC CONE WITH CLIP ON SIGN TAN SAT 
<br />PROPOSED SIGN AND POST 
<br />SIGNALIZED INTERSECTION 
<br />FLASHING ARROWBOARD 
<br />FOC 
<br />EOP 
<br />HIGH LEVEL WARNING DEVICE WITH SIGN (FLAGTREE) 
<br />FLAGGER 
<br />TOW AWAY NO STOPPING _ TO _ (SHOW HOURS) 
<br />TOW AWAY NO STOPPING ANY TIME 
<br />WORK ZONE LIMITS 
<br />DIRECTION OF TRAFFIC 
<br />FACE OF CURB 
<br />EDGE OF PAVEMENT 
<br />5700 � 5914 
<br />-TABLE 6C-1 2019 CALIFORNIA MUTCD- 
<br />-SUGGESTED MINIMUM ADVANCE WARNING SIGN SPACING - 
<br />ROAD TYPE 
<br />(S) 
<br />TAPER LENGfH (L) 
<br />SIGNS** 
<br />AFL Network 
<br />FEET 
<br />40 MPH 
<br />OR LESS 
<br />2 
<br />L 
<br />URBAN (LOW SPEED)*25 MPH OR LESS 
<br />100 
<br />60 
<br />40 MPH 
<br />OR MORE 
<br />L=WS 
<br />WHERE: L= TAPER LENGTH IN METERS (FEET) 
<br />W= WIDTH OF OFFSET IN METERS (FEET) 
<br />S= POSTED SPEED LIMIT, OR OFF-PEAK 
<br />85TH -PERCENTILE SPEED PRIOR TO WORK 
<br />STARTING, OR THE ANTICIPATED OPERATING 
<br />SPEED IN KM/H (MPH 
<br />28"(11cm)TRAFFIC CONES W/13"(5cm) REFLECTIVE SLEEVE TANS 
<br />FOR DAY/NIGHT USE OR DELINEATORS IF DAY USE ONLY 
<br />TRAFFIC CONE WITH CLIP ON SIGN TAN SAT 
<br />PROPOSED SIGN AND POST 
<br />SIGNALIZED INTERSECTION 
<br />FLASHING ARROWBOARD 
<br />FOC 
<br />EOP 
<br />HIGH LEVEL WARNING DEVICE WITH SIGN (FLAGTREE) 
<br />FLAGGER 
<br />TOW AWAY NO STOPPING _ TO _ (SHOW HOURS) 
<br />TOW AWAY NO STOPPING ANY TIME 
<br />WORK ZONE LIMITS 
<br />DIRECTION OF TRAFFIC 
<br />FACE OF CURB 
<br />EDGE OF PAVEMENT 
<br />5700 � 5914 
<br />-TABLE 6C-1 2019 CALIFORNIA MUTCD- 
<br />-SUGGESTED MINIMUM ADVANCE WARNING SIGN SPACING - 
<br />ROAD TYPE 
<br />DISTANCE BETWEEN 
<br />SIGNS** 
<br />AFL Network 
<br />A 
<br />Services 
<br />B 
<br />C 
<br />URBAN (LOW SPEED)*25 MPH OR LESS 
<br />100 
<br />FEET 
<br />100 
<br />FEET 
<br />100 FEET 
<br />URBAN (HIGH SPEED)*MORE THAN 25 MPH TO 40 MPH 
<br />250 
<br />FEET 
<br />250 
<br />FEET 
<br />250 FEET 
<br />URBAN (HIGH SPEED)*MORE THAN 40 MPH 
<br />350 
<br />FEET 
<br />350 
<br />FEET 
<br />350 FEET 
<br />RURAL 
<br />500 
<br />FEET 
<br />500 
<br />FEET 
<br />500 FEET 
<br />EXPRESSWAY/FREEWAY 
<br />1000 
<br />FEET 
<br />1000 FEET 
<br />1000 FEET 
<br />** THE COLUMN HEADING A, B, AND C ARE THE DIMENSIONS 
<br />SHOWN IN FIGURES 6H-1 THROUGH 6H-46. THE A DIMENSION IS THE DISTANCE FROM THE TRANSITION OR 
<br />POINT OFRICiION TO FIRST SIGN. THE B DIMENSION IS THE DISTANCE BETWEEN THE FIRST AND SECOND 
<br />SIGNS. THE C DIMENSION IS THE DISTANCE BETWEEN THE SECOND AND THIRD SIGN. (THE THIRD SIGN IS THE 
<br />FIRST ONE IN THE THREE -SIGN SERIES ENCOUNTERED BR A DRIVER APPROACHING A TTC ZONE.) 
<br />SC❑PE ❑F W❑RKI 
<br />THIS TRAFFIC C❑NTR❑L 
<br />R❑AD ENCROACHMENT IN 
<br />PLAN IS F❑R THE FOLLOWING 
<br />SAN J❑AQUIN COUNTY RIGHT OF WAYI 
<br />PLACEMENT ❑F APPROXIMATELY 5000' ❑F NEW CABLE ALONG BEAR CREEK RD 
<br />BETWEEN POLES PA AND P,29, REQUIRING A M❑BILE OPERATI❑N ALONG THE 
<br />LENGTH OF THE ROAD BETWEEN 99 FRONTAGE RD AND N FURRY RD, THIS WORK 
<br />WILL REQUIRE A TEMPORARY (5 MINUTE DURATION) ROAD CLOSURE OF 99 
<br />FRONTAGE RD AT BEAR CREEK RD, FOR THE PLACEMENT OF A NEW SPAN OF 
<br />AERIAL CABLE OVER THE ROADWAY BETWEEN POLES PA AND P,2, AND A 
<br />TEMPORARY ROAD CLOSURE OF N FURRY RD/BEAR CREEK RD FOR THE 
<br />PLACEMENT OF A NEW SPAN OF AERIAL CABLE AND STRAND OVER THE 
<br />ROADWAY BETWEEN POLES P,28 AND P,29, THIS JOB WILL ALSO REQUIRE THE 
<br />REPLACEMENT OF POLES P,12 AND P,27, AND GROUND BED PLACEMENT AT P,24 
<br />(SEE THE ASSOCIATED PERMIT DRAWINGS), 
<br />GENERAL REQUIREMENTSI 
<br />1, ALL TRAFFIC C❑NTR❑L ELEMENTS SHALL COMPLY WITH THE 2019 
<br />CALIFORNIA MANUAL ON UNIFORM TRAFFIC CONTROL DEVICES 
<br /><CA-MUTCD), LATEST EDITION, 
<br />2, TRAFFIC CONTROL ELEMENTS SHOWN ON THE PLAN ARE SCHEMATIC) 
<br />TRAFFIC CONTROL ELEMENTS SHALL BE PLACED IN VISIBLE 
<br />L❑CATIONS WITH SPACING NO LESS THE DIMENSI❑NS SHOWN ON 
<br />THE PLAN, 
<br />3, THE CONTRACTOR SHALL BE RESPONSIBLE FOR MAINTAINING AND 
<br />DOCUMENTING THE INSTALLATI❑N OF TRAFFIC CONTROL ELEMENTS 
<br />AT ALL TIMES, TRAFFIC CONTROL TO REMAIN IN PLACE OVERNIGHT 
<br />SHALL BE LIGHTED OR REFLECTIVE AS REQUIRED BY THE 
<br />CA-MUTCD, 
<br />4, DEVIATI❑NS FROM THE PLAN SHALL BE DOCUMENTED BY THE 
<br />CONTRACTOR AND SUBMITTED TO THE RESIDENT ENGINEER OR 
<br />ENGINEER OF RECORD, 
<br />5, TRAFFIC CONTROL IS DESIGNED FOR A POSTED SPEED OF 35 M,P,H„ 
<br />ONE SPACING SHALL BE NO MORE THAN 25 FEET ON TAPERS AND 
<br />50 FEET ON TANGENTS, 
<br />6, CONTRACT❑R SHALL NOTIFY ALL EMERGENCY RESPONDERS PUBLIC 
<br />TRANSPORTATION PROVIDERS, AND THE CITY REPRESENTATIVES NO 
<br />LESS THAN 48 HOURS PRIOR TO INSTALLATION OF TRAFFIC 
<br />C❑NTR❑L, 
<br />7, CONES SHALL BE NO LESS THAN 28" TALL, 
<br />CONST ARC COMP 
<br />UE29 
<br />EXCH L❑DICA01 � 
<br />ENGRAM❑❑RE TEL (559)454-3826 
<br />ENGR ARC VOKDEEG00 
<br />TYPE ❑F CONST 
<br />TRAFFIC CONTROL PLAN 
<br />RD/ES N❑ A01R1J8 
<br />DWG 1 ❑F 3 P504 
<br />AFL Network 
<br />Services 
<br />A 
<br />Fujikura Business 
<br />THIS JOB WAS ENGINEERED AND DRAWN BY AFL 
<br />NETWORK SERVICES 
<br />UNDER CONTRACT TO AT&T. 
<br />FOR QUESTIONS AND ASSISTANCE ON THIS 
<br />JOB PLEASE CALL ENGINEER AS NOTED IN TITLE BOX. 
<br />UE29 
<br />EXCH L❑DICA01 � 
<br />ENGRAM❑❑RE TEL (559)454-3826 
<br />ENGR ARC VOKDEEG00 
<br />TYPE ❑F CONST 
<br />TRAFFIC CONTROL PLAN 
<br />RD/ES N❑ A01R1J8 
<br />DWG 1 ❑F 3 P504 
<br /> |