My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Permits & Development - Encroachment(EP)/Driveway(DW) Permits - 2020_PS-2000001 thru PS-2000500_ - PS-2000375
PublicWorks
>
- PUBLIC SERVICES
>
PERMITS & DEVELOPMENT
>
Encroachment(EP)/Driveway(DW) Permits
>
2020
>
PS-2000001 thru PS-2000500
>
Permits & Development - Encroachment(EP)/Driveway(DW) Permits - 2020_PS-2000001 thru PS-2000500_ - PS-2000375
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/17/2023 8:41:16 AM
Creation date
4/17/2023 8:39:10 AM
Metadata
Fields
Template:
Permits_Development
DocName
PS-2000375
Category07
Encroachment(EP)/Driveway(DW) Permits
Year2
2020
Notes2
14452 E. Prospect Pl.
Address
2565 Sunnyside Ave., Fresno,CA 93727
Application
Laser Underground Construction
Type
Bell Hole; Bore (up to 12 inch Dia)
Supplemental fields
Cross Ref
PWP7110005
Type (2)
Encroachment Permit (EP)
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
12
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
GENERAL NOTES LINETYPES <br />ALL GENERAL NOTES SHALL APPLY TO ALL DRAWINGS, PLANS AND DETAILS, ---- PROPOSED TRENCH/BORE ROUTE <br />• PROPOSED OVERLASH ROUTE <br />• CONTRACTOR SHALL NOTIFY UNDERGROUND SERVICE ALERT (USA), AT LEAST 48 HOURS PROPOSED OVERPULL ROUTE <br />(AND NOT MORE THAN 14 DAYS) PRIOR TO THE START OF CONSTRUCTION BY CALLING (800) EXISTING LASAR ROUTE <br />227-2600. EXISTING TELEPHONE SYSTEM <br />EXISTING TV SYSTEM <br />• CONTRACTOR SHALL POTHOLE/HAND DIG AND VERIFY ALL UNDERGROUND UTILITIES PRIOR EXISTING GAS SYSTEM <br />TO THE START OF CONSTRUCTION, ALL UTILITY LOCATIONS ON PLANS ARE APPROXIMATE, EXISTING ELECTRICAL SYSTEM <br />CONTRACTOR MUST VERIFY. EXISTING JOINT TRENCH <br />• CONTRACTOR SHALL VERIFY ALL FOOTAGES ON SITE, PRIOR TO THE START OF EXISTING IRRIGATION SYSTEM <br />CONSTRUCTION, ALL DIMENSIONS SHOWN ON PLANS ARE APPROXIMATE. SYMBOLS -' EXISTING SANITARY SEWER <br />EXISTING STORM DRAIN <br />• CONTRACTOR SHALL KEEP A COPY OF APPROVED PLAN(S) AND PERMIT(S) AT THE JOB SITE ® NEW LASAR POWER SUPPLY 0 TRANSFORMER EXISTING WATER LINE <br />AT ALL TIMES AND PRESENT IT TO AN AUTHORIZED AGENT OF THE CITY/COUNTY AND/OR NEW LASAR LOW PROFILE EXISTING FENCELINE <br />LAW ENFORCEMENT UPON REQUEST. STREET LIGHT <br />m I@ POWER SUPPLY W/ METER ROADWAY CENTER LINE <br />- - - - <br />• CONTRACTOR SHALL ENSURE THAT ANY EXISTING FACILITIES DAMAGED OR REMOVED SHALL 0 NEW LASAR VAULT TRAFFIC SIGNAL COMBINATION PROPERTY LINE <br />BE REPLACED IN KIND OR BETTER, INCLUDING BUT NOT LIMITED TO REPLACING EXISTING ,� NEW LASAR PEDESTAL m b FIRE HYDRANT RIGHT OF WAY LINE <br />STRIPING AND REMOVING UNNECESSARY USA!' MARKINGS. ® Q MONUMENT <br />BORE PIT <br />• CONTRACTOR SHALL WORK ONLY DURING APPROVED HOURS, UNLESS OTHERWISE ® CATCH BASIN <br />• <br />APPROVED IN WRITING BY THE "CITY/COUNTY ENGINEER.„ POTHOLE so STORM DRAIN MANHOLE <br />NEW RISER ATTACHED TO POLE <br />• CONTRACTOR SHALL PERFORM ALL WORK AND TRAFFIC CONTROL IN ACCORDANCE WITH Ow WATER MANHOLE <br />THE CITY/COUNTY AND STATE OF CALIFORNIA STANDARD PLANS AND SPECIFICATIONS, AND ® EXISTING POLE <br />CURRENT CALIFORNIA DEPARTMENT OF TRANSPORTATION "MANUAL OF TRAFFIC CONTROLS ED EXISTING LASAR VAULT SANITARY SEWER MANHOLE <br />AND MAINTENANCE OF HAZARD ZONE” AND "MANUAL OF WARNING SIGNS, LIGHTS AND © SEWER CLEAN OUT ABBREVIATIONS <br />DEVICES" FOR USE IN PERFORMANCE OF WORK UPON HIGHWAYS. FLASHING ARROW SIGNS ® EXISTING LASAR PEDESTAL <br />Q ELECTRIC MANHOLE LASAR LASAR PL PROPERTY LINE <br />SHALL BE REQUIRED FOR ALL LANE CLOSURES. o EXISTING IRRIGATION VAULT C/L CENTER LINE PUE PUBLIC UTILITY EASEMENT <br />OO UNIDENTIFIED MANHOLE (E) EXISTING R/W RIGHT OF WAY <br />• CONTRACTOR SHALL ENSURE ALL WORK PERFORMED IS IN ACCORDANCE WITH O EXISTING UTILITY VAULT/PEDESTAL FOC FACE OF CURB SD EXISTING STORM DRAIN <br />® <br />REGULATIONS AND STANDARDS SET BY ANY AND ALL REGULATORY AGENCIES HAVING WATER METER MIN MINIMUM 55 EXISTING SANITARY SEWER <br />pq GAS/WATER VALVE MAX MAXIMUM T EXISTING TELEPHONE <br />JURISDICTION AT THIS WORK SITE, INCLUDING BUT NOT LIMITED TO THE STATE OF n, © GAS METER DWY DRIVEWAY W EXISTING WATER <br />CALIFORNIA PUBLIC UTILITY COMMISSION (CPUC), THE STATE OF CALIFORNIA S ? TREE/BUSHES (N) NEW E EXISTING ELECTRIC <br />OCCUPATIONAL SAFETY AND HEALTH ACT (CAL OSHA), THE COUNTY AND THE CITY. (T) TEMPORARY G EXISTING GAS <br />CNDT CONDUIT <br />• ALL WORK SHALL BE ACCESSIBLE AND SUBJECT TO INSPECTION BY THE CITY/COUNTY <br />ENGINEER AND/OR AN AUTHORIZED AGENT OF COMCAST. <br />• CONTRACTOR SHALL NOTIFY BUSINESS ESTABLISHMENTS/OWNERS AFFECTED BY THE WORK <br />AT LEAST 72 HOURS IN ADVANCE OF CONSTRUCTION. <br />• CONTRACTOR SHALL NOTIFY THE PUBLIC WORKS INSPECTOR 48 HOURS IN ADVANCE OF <br />WORK COMMENCING. <br />THIS IS A LASAR DOCU <br />DESIGN: CITYRISE REV <br />DRAWN BY: <br />APPROVED: <br />APPROVED: <br />APPROVED: <br />PROPRIETARY &CONFIDENTIAL <br />DESCRIPTION DATE <br />IMPORTANT NOTICE <br />Section � 4216/4217 of the Government Code requires a <br />Dig Alert Identification Number to be issued before a <br />"Permit to Excavate" will be valid For your Dig Alert I.D. <br />CALL TOLL FREE <br />48 HOURS BEFORE YOU DIG <br />UNDERGROUND SERVICE ALERT <br />1-800-227-2600 <br />LEGEND, GENERAL NOTES <br />14452 E PROSPECT PL <br />JOB#: 11409825 <br />CONSTRUCTION TYPE: bore <br />SYSTEM: County of San Joaquin <br />NODE: SHEET: CD -O <br />
The URL can be used to link to this page
Your browser does not support the video tag.