Permits & Development - Encroachment(EP)/Driveway(DW) Permits - 2020_PS-2000501 thru PS-2001000_ - PS-2000567
PublicWorks
>
- PUBLIC SERVICES
>
PERMITS & DEVELOPMENT
>
Encroachment(EP)/Driveway(DW) Permits
>
2020
>
PS-2000501 thru PS-2001000
>
Permits & Development - Encroachment(EP)/Driveway(DW) Permits - 2020_PS-2000501 thru PS-2001000_ - PS-2000567
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/17/2023 4:00:09 PM
Creation date
4/17/2023 3:58:27 PM
Metadata
Fields
Template:
Permits_Development
DocName
PS-2000567
Category07
Encroachment(EP)/Driveway(DW) Permits
Year2
2020
Notes2
Waterloo Rd. 330' W/O Filbert St.
Address
4125 Northgate Bl., Sacramento,CA 95834
Application
Tak Communications Ca Inc.
Type
TCP
Supplemental fields
Cross Ref
PWP7110005
Type (2)
Encroachment Permit (EP)
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
10
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
GENERAL NOTE5 LINETYPES <br />•ALL GENERAL NOTES SHALL APPLY TO ALL DRAWINGS, PLANS AND DETAILS. °"�' <br />PROPOSED TRENCH/BORE ROUTE <br />PROPOSED OVERLASH ROUTE <br />CONTRACTOR SHALL NOTIFY UNDERGROUND SERVICE ALERT (USA), AT LEAST 48 HOURS PROPOSED OVERPULL ROUTE <br />• (AND NOT MORE THAN 14 DAYS) PRIOR TO THE START OF CONSTRUCTION BY CALLING (800) EXISTING COMCAST ROUTE <br />227-2600. <br />EXISTING TELEPHONE SYSTEM <br />M <br />SYSTE <br />• CONTRACTOR SHALL POTHOLE/HAND DIG AND VERIFY ALL UNDERGROUND UTILITIES PRIOR EXISTING EXISTING TV TVSSYSTEM <br />SYSTEM <br />TO THE START OF CONSTRUCTION. ALL UTILITY LOCATIONS ON PLANS ARE APPROXIMATE, <br />CONTRACTOR MUST VERIFY. EXISTING ELECTRICAL SYSTEM <br />Jt EXISTING JOINT TRENCH <br />• <br />CONTRACTOR SHALL VERIFY ALL FOOTAGES ON SITE, PRIOR TO THE START OF R' � -� <br />EXISTING IRRIGATION SYSTEM <br />CONSTRUCTION, ALL DIMENSIONS SHOWN ON PLANS ARE APPROXIMATE. SYMBOLS -- _= EXISTING SANITARY SEWER <br />EXISTING STORM DRAIN <br />• CONTRACTOR SHALL KEEP A COPY OF APPROVED PLAN(S) AND PERMIT(S) AT THE JOB SITE NEW COMCAST POWER SUPPLY 0 TRANSFORMER EXISTING WATER LINE <br />AT ALL TIMES AND PRESENT IT TO AN AUTHORIZED AGENT OF THE CITY/COUNTY AND/OR ® NEW COMCAST LOW PROFILE EXISTING FENCELINE <br />LAW ENFORCEMENT UPON REQUEST. �t� m STREET LIGHT ROADWAY CENTER LINE B POWER SUPPLY W/METER <br />Y LINE <br />— — — — RT <br />• CONTRACTOR SHALL ENSURE THAT ANY EXISTING FACILITIES DAMAGED OR REMOVED SHALL O NEW COMCAST VAULT TRAFFIC SIGNAL COMBINATION PROPERTY <br />- RIGHTWAY LINE <br />NEW COMCAST BE REPLACED IN KIND OR BETTER, INCLUDING BUT NOT LIMITED TO REPLACING EXISTING m {5 FIRE HYDRANT <br />STRIPING AND REMOVING UNNECESSARY "USA" MARKINGS. ® Q MONUMENT <br />BORE PIT <br />• CONTRACTOR SHALL WORK ONLY DURING APPROVED HOURS, UNLESS OTHERWISE ® CATCH BASIN <br />APPROVED IN WRITING BY THE "CITY/COUNTY ENGINEER." POTHOLE <br />STORM DRAIN MANHOLE <br />NEW RISER ATTACHED TO POLE <br />• CONTRACTOR SHALL PERFORM ALL WORK AND TRAFFIC CONTROL IN ACCORDANCE WITH ® WATER MANHOLE <br />THE CITY/COUNTY AND STATE OF CALIFORNIA STANDARD PLANS AND SPECIFICATIONS, AND ® EXISTING POLE <br />ss SANITARY SEWER MANHOLE <br />CURRENT CALIFORNIA DEPARTMENT OF TRANSPORTATION "MANUAL OF TRAFFIC CONTROLS EXISTING COMCAST VAULT ABBREVIATIONS <br />AND MAINTENANCE OF HAZARD ZONE" AND "MANUAL OF WARNING SIGNS, LIGHTS AND © SEWER CLEAN OUT <br />DEVICES" FOR USE IN PERFORMANCE OF WORK UPON HIGHWAYS. FLASHING ARROW SIGNS ® EXISTING COMCAST PEDESTAL <br />SHALL BE REQUIRED FOR ALL LANE CLOSURES.® ELECTRIC MANHOLE COMCAST COMCAST PL PROPERTY LINE <br />o EXISTING IRRIGATION VAULT C/L CENTER LINE PUE PUBLIC UTILITY EASEMENT <br />O UNIDENTIFIED MANHOLE (E) EXISTING R/W RIGHT OF WAY <br />• CONTRACTOR SHALL ENSURE ALL WORK PERFORMED IS IN ACCORDANCE WITH O EXISTING UTILITY VAULT/PEDESTAL FOC FACE OF CURB SD EXISTING STORM DRAIN <br />® <br />REGULATIONS AND STANDARDS SET BY ANY AND ALL REGULATORY AGENCIES HAVING WATER METER MIN MINIMUM SS EXISTING SANITARY SEWER <br />pd GAS/WATER VALVE MAX MAXIMUM T EXISTING TELEPHONE <br />JURISDICTION AT THIS WORK SITE, INCLUDING BUT NOT LIMITED TO THE STATE OF © GAS METER DWY DRIVEWAY W EXISTING WATER <br />CALIFORNIA PUBLIC UTILITY COMMISSION (CPUC), THE STATE OF CALIFORNIA TREE/BUSHES (N) NEW E EXISTING ELECTRIC <br />OCCUPATIONAL SAFETY AND HEALTH ACT (CAL OSHA), THE COUNTY AND THE CITY. (T) TEMPORARY G EXISTING GAS <br />CNDT CONDUIT EOP EDGE OF PAVEMENT <br />• ALL WORK SHALL BE ACCESSIBLE AND SUBJECT TO INSPECTION BY THE CITY/COUNTY BOW BACK OF WALK LOG LIP OF GUTTER <br />ENGINEER AND/OR AN AUTHORIZED AGENT OF COMCAST. <br />• CONTRACTOR SHALL NOTIFY BUSINESS ESTABLISHMENTS/OWNERS AFFECTED BY THE WORK <br />AT LEAST 72 HOURS IN ADVANCE OF CONSTRUCTION. <br />• CONTRACTOR SHALL NOTIFY THE PUBLIC WORKS INSPECTOR 48 HOURS IN ADVANCE OF <br />WORK COMMENCING. <br />THIS IS A COMCAST DOCUMENT, PROPRIETARY &CONFIDENTIAL <br />DESIGN: CITYRISE REV DESCRIPTION DATE <br />DRAWN BY: <br />APPROVED: <br />APPROVED: <br />APPROVED: <br />IMPORTANT NOTICE <br />Section � 4216/4217 of the Government Code requires a <br />Dig Alert Identification Number to be Issued before a <br />"Permit to Excavate" will be valid For your Dig Alert I.D. <br />CALL TOLL FREE <br />48 HOURS BEFORE YOU DIG <br />UNDERGROUND SERVICE ALERT <br />1-800-227-2600 <br />JOB#: 195593 <br />CONSTRUCTION TYPE: Aerial <br />SYSTEM: County of San Joaquin <br />NODE: <br />LEGEND, GENERAL NOTES <br />2434 WATERLOO RD <br />SHEET: CD -0 <br />